基于载体的封闭技术的体外评价:一项CBCT研究。

Annali di stomatologia Pub Date : 2016-07-19 eCollection Date: 2016-01-01 DOI:10.11138/ads/2016.7.1.011
Gianluca Gambarini, Lucila Piasecki, Giovanni Schianchi, Dario Di Nardo, Gabriele Miccoli, Dina Al Sudani, Roberto Di Giorgio, Luca Testarelli
{"title":"基于载体的封闭技术的体外评价:一项CBCT研究。","authors":"Gianluca Gambarini, Lucila Piasecki, Giovanni Schianchi, Dario Di Nardo, Gabriele Miccoli, Dina Al Sudani, Roberto Di Giorgio, Luca Testarelli","doi":"10.11138/ads/2016.7.1.011","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.</p><p><strong>Materials and methods: </strong>Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals.</p><p><strong>Results: </strong>There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05).</p><p><strong>Conclusions: </strong>The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil.</p>","PeriodicalId":78041,"journal":{"name":"Annali di stomatologia","volume":"7 1-2","pages":"11-5"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.11138/ads/2016.7.1.011","citationCount":"7","resultStr":"{\"title\":\"In vitro evaluation of carrier based obturation technique: a CBCT study.\",\"authors\":\"Gianluca Gambarini, Lucila Piasecki, Giovanni Schianchi, Dario Di Nardo, Gabriele Miccoli, Dina Al Sudani, Roberto Di Giorgio, Luca Testarelli\",\"doi\":\"10.11138/ads/2016.7.1.011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.</p><p><strong>Materials and methods: </strong>Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals.</p><p><strong>Results: </strong>There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05).</p><p><strong>Conclusions: </strong>The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil.</p>\",\"PeriodicalId\":78041,\"journal\":{\"name\":\"Annali di stomatologia\",\"volume\":\"7 1-2\",\"pages\":\"11-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.11138/ads/2016.7.1.011\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annali di stomatologia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11138/ads/2016.7.1.011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di stomatologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11138/ads/2016.7.1.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

目的:本研究的目的是通过CBCT比较两种不同的载体封闭(CBO)技术在三维根管系统中达到工作长度和填充的能力。材料与方法:对拔出的磨牙进行CBCT扫描,选取30°~ 90°的弯曲根管40根,分为两组(n=20)。使用镍钛器械将所有的根管准备至25锥度。06。SC组使用软核闭孔器(Kerr, Romulus, Mi, USA)进行闭孔,TH组(n= 20)使用Thermafil牙髓闭孔器(Tulsa Dental Products, Tulsa, OK, USA)进行闭孔,严格按照制造商的使用说明进行闭孔。通过CBCT对封闭情况进行分析,测量从根尖封闭极限到根尖孔的距离以及根管内是否存在空隙。结果:两组间封堵顶端距离均值比较,差异无统计学意义(t检验,p < 0.05)。仅3例出现过充(TH组2例,SC组1例)。两组空隙率均极低,差异无统计学意义(Z检验,p < 0.05)。结论:两种测试的CBO技术在性能方面显示出相似的积极结果,即使在与验证者核对后,在大多数情况下所选择的软核闭孔的尺寸比Thermafil小一个尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
In vitro evaluation of carrier based obturation technique: a CBCT study.

Aim: The goal of the study was to compare the ability of two different carrier based obturation (CBO) techniques to reach working length and fill in three-dimensions root canal systems, by using CBCT.

Materials and methods: Twenty-six extracted molars were scanned with CBCT and 40 curved canals were selected (between 30° and 90°) and divided in two similar groups (n=20). All canals were prepared up to size 25 taper .06 using nickel-titanium instrumentation. The canals in the Group SC were obturated using Soft-Core obturators (Kerr, Romulus, Mi, USA), while Group TH canals (n= 20) were obturated using Thermafil Endodontic Obturators (Tulsa Dental Products, Tulsa, OK, USA), strictly following manufacturers' instructions for use. The obturations were analyzed by means of CBCT to measure the distance from the apical limit of obturation to the apical foramen and the presence of voids inside root canals.

Results: There was no significant difference between the two groups in the mean distance of the apical extent of the obturation (t test, p>0.05). Overfilling occurred in only 3 cases (2 in Group TH and 1 in Group SC). The percentages of voids in both groups were very low with no significant difference (Z test, p>0.05).

Conclusions: The two tested CBO techniques showed similar positive results in terms of performance, even if, after checking with verifiers, in most cases the size of the selected Soft-Core obturator was one size smaller than Thermafil.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The use of botulinum toxin for medical-aesthetic purposes in dentistry: a comparative medico-legal approach in the context of the European Union Diagnostic reliability of the Digital Imaging Fiber Optic Transillumination: a review Modern concepts in Implant-Supported Fixed Complete Dental Prostheses (IFCDPs): from traditional solutions to current monolithic zirconia restorations. Concise review New procedures for the improvement of the SSN for a better access to dental care Squamos Odontogenic Tumor: A case report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1