在尼日利亚伊巴丹的临床参会者中,循环显微镜、定量巴菲大衣显微镜和快速诊断试剂盒用于疟疾诊断的成本效益和有效性评估。

Q2 Medicine Malaria Research and Treatment Pub Date : 2016-01-01 Epub Date: 2016-07-14 DOI:10.1155/2016/5242498
Abiodun Ogunniyi, Magbagbeola David Dairo, Hannah Dada-Adegbola, Ikeoluwapo O Ajayi, Adebola Olayinka, Wellington A Oyibo, Olufunmilayo I Fawole, Olufemi Ajumobi
{"title":"在尼日利亚伊巴丹的临床参会者中,循环显微镜、定量巴菲大衣显微镜和快速诊断试剂盒用于疟疾诊断的成本效益和有效性评估。","authors":"Abiodun Ogunniyi,&nbsp;Magbagbeola David Dairo,&nbsp;Hannah Dada-Adegbola,&nbsp;Ikeoluwapo O Ajayi,&nbsp;Adebola Olayinka,&nbsp;Wellington A Oyibo,&nbsp;Olufunmilayo I Fawole,&nbsp;Olufemi Ajumobi","doi":"10.1155/2016/5242498","DOIUrl":null,"url":null,"abstract":"<p><p>Background. Unavailability of accurate, rapid, reliable, and cost-effective malaria diagnostic instruments constitutes major a challenge to malaria elimination. We validated alternative malaria diagnostic instruments and assessed their comparative cost-effectiveness. Method. Using a cross-sectional study design, 502 patients with malaria symptoms at selected health facilities in Ibadan between January and April 2014 were recruited consecutively. We examined malaria parasites using Cyscope®, QBC, and CareStart™ and results were compared to light microscopy (LM). Validity was determined by assessing sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Costs per hour of use for instruments and turnaround time were determined. Result. Sensitivity of the instruments was 76.0% (CareStart), 95.0% (Cyscope), and 98.1% (QBC). Specificity was 96.0% (CareStart), 87.3% (Cyscope), and 85.5% (QBC). PPV were 65.2%, 67.5%, and 84.7%, while NPV were 93.6%, 98.6%, and 99.4% for CareStart, Cyscope, and QBC with Kappa values of 0.75 (CI = 0.68-0.82) for CareStart, 0.72 (CI = 0.65-0.78) for Cyscope, and 0.71 (CI = 0.64-0.77) for QBC. Average cost per hour of use was the lowest ($2.04) with the Cyscope. Turnaround time was the fastest with Cyscope (5 minutes). Conclusion. Cyscope fluorescent microscope had the shortest turnaround time and is the most cost-effective of all the malaria diagnostic instruments evaluated. </p>","PeriodicalId":18089,"journal":{"name":"Malaria Research and Treatment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2016/5242498","citationCount":"8","resultStr":"{\"title\":\"Cost-Effectiveness and Validity Assessment of Cyscope Microscope, Quantitative Buffy Coat Microscope, and Rapid Diagnostic Kit for Malaria Diagnosis among Clinic Attendees in Ibadan, Nigeria.\",\"authors\":\"Abiodun Ogunniyi,&nbsp;Magbagbeola David Dairo,&nbsp;Hannah Dada-Adegbola,&nbsp;Ikeoluwapo O Ajayi,&nbsp;Adebola Olayinka,&nbsp;Wellington A Oyibo,&nbsp;Olufunmilayo I Fawole,&nbsp;Olufemi Ajumobi\",\"doi\":\"10.1155/2016/5242498\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Background. Unavailability of accurate, rapid, reliable, and cost-effective malaria diagnostic instruments constitutes major a challenge to malaria elimination. We validated alternative malaria diagnostic instruments and assessed their comparative cost-effectiveness. Method. Using a cross-sectional study design, 502 patients with malaria symptoms at selected health facilities in Ibadan between January and April 2014 were recruited consecutively. We examined malaria parasites using Cyscope®, QBC, and CareStart™ and results were compared to light microscopy (LM). Validity was determined by assessing sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Costs per hour of use for instruments and turnaround time were determined. Result. Sensitivity of the instruments was 76.0% (CareStart), 95.0% (Cyscope), and 98.1% (QBC). Specificity was 96.0% (CareStart), 87.3% (Cyscope), and 85.5% (QBC). PPV were 65.2%, 67.5%, and 84.7%, while NPV were 93.6%, 98.6%, and 99.4% for CareStart, Cyscope, and QBC with Kappa values of 0.75 (CI = 0.68-0.82) for CareStart, 0.72 (CI = 0.65-0.78) for Cyscope, and 0.71 (CI = 0.64-0.77) for QBC. Average cost per hour of use was the lowest ($2.04) with the Cyscope. Turnaround time was the fastest with Cyscope (5 minutes). Conclusion. Cyscope fluorescent microscope had the shortest turnaround time and is the most cost-effective of all the malaria diagnostic instruments evaluated. </p>\",\"PeriodicalId\":18089,\"journal\":{\"name\":\"Malaria Research and Treatment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2016/5242498\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Malaria Research and Treatment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2016/5242498\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2016/7/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaria Research and Treatment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2016/5242498","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/7/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 8

摘要

背景。无法获得准确、快速、可靠和具有成本效益的疟疾诊断仪器对消除疟疾构成重大挑战。我们验证了其他疟疾诊断仪器,并评估了它们的相对成本效益。方法。采用横断面研究设计,2014年1月至4月期间在伊巴丹选定的卫生机构连续招募了502名出现疟疾症状的患者。我们使用Cyscope®、QBC和CareStart™检测疟疾寄生虫,并将结果与光学显微镜(LM)进行比较。效度通过评估敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)来确定。确定了仪器每小时的使用成本和周转时间。结果。仪器灵敏度分别为76.0% (CareStart)、95.0% (Cyscope)和98.1% (QBC)。特异性分别为96.0% (CareStart)、87.3% (Cyscope)和85.5% (QBC)。CareStart、Cyscope和QBC的PPV分别为65.2%、67.5%和84.7%,NPV分别为93.6%、98.6%和99.4%,其中CareStart的Kappa值为0.75 (CI = 0.68-0.82), Cyscope的Kappa值为0.72 (CI = 0.65-0.78), QBC的Kappa值为0.71 (CI = 0.64-0.77)。平均每小时使用成本是最低的($2.04)与Cyscope。周转时间最快的是Cyscope(5分钟)。结论。环形荧光显微镜的周转时间最短,是所有疟疾诊断仪器中性价比最高的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cost-Effectiveness and Validity Assessment of Cyscope Microscope, Quantitative Buffy Coat Microscope, and Rapid Diagnostic Kit for Malaria Diagnosis among Clinic Attendees in Ibadan, Nigeria.

Background. Unavailability of accurate, rapid, reliable, and cost-effective malaria diagnostic instruments constitutes major a challenge to malaria elimination. We validated alternative malaria diagnostic instruments and assessed their comparative cost-effectiveness. Method. Using a cross-sectional study design, 502 patients with malaria symptoms at selected health facilities in Ibadan between January and April 2014 were recruited consecutively. We examined malaria parasites using Cyscope®, QBC, and CareStart™ and results were compared to light microscopy (LM). Validity was determined by assessing sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Costs per hour of use for instruments and turnaround time were determined. Result. Sensitivity of the instruments was 76.0% (CareStart), 95.0% (Cyscope), and 98.1% (QBC). Specificity was 96.0% (CareStart), 87.3% (Cyscope), and 85.5% (QBC). PPV were 65.2%, 67.5%, and 84.7%, while NPV were 93.6%, 98.6%, and 99.4% for CareStart, Cyscope, and QBC with Kappa values of 0.75 (CI = 0.68-0.82) for CareStart, 0.72 (CI = 0.65-0.78) for Cyscope, and 0.71 (CI = 0.64-0.77) for QBC. Average cost per hour of use was the lowest ($2.04) with the Cyscope. Turnaround time was the fastest with Cyscope (5 minutes). Conclusion. Cyscope fluorescent microscope had the shortest turnaround time and is the most cost-effective of all the malaria diagnostic instruments evaluated.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Malaria Research and Treatment
Malaria Research and Treatment Medicine-Infectious Diseases
CiteScore
5.20
自引率
0.00%
发文量
0
期刊介绍: Malaria Research and Treatment is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to all aspects of malaria.
期刊最新文献
Expression of Concern on “Protective Effect of Quercetin on Chloroquine-Induced Oxidative Stress and Hepatotoxicity in Mice” Plasmodium falciparum and Plasmodium vivax Prevalence in Ethiopia: A Systematic Review and Meta-Analysis. The Incidence of Malaria Parasites in Screened Donor Blood for Transfusion. Oviposition and Development of Anopheles coluzzii coetzee and Wilkerson in Salt Water Prevalence and Factors Associated with Acute Kidney Injury among Malaria Patients in Dar es Salaam: A Cross-Sectional Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1