骶髂关节运动和骨盆关节融合结果的放射立体分析。

Thomas Johan Kibsgård
{"title":"骶髂关节运动和骨盆关节融合结果的放射立体分析。","authors":"Thomas Johan Kibsgård","doi":"10.3109/17453674.2015.1022707","DOIUrl":null,"url":null,"abstract":"Background Different techniques have been used to quantify the movement of sacroiliac (SI) joints. These include radiostereometric analysis (RSA), but the accuracy and precision of this method have not been properly evaluated and it is unclear how many markers are required and where they should be placed to achieve proper accuracy and precision. Purpose The purpose of this study was to test accuracy and precision of RSA, applied to the SI joint, in a phantom model and in patients. Methods We used a plastic phantom attached to a micrometer to obtain a true value of the movement of the SI joint and compared this value with the measured value obtained by RSA; the difference represented the accuracy. The precision of the system was measured by double examination in the phantom and in six patients, and was expressed by a limit of significance (LOS). We analyzed different marker distributions to find optimal marker placement and number of markers needed. Results The accuracy was high and we identified no systematic errors. The precision of the phantom was high with a LOS less than 0.25 and 0.16 mm for all directions, and in patients, the precision was less than 0.71 for rotations and 0.47 mm translations. No markers were needed in the pubic symphysis to obtain good precision. Conclusions The accuracy and precision are high when RSA is used to measure movement in the SI joint and support the use of RSA in research of SI joint motion.","PeriodicalId":87168,"journal":{"name":"Acta orthopaedica. Supplementum","volume":"86 359","pages":"1-43"},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/17453674.2015.1022707","citationCount":"9","resultStr":"{\"title\":\"Radiostereometric analysis of sacroiliac joint movement and outcomes of pelvic joint fusion.\",\"authors\":\"Thomas Johan Kibsgård\",\"doi\":\"10.3109/17453674.2015.1022707\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background Different techniques have been used to quantify the movement of sacroiliac (SI) joints. These include radiostereometric analysis (RSA), but the accuracy and precision of this method have not been properly evaluated and it is unclear how many markers are required and where they should be placed to achieve proper accuracy and precision. Purpose The purpose of this study was to test accuracy and precision of RSA, applied to the SI joint, in a phantom model and in patients. Methods We used a plastic phantom attached to a micrometer to obtain a true value of the movement of the SI joint and compared this value with the measured value obtained by RSA; the difference represented the accuracy. The precision of the system was measured by double examination in the phantom and in six patients, and was expressed by a limit of significance (LOS). We analyzed different marker distributions to find optimal marker placement and number of markers needed. Results The accuracy was high and we identified no systematic errors. The precision of the phantom was high with a LOS less than 0.25 and 0.16 mm for all directions, and in patients, the precision was less than 0.71 for rotations and 0.47 mm translations. No markers were needed in the pubic symphysis to obtain good precision. Conclusions The accuracy and precision are high when RSA is used to measure movement in the SI joint and support the use of RSA in research of SI joint motion.\",\"PeriodicalId\":87168,\"journal\":{\"name\":\"Acta orthopaedica. Supplementum\",\"volume\":\"86 359\",\"pages\":\"1-43\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/17453674.2015.1022707\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica. Supplementum\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/17453674.2015.1022707\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica. Supplementum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/17453674.2015.1022707","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Radiostereometric analysis of sacroiliac joint movement and outcomes of pelvic joint fusion.
Background Different techniques have been used to quantify the movement of sacroiliac (SI) joints. These include radiostereometric analysis (RSA), but the accuracy and precision of this method have not been properly evaluated and it is unclear how many markers are required and where they should be placed to achieve proper accuracy and precision. Purpose The purpose of this study was to test accuracy and precision of RSA, applied to the SI joint, in a phantom model and in patients. Methods We used a plastic phantom attached to a micrometer to obtain a true value of the movement of the SI joint and compared this value with the measured value obtained by RSA; the difference represented the accuracy. The precision of the system was measured by double examination in the phantom and in six patients, and was expressed by a limit of significance (LOS). We analyzed different marker distributions to find optimal marker placement and number of markers needed. Results The accuracy was high and we identified no systematic errors. The precision of the phantom was high with a LOS less than 0.25 and 0.16 mm for all directions, and in patients, the precision was less than 0.71 for rotations and 0.47 mm translations. No markers were needed in the pubic symphysis to obtain good precision. Conclusions The accuracy and precision are high when RSA is used to measure movement in the SI joint and support the use of RSA in research of SI joint motion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Internal fixation of fragility fractures of the femoral neck. The young osteoarthritic hip: Clinical outcome of total hip arthroplasty and a cost-effectiveness analysis. Radiostereometric analysis of sacroiliac joint movement and outcomes of pelvic joint fusion. Complications in ankle fracture surgery. Determinants of outcome in lumbar spinal stenosis surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1