{"title":"前列腺活检的长度不一定会受到一个石蜡块中汇集多个核心的损害:一项观察性研究。","authors":"Teemu T Tolonen,&nbsp;Jorma Isola,&nbsp;Antti Kaipia,&nbsp;Jarno Riikonen,&nbsp;Laura Koivusalo,&nbsp;Sanna Huovinen,&nbsp;Marita Laurila,&nbsp;Sinikka Porre,&nbsp;Mika Tirkkonen,&nbsp;Paula Kujala","doi":"10.1186/s12907-015-0001-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Individually submitted prostatic needle biopsies are recommended by most guidelines because of their potential advantage in terms of core quality. However, unspecified bilateral biopsies are commonly submitted in many centers. The length of the core is the key quality indicator of prostate biopsies. Because there are few recent publications comparing the quality of 12 site-designated biopsies versus pooled biopsies, we compared the lengths of the biopsies obtained by both methods.</p><p><strong>Methods: </strong>The material was obtained from 471 consecutive subjects who underwent prostatic needle biopsy in the Tampere University Hospital district between January and June 2013. Biopsies from 344 subjects fulfilled the inclusion criteria. The total number of cores obtained was 4047. The core lengths were measured on microscope slides. Extraprostatic tissue was subtracted from the core length.</p><p><strong>Results: </strong>The aggregate lengths observed were 129.5 ± 21.8 mm (mean ± SD) for site-designated cores and 136.9 ± 26.4 mm for pooled cores (p = 0.09). The length of the core was 10.8 ± 1.8 mm for site-designated cores and 11.4 ± 2.2 mm for pooled cores (p = 0.87). The median length for pooled cores was 11 mm (range 5 mm - 18 mm). For individual site-designated cores, the median length was 11 mm (range 7 mm -15 mm). The core length was not correlated with the number of cores embedded into one paraffin block (r = 0.015). There was no significant difference in cancer detection rate (p = 0.62).</p><p><strong>Conclusions: </strong>Our results suggest that unspecified bilateral biopsies do not automatically lead to reduced core length. We conclude that carefully embedded multiple (three to nine) cores per block may yield cores of equal quality in a more cost-efficient way and that current guidelines favoring individually submitted cores may be too strict.</p>","PeriodicalId":35804,"journal":{"name":"BMC Clinical Pathology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s12907-015-0001-9","citationCount":"6","resultStr":"{\"title\":\"Length of prostate biopsies is not necessarily compromised by pooling multiple cores in one paraffin block: an observational study.\",\"authors\":\"Teemu T Tolonen,&nbsp;Jorma Isola,&nbsp;Antti Kaipia,&nbsp;Jarno Riikonen,&nbsp;Laura Koivusalo,&nbsp;Sanna Huovinen,&nbsp;Marita Laurila,&nbsp;Sinikka Porre,&nbsp;Mika Tirkkonen,&nbsp;Paula Kujala\",\"doi\":\"10.1186/s12907-015-0001-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Individually submitted prostatic needle biopsies are recommended by most guidelines because of their potential advantage in terms of core quality. However, unspecified bilateral biopsies are commonly submitted in many centers. The length of the core is the key quality indicator of prostate biopsies. Because there are few recent publications comparing the quality of 12 site-designated biopsies versus pooled biopsies, we compared the lengths of the biopsies obtained by both methods.</p><p><strong>Methods: </strong>The material was obtained from 471 consecutive subjects who underwent prostatic needle biopsy in the Tampere University Hospital district between January and June 2013. Biopsies from 344 subjects fulfilled the inclusion criteria. The total number of cores obtained was 4047. The core lengths were measured on microscope slides. Extraprostatic tissue was subtracted from the core length.</p><p><strong>Results: </strong>The aggregate lengths observed were 129.5 ± 21.8 mm (mean ± SD) for site-designated cores and 136.9 ± 26.4 mm for pooled cores (p = 0.09). The length of the core was 10.8 ± 1.8 mm for site-designated cores and 11.4 ± 2.2 mm for pooled cores (p = 0.87). The median length for pooled cores was 11 mm (range 5 mm - 18 mm). For individual site-designated cores, the median length was 11 mm (range 7 mm -15 mm). The core length was not correlated with the number of cores embedded into one paraffin block (r = 0.015). There was no significant difference in cancer detection rate (p = 0.62).</p><p><strong>Conclusions: </strong>Our results suggest that unspecified bilateral biopsies do not automatically lead to reduced core length. We conclude that carefully embedded multiple (three to nine) cores per block may yield cores of equal quality in a more cost-efficient way and that current guidelines favoring individually submitted cores may be too strict.</p>\",\"PeriodicalId\":35804,\"journal\":{\"name\":\"BMC Clinical Pathology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s12907-015-0001-9\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMC Clinical Pathology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s12907-015-0001-9\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Clinical Pathology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s12907-015-0001-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 6

摘要

背景:大多数指南推荐单独提交的前列腺穿刺活检,因为它们在核心质量方面具有潜在的优势。然而,许多中心通常会提交未明确的双侧活检。核心的长度是前列腺活检的关键质量指标。由于很少有最近的出版物比较12点指定活检和集合活检的质量,我们比较了两种方法获得的活检的长度。方法:资料来自2013年1月至6月在坦佩雷大学医院区连续行前列腺穿刺活检的471例受试者。344名受试者的活组织检查符合纳入标准。获得的总核数为4047。在显微镜载玻片上测量芯的长度。从核心长度中减去前列腺外组织。结果:定点岩心的骨料长度为129.5±21.8 mm(平均±SD),集合岩心的骨料长度为136.9±26.4 mm (p = 0.09)。定点岩心长度为10.8±1.8 mm,集合岩心长度为11.4±2.2 mm (p = 0.87)。池芯的中位长度为11毫米(范围为5毫米- 18毫米)。对于单个站点指定的岩心,中位长度为11毫米(范围为7毫米-15毫米)。岩心长度与单个石蜡块内嵌岩心数量无关(r = 0.015)。两组肿瘤检出率差异无统计学意义(p = 0.62)。结论:我们的结果表明,未明确的双侧活检不会自动导致核心长度减少。我们得出的结论是,每块仔细嵌入多个(3到9个)内核可能以更经济有效的方式产生相同质量的内核,并且当前的指导方针倾向于单独提交内核可能过于严格。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Length of prostate biopsies is not necessarily compromised by pooling multiple cores in one paraffin block: an observational study.

Background: Individually submitted prostatic needle biopsies are recommended by most guidelines because of their potential advantage in terms of core quality. However, unspecified bilateral biopsies are commonly submitted in many centers. The length of the core is the key quality indicator of prostate biopsies. Because there are few recent publications comparing the quality of 12 site-designated biopsies versus pooled biopsies, we compared the lengths of the biopsies obtained by both methods.

Methods: The material was obtained from 471 consecutive subjects who underwent prostatic needle biopsy in the Tampere University Hospital district between January and June 2013. Biopsies from 344 subjects fulfilled the inclusion criteria. The total number of cores obtained was 4047. The core lengths were measured on microscope slides. Extraprostatic tissue was subtracted from the core length.

Results: The aggregate lengths observed were 129.5 ± 21.8 mm (mean ± SD) for site-designated cores and 136.9 ± 26.4 mm for pooled cores (p = 0.09). The length of the core was 10.8 ± 1.8 mm for site-designated cores and 11.4 ± 2.2 mm for pooled cores (p = 0.87). The median length for pooled cores was 11 mm (range 5 mm - 18 mm). For individual site-designated cores, the median length was 11 mm (range 7 mm -15 mm). The core length was not correlated with the number of cores embedded into one paraffin block (r = 0.015). There was no significant difference in cancer detection rate (p = 0.62).

Conclusions: Our results suggest that unspecified bilateral biopsies do not automatically lead to reduced core length. We conclude that carefully embedded multiple (three to nine) cores per block may yield cores of equal quality in a more cost-efficient way and that current guidelines favoring individually submitted cores may be too strict.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMC Clinical Pathology
BMC Clinical Pathology Medicine-Pathology and Forensic Medicine
CiteScore
3.30
自引率
0.00%
发文量
0
期刊介绍: BMC Clinical Pathology is an open access journal publishing original peer-reviewed research articles in all aspects of histopathology, haematology, clinical biochemistry, and medical microbiology (including virology, parasitology, and infection control). BMC Clinical Pathology (ISSN 1472-6890) is indexed/tracked/covered by PubMed, CAS, EMBASE, Scopus and Google Scholar.
期刊最新文献
Epidemiological and histopathological profile of malignant melanoma in Malawi. Reference intervals for serum cystatin C and serum creatinine in an adult sub-Saharan African population. Clinical significance of HER2 and EGFR expression in colorectal cancer patients with ovarian metastasis. Accidental intoxications in toddlers: lack of cross-reactivity of vilazodone and its urinary metabolite M17 with drug of abuse screening immunoassays. HER2 overexpression and correlation with other significant clinicopathologic parameters in Ivorian breast cancer women.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1