锥形和圆柱形种植体中平台切换对嵴骨应力的评估:有限元分析。

Amir Alireza Rasouli-Ghahroudi, Allahyar Geramy, Siamak Yaghobee, Afshin Khorsand, Hosnieh Yousefifakhr, Amirreza Rokn, Ahmad Soolari
{"title":"锥形和圆柱形种植体中平台切换对嵴骨应力的评估:有限元分析。","authors":"Amir Alireza Rasouli-Ghahroudi,&nbsp;Allahyar Geramy,&nbsp;Siamak Yaghobee,&nbsp;Afshin Khorsand,&nbsp;Hosnieh Yousefifakhr,&nbsp;Amirreza Rokn,&nbsp;Ahmad Soolari","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To analyze and compare the stress distribution around tapered and cylindrical implants and investigate how different abutment diameters influence crestal bone stress levels.</p><p><strong>Materials and methods: </strong>Six finite element models of an abutment (5 mm, 4.3 mm, and 3.5 mm in diameter) and supporting implants (tapered and cylindrical) were designed. A vertical force of 100 N and a 15-degree oblique force of 100 N were applied separately on the occlusal surface, and von Misses stresses were evaluated in the cortical and cancellous bone.</p><p><strong>Results: </strong>Higher stress was observed under oblique loading than under vertical loading of both tapered and cylindrical implants. Tapered implants demonstrated more stress under both vertical and oblique loading. Platform switching reduced peri-implant crestal bone stress in all models under vertical and oblique forces. The peri-implant crestal bone around tapered implants experienced 4.8% more stress under vertical loading and 35% more stress under oblique loading in comparison to bone around cylindrical implants (2.62 MPa with vertical loading, 8.11 MPa under oblique loading). Oblique loads resulted in much higher stress concentrations in the peri-implant crestal bone than vertical loads (238% in cylindrical and 308% in tapered implants). When the abutment diameter decreased, both models showed reductions of stress in the crestal bone under both types of loading.</p><p><strong>Conclusion: </strong>In this finite element analysis, tapered implants increased crestal bone stress upon loading, and platform switching minimized the stress transmitted to the crestal bone in both tapered and parallel wall implants.</p>","PeriodicalId":17281,"journal":{"name":"Journal of the International Academy of Periodontology","volume":"17 1","pages":"2-13"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis.\",\"authors\":\"Amir Alireza Rasouli-Ghahroudi,&nbsp;Allahyar Geramy,&nbsp;Siamak Yaghobee,&nbsp;Afshin Khorsand,&nbsp;Hosnieh Yousefifakhr,&nbsp;Amirreza Rokn,&nbsp;Ahmad Soolari\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To analyze and compare the stress distribution around tapered and cylindrical implants and investigate how different abutment diameters influence crestal bone stress levels.</p><p><strong>Materials and methods: </strong>Six finite element models of an abutment (5 mm, 4.3 mm, and 3.5 mm in diameter) and supporting implants (tapered and cylindrical) were designed. A vertical force of 100 N and a 15-degree oblique force of 100 N were applied separately on the occlusal surface, and von Misses stresses were evaluated in the cortical and cancellous bone.</p><p><strong>Results: </strong>Higher stress was observed under oblique loading than under vertical loading of both tapered and cylindrical implants. Tapered implants demonstrated more stress under both vertical and oblique loading. Platform switching reduced peri-implant crestal bone stress in all models under vertical and oblique forces. The peri-implant crestal bone around tapered implants experienced 4.8% more stress under vertical loading and 35% more stress under oblique loading in comparison to bone around cylindrical implants (2.62 MPa with vertical loading, 8.11 MPa under oblique loading). Oblique loads resulted in much higher stress concentrations in the peri-implant crestal bone than vertical loads (238% in cylindrical and 308% in tapered implants). When the abutment diameter decreased, both models showed reductions of stress in the crestal bone under both types of loading.</p><p><strong>Conclusion: </strong>In this finite element analysis, tapered implants increased crestal bone stress upon loading, and platform switching minimized the stress transmitted to the crestal bone in both tapered and parallel wall implants.</p>\",\"PeriodicalId\":17281,\"journal\":{\"name\":\"Journal of the International Academy of Periodontology\",\"volume\":\"17 1\",\"pages\":\"2-13\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the International Academy of Periodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Academy of Periodontology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:分析比较锥形种植体和圆柱形种植体周围的应力分布,探讨不同基牙直径对冠骨应力水平的影响。材料与方法:设计了6个基台(直径5mm、4.3 mm和3.5 mm)和支撑种植体(锥形和圆柱形)的有限元模型。在咬合表面分别施加100 N的垂直力和100 N的15度斜向力,并在皮质骨和松质骨中评估von mises应力。结果:锥形种植体和圆柱形种植体在倾斜载荷下的应力均高于垂直载荷下的应力。锥形种植体在垂直和斜向载荷下均表现出更大的应力。在垂直和斜向力作用下,平台切换降低了所有模型种植体周围嵴骨应力。与圆柱形种植体相比,锥形种植体周围的种植体嵴骨在垂直加载下承受的应力增加4.8%,在倾斜加载下承受的应力增加35%(垂直加载为2.62 MPa,倾斜加载为8.11 MPa)。斜向载荷导致种植体周围嵴骨的应力浓度比垂直载荷高得多(圆柱形种植体为238%,锥形种植体为308%)。两种载荷下,当基牙直径减小时,两种模型的冠骨应力均有所减小。结论:在本有限元分析中,锥形种植体在加载时增加了牙冠骨的应力,平台切换最小化了锥形种植体和平行壁种植体传递到牙冠骨的应力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Platform Switching on Crestal Bone Stress in Tapered and Cylindrical Implants: A Finite Element Analysis.

Purpose: To analyze and compare the stress distribution around tapered and cylindrical implants and investigate how different abutment diameters influence crestal bone stress levels.

Materials and methods: Six finite element models of an abutment (5 mm, 4.3 mm, and 3.5 mm in diameter) and supporting implants (tapered and cylindrical) were designed. A vertical force of 100 N and a 15-degree oblique force of 100 N were applied separately on the occlusal surface, and von Misses stresses were evaluated in the cortical and cancellous bone.

Results: Higher stress was observed under oblique loading than under vertical loading of both tapered and cylindrical implants. Tapered implants demonstrated more stress under both vertical and oblique loading. Platform switching reduced peri-implant crestal bone stress in all models under vertical and oblique forces. The peri-implant crestal bone around tapered implants experienced 4.8% more stress under vertical loading and 35% more stress under oblique loading in comparison to bone around cylindrical implants (2.62 MPa with vertical loading, 8.11 MPa under oblique loading). Oblique loads resulted in much higher stress concentrations in the peri-implant crestal bone than vertical loads (238% in cylindrical and 308% in tapered implants). When the abutment diameter decreased, both models showed reductions of stress in the crestal bone under both types of loading.

Conclusion: In this finite element analysis, tapered implants increased crestal bone stress upon loading, and platform switching minimized the stress transmitted to the crestal bone in both tapered and parallel wall implants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Periodontal status in cannabis smokers. A systematic review. Impact of Subepithelial Connective Tissue for Root Coverage on Brazilian Patients' Quality of Life: A Longitudinal Clinical Study. Coefficient of variation of red cell distribution width has correlations to periodontal inflamed surface area in non-obese hypertensive patients. Immediate implant placement in periodontally infected sites- A systematic review and meta-analysis. Chitosan-based biomaterial and hyaluronic acid on the repair of intrabuccal bone defects in rats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1