模拟飞行高度和持续气道正压装置的性能。

Maria Sehlin, Helge Brändström, Ola Winsö, Michael Haney, Karin Wadell, Fredrik Ohberg
{"title":"模拟飞行高度和持续气道正压装置的性能。","authors":"Maria Sehlin,&nbsp;Helge Brändström,&nbsp;Ola Winsö,&nbsp;Michael Haney,&nbsp;Karin Wadell,&nbsp;Fredrik Ohberg","doi":"10.3357/ASEM.4013.2014","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Continuous positive airway pressure (CPAP) is used in air ambulances to treat patients with impaired oxygenation. Differences in mechanical principles between CPAP devices may affect their performance at different ambient air pressures, as will occur in an air ambulance during flight.</p><p><strong>Methods: </strong>Two different CPAP systems, a threshold resistor device and a flow resistor device, at settings of 5 and 10 cm H₂O were examined. Static pressure, static airflow, and pressure during simulated breathing were measured at ground level and at three different altitudes [2400 m (7874 ft), 3000 m (9843 ft), and 10,700 m (35,105 ft)].</p><p><strong>Results: </strong>When altitude increased, the performance of the two CPAP systems differed during both static and simulated breathing pressure measurements. With the threshold resistor CPAP, measured pressure levels were close to the preset CPAP level. Static pressure decreased 0.71 ± 0.35 cm H₂O at CPAP 10 cm H₂O compared to ground level and 35,105 ft (10,700 m). With the flow resistor CPAP, as the altitude increased, CPAP produced pressure levels increased. At 35,105 ft (10,700 m), the increase was 5.13 ± 0.33 cm H₂O at CPAP 10 cm H₂O.</p><p><strong>Discussion: </strong>The velocity of airflow through the flow resistor CPAP device is strongly influenced by reduced ambient air pressure, leading to a higher delivered CPAP effect than the preset CPAP level. Threshold resistor CPAP devices seem to have robust performance regardless of altitude. Thus, the threshold resistor CPAP device is probably more appropriate for CPAP treatment in an air ambulance cabin, where ambient pressure will vary during patient transport.</p>","PeriodicalId":8676,"journal":{"name":"Aviation, space, and environmental medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3357/ASEM.4013.2014","citationCount":"2","resultStr":"{\"title\":\"Simulated flying altitude and performance of continuous positive airway pressure devices.\",\"authors\":\"Maria Sehlin,&nbsp;Helge Brändström,&nbsp;Ola Winsö,&nbsp;Michael Haney,&nbsp;Karin Wadell,&nbsp;Fredrik Ohberg\",\"doi\":\"10.3357/ASEM.4013.2014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Continuous positive airway pressure (CPAP) is used in air ambulances to treat patients with impaired oxygenation. Differences in mechanical principles between CPAP devices may affect their performance at different ambient air pressures, as will occur in an air ambulance during flight.</p><p><strong>Methods: </strong>Two different CPAP systems, a threshold resistor device and a flow resistor device, at settings of 5 and 10 cm H₂O were examined. Static pressure, static airflow, and pressure during simulated breathing were measured at ground level and at three different altitudes [2400 m (7874 ft), 3000 m (9843 ft), and 10,700 m (35,105 ft)].</p><p><strong>Results: </strong>When altitude increased, the performance of the two CPAP systems differed during both static and simulated breathing pressure measurements. With the threshold resistor CPAP, measured pressure levels were close to the preset CPAP level. Static pressure decreased 0.71 ± 0.35 cm H₂O at CPAP 10 cm H₂O compared to ground level and 35,105 ft (10,700 m). With the flow resistor CPAP, as the altitude increased, CPAP produced pressure levels increased. At 35,105 ft (10,700 m), the increase was 5.13 ± 0.33 cm H₂O at CPAP 10 cm H₂O.</p><p><strong>Discussion: </strong>The velocity of airflow through the flow resistor CPAP device is strongly influenced by reduced ambient air pressure, leading to a higher delivered CPAP effect than the preset CPAP level. Threshold resistor CPAP devices seem to have robust performance regardless of altitude. Thus, the threshold resistor CPAP device is probably more appropriate for CPAP treatment in an air ambulance cabin, where ambient pressure will vary during patient transport.</p>\",\"PeriodicalId\":8676,\"journal\":{\"name\":\"Aviation, space, and environmental medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3357/ASEM.4013.2014\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Aviation, space, and environmental medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3357/ASEM.4013.2014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aviation, space, and environmental medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3357/ASEM.4013.2014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

简介:持续气道正压通气(CPAP)用于空中救护车治疗氧合受损患者。CPAP设备之间机械原理的差异可能会影响它们在不同环境气压下的性能,就像飞行中的空中救护车一样。方法:对两种不同的CPAP系统,阈值电阻装置和流量电阻装置,在5和10 cm H₂O的设置下进行了测试。在地面和三个不同高度[2400米(7874英尺)、3000米(9843英尺)和10,700米(35,105英尺)]测量了模拟呼吸期间的静压、静态气流和压力。结果:当海拔升高时,两种CPAP系统在静态和模拟呼吸压力测量中表现不同。使用阈值电阻CPAP,测量的压力水平接近预设的CPAP水平。与地面和35105英尺(10,700米)高度相比,CPAP高度为10 cm H₂O的静压降低了0.71±0.35 cm H₂O。使用流量电阻CPAP时,随着海拔高度的增加,CPAP产生的压力水平也随之增加。在海拔35,105英尺(10,700米)处,当CPAP为10 cm H₂O时,增加了5.13±0.33 cm H₂O。讨论:通过流动电阻CPAP装置的气流速度受到环境气压降低的强烈影响,导致输送的CPAP效果高于预设的CPAP水平。无论海拔高低,阈值电阻CPAP装置似乎都具有稳健的性能。因此,阈值电阻器CPAP装置可能更适合在空中救护舱内进行CPAP治疗,因为在病人运输过程中环境压力会发生变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulated flying altitude and performance of continuous positive airway pressure devices.

Introduction: Continuous positive airway pressure (CPAP) is used in air ambulances to treat patients with impaired oxygenation. Differences in mechanical principles between CPAP devices may affect their performance at different ambient air pressures, as will occur in an air ambulance during flight.

Methods: Two different CPAP systems, a threshold resistor device and a flow resistor device, at settings of 5 and 10 cm H₂O were examined. Static pressure, static airflow, and pressure during simulated breathing were measured at ground level and at three different altitudes [2400 m (7874 ft), 3000 m (9843 ft), and 10,700 m (35,105 ft)].

Results: When altitude increased, the performance of the two CPAP systems differed during both static and simulated breathing pressure measurements. With the threshold resistor CPAP, measured pressure levels were close to the preset CPAP level. Static pressure decreased 0.71 ± 0.35 cm H₂O at CPAP 10 cm H₂O compared to ground level and 35,105 ft (10,700 m). With the flow resistor CPAP, as the altitude increased, CPAP produced pressure levels increased. At 35,105 ft (10,700 m), the increase was 5.13 ± 0.33 cm H₂O at CPAP 10 cm H₂O.

Discussion: The velocity of airflow through the flow resistor CPAP device is strongly influenced by reduced ambient air pressure, leading to a higher delivered CPAP effect than the preset CPAP level. Threshold resistor CPAP devices seem to have robust performance regardless of altitude. Thus, the threshold resistor CPAP device is probably more appropriate for CPAP treatment in an air ambulance cabin, where ambient pressure will vary during patient transport.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Aviation, space, and environmental medicine
Aviation, space, and environmental medicine 医学-公共卫生、环境卫生与职业卫生
自引率
0.00%
发文量
0
审稿时长
1 months
期刊最新文献
Chronic bacterial prostatitis. Carpe diem. Temperature changes in selected areas of body surface induced by systemic cryostimulation. Comparison of in-flight measures with predictions of a bio-mathematical fatigue model. Demographic and occupational predictors of neck pain in pilots: analysis and multinational comparison.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1