{"title":"VivaSight单腔管联合高角度视频喉镜检查抢救Goldenhar综合征气管插管失败1例报告。","authors":"Emma Möhlenkamp,&nbsp;Eva K Kohse,&nbsp;Phillip B Sasu,&nbsp;Tanja Peters,&nbsp;Jörn Grensemann,&nbsp;Philipp Breitfeld,&nbsp;Martin Petzoldt","doi":"10.1213/XAA.0000000000001615","DOIUrl":null,"url":null,"abstract":"<p><p>This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.</p>","PeriodicalId":7307,"journal":{"name":"A&A Practice","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2022-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"VivaSight Single-Lumen Tube Combined With Hyperangulated Videolaryngoscopy to Rescue Failed Tracheal Intubation in a Patient With Goldenhar Syndrome: A Case Report.\",\"authors\":\"Emma Möhlenkamp,&nbsp;Eva K Kohse,&nbsp;Phillip B Sasu,&nbsp;Tanja Peters,&nbsp;Jörn Grensemann,&nbsp;Philipp Breitfeld,&nbsp;Martin Petzoldt\",\"doi\":\"10.1213/XAA.0000000000001615\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.</p>\",\"PeriodicalId\":7307,\"journal\":{\"name\":\"A&A Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-09-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"A&A Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1213/XAA.0000000000001615\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/9/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"A&A Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1213/XAA.0000000000001615","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本报告描述了一例接受麻醉的Goldenhar综合征患者,Macintosh视频喉镜检查失败,因为会咽粘附在后咽上,无法用气管引入器提起(Cormack-Lehane分级3B)。即使在直接提起会厌后,高角度的视频喉镜检查也只显示了类甲状腺(Cormack-Lehane分级2B),由于组织阻力不明,气管内管推进失败。高角度视频喉镜检查与安装在管内的摄像机(VivaSight单腔管)相结合。两种视角的结合被成功地用于将气管内管放置在会厌下方并穿过声带。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
VivaSight Single-Lumen Tube Combined With Hyperangulated Videolaryngoscopy to Rescue Failed Tracheal Intubation in a Patient With Goldenhar Syndrome: A Case Report.

This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
A&A Practice
A&A Practice ANESTHESIOLOGY-
自引率
0.00%
发文量
0
期刊介绍: A & A Case Reports, our new online journal publishing Case Reports, related Editorial Commentary, and Correspondence. Anesthesia & Analgesia 1 and Anesthesiology 2 recently announced that they were suspending publication of Case Reports. One reason is that Case Reports typically reduce the Impact Factor of a journal because they are rarely cited. Regardless of the merits of Impact Factor as a metric of journal worth, journals and their editors necessarily consider Impact Factor in strategic planning. At the same time, Case Reports are appreciated by readers for describing “real life” management of difficult or unusual cases not often encountered by practitioners. In a recent issue of Anesthesia & Analgesia, Steven Shafer1 identified many Case Reports whose publication launched productive careers dedicated to solving the puzzle posed by an unusual observation in a single patient.
期刊最新文献
Pediatric Renal Transplant With Dilated Cardiomyopathy: A Stepwise Hemodynamic Management-A Case Report. Undiagnosed Factor VII Deficiency in Cardiac Surgery Complicated by Bleeding: A Case Report. Auto-Brewery Syndrome and General Anesthesia: A Case Report. Perioperative Autonomic Dysfunction in a Patient With Charcot-Marie-Tooth Disease: A Case Report. The Quality Improvement Fellow: Educating on Making the Difference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1