{"title":"三种烧瓶封口方法对上颌义齿线性尺寸精度的比较。一项体外研究。","authors":"P Pachauri,&nbsp;R Sangur,&nbsp;L Rao Bathala,&nbsp;T Mahajan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This laboratory study conducted to evaluate and compare the influence of different flask closure methods on linear dimensional changes of standardized simulated maxillary complete dentures.</p><p><strong>Materials and methods: </strong>Thirty casts were made from a silicone mold representing an edentulous maxillary arch. Thirty identical maxillary dentures were made and randomly assigned to 3 test groups (A, B, C). In Group A, flasks were placed directly in pressure clamp after trial closure. Group B: The final closure was done in a hydraulic press then transferred to pressure clamp. Group C: After trial closure flask was positioned between the two iron plates of the Restriction System flask closure (RSFC) method. Then linear distances were measured three times before and after polymerization: right incisor to left incisor (RI-LI), right premolar to left premolar (RPM-LPM), right molar to left molar (RM-LM) and left incisor- to- left molar (LI-LM) and right incisor- to- right molar (RI-RM) with the help of digital caliper with an accuracy of 0.01mm. ANOVA and Tuckey's test were used to compare the groups (p < 0.05).</p><p><strong>Results: </strong>Inter molar (LM-RM) width showed the greatest dimensional change after processing and Linear dimensions were not significantly influenced by the packing procedure.</p><p><strong>Conclusion: </strong>Within the limitations of this study, Restriction System flask closure (RSFC) method demonstrated a similar performance in reducing the tooth movement when compared with other flask closure methods. The posterior region of the denture may present changes in the tooth position after processing, which need to be clinically adjusted.</p>","PeriodicalId":76278,"journal":{"name":"Odonto-stomatologie tropicale = Tropical dental journal","volume":"39 153","pages":"14-22"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of the linear dimensional accuracy of the maxillary denture teeth by three flask closure methods. An in vitro study.\",\"authors\":\"P Pachauri,&nbsp;R Sangur,&nbsp;L Rao Bathala,&nbsp;T Mahajan\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This laboratory study conducted to evaluate and compare the influence of different flask closure methods on linear dimensional changes of standardized simulated maxillary complete dentures.</p><p><strong>Materials and methods: </strong>Thirty casts were made from a silicone mold representing an edentulous maxillary arch. Thirty identical maxillary dentures were made and randomly assigned to 3 test groups (A, B, C). In Group A, flasks were placed directly in pressure clamp after trial closure. Group B: The final closure was done in a hydraulic press then transferred to pressure clamp. Group C: After trial closure flask was positioned between the two iron plates of the Restriction System flask closure (RSFC) method. Then linear distances were measured three times before and after polymerization: right incisor to left incisor (RI-LI), right premolar to left premolar (RPM-LPM), right molar to left molar (RM-LM) and left incisor- to- left molar (LI-LM) and right incisor- to- right molar (RI-RM) with the help of digital caliper with an accuracy of 0.01mm. ANOVA and Tuckey's test were used to compare the groups (p < 0.05).</p><p><strong>Results: </strong>Inter molar (LM-RM) width showed the greatest dimensional change after processing and Linear dimensions were not significantly influenced by the packing procedure.</p><p><strong>Conclusion: </strong>Within the limitations of this study, Restriction System flask closure (RSFC) method demonstrated a similar performance in reducing the tooth movement when compared with other flask closure methods. The posterior region of the denture may present changes in the tooth position after processing, which need to be clinically adjusted.</p>\",\"PeriodicalId\":76278,\"journal\":{\"name\":\"Odonto-stomatologie tropicale = Tropical dental journal\",\"volume\":\"39 153\",\"pages\":\"14-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Odonto-stomatologie tropicale = Tropical dental journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Odonto-stomatologie tropicale = Tropical dental journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价和比较不同烧瓶封口方式对标准化模拟上颌全口义齿线性尺寸变化的影响。材料和方法:用硅胶模具制作30个铸型,代表无牙颌弓。制作30个相同的上颌义齿,随机分为3个实验组(A、B、C)。A组在试合后将烧瓶直接置于压力钳中。B组:最后闭合在液压机中完成,然后转移到压力钳。C组:试封后的烧瓶放置在限制系统烧瓶封法(RSFC)的两块铁板之间。然后用数字卡尺测量聚合前后3次直线距离:右门牙到左门牙(RI-LI)、右前臼齿到左前臼齿(RPM-LPM)、右臼齿到左臼齿(RM-LM)、左门牙到左臼齿(LI-LM)和右门牙到右臼齿(RI-RM),精度为0.01mm。各组间比较采用方差分析和Tuckey检验(p < 0.05)。结果:加工后磨牙间(LM-RM)尺寸变化最大,包装工艺对线性尺寸影响不显著。结论:在本研究的局限性内,限制系统烧瓶封闭(RSFC)方法与其他烧瓶封闭方法相比,在减少牙齿运动方面表现出相似的性能。义齿加工后后牙区可能出现牙位变化,需要临床调整。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of the linear dimensional accuracy of the maxillary denture teeth by three flask closure methods. An in vitro study.

Purpose: This laboratory study conducted to evaluate and compare the influence of different flask closure methods on linear dimensional changes of standardized simulated maxillary complete dentures.

Materials and methods: Thirty casts were made from a silicone mold representing an edentulous maxillary arch. Thirty identical maxillary dentures were made and randomly assigned to 3 test groups (A, B, C). In Group A, flasks were placed directly in pressure clamp after trial closure. Group B: The final closure was done in a hydraulic press then transferred to pressure clamp. Group C: After trial closure flask was positioned between the two iron plates of the Restriction System flask closure (RSFC) method. Then linear distances were measured three times before and after polymerization: right incisor to left incisor (RI-LI), right premolar to left premolar (RPM-LPM), right molar to left molar (RM-LM) and left incisor- to- left molar (LI-LM) and right incisor- to- right molar (RI-RM) with the help of digital caliper with an accuracy of 0.01mm. ANOVA and Tuckey's test were used to compare the groups (p < 0.05).

Results: Inter molar (LM-RM) width showed the greatest dimensional change after processing and Linear dimensions were not significantly influenced by the packing procedure.

Conclusion: Within the limitations of this study, Restriction System flask closure (RSFC) method demonstrated a similar performance in reducing the tooth movement when compared with other flask closure methods. The posterior region of the denture may present changes in the tooth position after processing, which need to be clinically adjusted.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Odontogenic myxoma of the maxilla: report of a case]. [Treatment management of a case of class I bialveolar protrusion with mouth breathing]. [Immediate full removable dentures. A clinical reality of oral medicine]. [Fortuitous discovery of a Stafne bone cavity in the Cone Beam CT sialography]. Ebola haemorrhagic fever and Nigerian dental healthcare providers - knowledge of the disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1