Janneke A Cox, Robert L Lukande, Sam Kalungi, Koen Van de Vijver, Eric Van Marck, Ann M Nelson, Asafu Munema, Yukari C Manabe, Robert Colebunders
{"title":"经皮穿刺穿刺尸检的实践一项描述性研究报告了乌干达的经验。","authors":"Janneke A Cox, Robert L Lukande, Sam Kalungi, Koen Van de Vijver, Eric Van Marck, Ann M Nelson, Asafu Munema, Yukari C Manabe, Robert Colebunders","doi":"10.1186/1472-6890-14-44","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Percutaneous needle autopsy can overcome a number of barriers that limit the use of complete autopsies. We performed blind-and ultrasound guided needle autopsies in HIV-infected adults in Uganda. In this study we describe in detail the methods we used, the ability of both procedures to obtain sufficient tissue for further examination and the learning curve of the operators over time.</p><p><strong>Methods: </strong>If written informed consent was granted from the next of kin, we first performed a blind needle autopsy, puncturing brain, heart, lungs, liver, spleen and kidneys using predefined surface marking points. We then performed an ultrasound guided needle autopsy puncturing heart, liver, spleen and kidneys. The number of attempts, expected success and duration of the procedure were noted. A pathologist read the slides and indicated if the target tissue was present and of sufficient quality for pathological review. We report the predicted and true success rates, compare the yield of blind to ultrasound guided needle biopsies and evaluate the failure rate over time.</p><p><strong>Results: </strong>Two operators performed 96 blind needle autopsies and 95 ultrasound guided needle autopsies. For blind needle biopsies true success rates varied from 56-99% and predicted success rates from 89-99%. For ultrasound guided needle biopsies true success rates varied from 72-100% and predicted success rates from 84-98%. Ultrasound guidance led to a significantly higher success rate in heart and left kidney. A learning curve was observed over time with decreasing failure rates with increasing experience and a shorter duration of the needle autopsy.</p><p><strong>Conclusion: </strong>Needle autopsy can successfully obtain tissue for further pathological review in the vast majority of cases, with a decrease in failure rate with increasing experience of the operator. The benefit of ultrasound guidance will depend on the population, the disease and organ of interest and the local circumstances. Our results justify further evaluation of needle autopsies as a method to establish a cause of death.</p>","PeriodicalId":35804,"journal":{"name":"BMC Clinical Pathology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/1472-6890-14-44","citationCount":"22","resultStr":"{\"title\":\"Practice of percutaneous needle autopsy; a descriptive study reporting experiences from Uganda.\",\"authors\":\"Janneke A Cox, Robert L Lukande, Sam Kalungi, Koen Van de Vijver, Eric Van Marck, Ann M Nelson, Asafu Munema, Yukari C Manabe, Robert Colebunders\",\"doi\":\"10.1186/1472-6890-14-44\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Percutaneous needle autopsy can overcome a number of barriers that limit the use of complete autopsies. We performed blind-and ultrasound guided needle autopsies in HIV-infected adults in Uganda. In this study we describe in detail the methods we used, the ability of both procedures to obtain sufficient tissue for further examination and the learning curve of the operators over time.</p><p><strong>Methods: </strong>If written informed consent was granted from the next of kin, we first performed a blind needle autopsy, puncturing brain, heart, lungs, liver, spleen and kidneys using predefined surface marking points. We then performed an ultrasound guided needle autopsy puncturing heart, liver, spleen and kidneys. The number of attempts, expected success and duration of the procedure were noted. A pathologist read the slides and indicated if the target tissue was present and of sufficient quality for pathological review. We report the predicted and true success rates, compare the yield of blind to ultrasound guided needle biopsies and evaluate the failure rate over time.</p><p><strong>Results: </strong>Two operators performed 96 blind needle autopsies and 95 ultrasound guided needle autopsies. For blind needle biopsies true success rates varied from 56-99% and predicted success rates from 89-99%. For ultrasound guided needle biopsies true success rates varied from 72-100% and predicted success rates from 84-98%. Ultrasound guidance led to a significantly higher success rate in heart and left kidney. A learning curve was observed over time with decreasing failure rates with increasing experience and a shorter duration of the needle autopsy.</p><p><strong>Conclusion: </strong>Needle autopsy can successfully obtain tissue for further pathological review in the vast majority of cases, with a decrease in failure rate with increasing experience of the operator. The benefit of ultrasound guidance will depend on the population, the disease and organ of interest and the local circumstances. Our results justify further evaluation of needle autopsies as a method to establish a cause of death.</p>\",\"PeriodicalId\":35804,\"journal\":{\"name\":\"BMC Clinical Pathology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/1472-6890-14-44\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Clinical Pathology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/1472-6890-14-44\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2014/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Clinical Pathology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/1472-6890-14-44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Practice of percutaneous needle autopsy; a descriptive study reporting experiences from Uganda.
Background: Percutaneous needle autopsy can overcome a number of barriers that limit the use of complete autopsies. We performed blind-and ultrasound guided needle autopsies in HIV-infected adults in Uganda. In this study we describe in detail the methods we used, the ability of both procedures to obtain sufficient tissue for further examination and the learning curve of the operators over time.
Methods: If written informed consent was granted from the next of kin, we first performed a blind needle autopsy, puncturing brain, heart, lungs, liver, spleen and kidneys using predefined surface marking points. We then performed an ultrasound guided needle autopsy puncturing heart, liver, spleen and kidneys. The number of attempts, expected success and duration of the procedure were noted. A pathologist read the slides and indicated if the target tissue was present and of sufficient quality for pathological review. We report the predicted and true success rates, compare the yield of blind to ultrasound guided needle biopsies and evaluate the failure rate over time.
Results: Two operators performed 96 blind needle autopsies and 95 ultrasound guided needle autopsies. For blind needle biopsies true success rates varied from 56-99% and predicted success rates from 89-99%. For ultrasound guided needle biopsies true success rates varied from 72-100% and predicted success rates from 84-98%. Ultrasound guidance led to a significantly higher success rate in heart and left kidney. A learning curve was observed over time with decreasing failure rates with increasing experience and a shorter duration of the needle autopsy.
Conclusion: Needle autopsy can successfully obtain tissue for further pathological review in the vast majority of cases, with a decrease in failure rate with increasing experience of the operator. The benefit of ultrasound guidance will depend on the population, the disease and organ of interest and the local circumstances. Our results justify further evaluation of needle autopsies as a method to establish a cause of death.
期刊介绍:
BMC Clinical Pathology is an open access journal publishing original peer-reviewed research articles in all aspects of histopathology, haematology, clinical biochemistry, and medical microbiology (including virology, parasitology, and infection control). BMC Clinical Pathology (ISSN 1472-6890) is indexed/tracked/covered by PubMed, CAS, EMBASE, Scopus and Google Scholar.