{"title":"心室辅助装置的传动系统感染及其在当前目的地治疗时代的意义。","authors":"Gabriel A Hernandez,&nbsp;Jonatan D Nunez Breton,&nbsp;Sandra V Chaparro","doi":"10.1177/1179065217714216","DOIUrl":null,"url":null,"abstract":"<p><p>Advances in mechanical circulatory support devices provided the technology to develop long-term, implantable left ventricular assist devices as bridge to transplant, destination therapy, and in a lesser group of patients, as bridge to recovery. Despite the benefits from this innovative therapy, with their increased use, many complications have been encountered, one of the most common being infections. With the driveline acting as a portal to the exterior environment, an infection involving this structure is the most frequent one. Because patients with destination therapy are expected to receive circulatory support for a longer period of time, we will focus this review on the risk factors, prevention, and treatment options for driveline infections.</p>","PeriodicalId":90668,"journal":{"name":"Open journal of cardiovascular surgery","volume":"9 ","pages":"1179065217714216"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1179065217714216","citationCount":"22","resultStr":"{\"title\":\"Driveline Infection in Ventricular Assist Devices and Its Implication in the Present Era of Destination Therapy.\",\"authors\":\"Gabriel A Hernandez,&nbsp;Jonatan D Nunez Breton,&nbsp;Sandra V Chaparro\",\"doi\":\"10.1177/1179065217714216\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Advances in mechanical circulatory support devices provided the technology to develop long-term, implantable left ventricular assist devices as bridge to transplant, destination therapy, and in a lesser group of patients, as bridge to recovery. Despite the benefits from this innovative therapy, with their increased use, many complications have been encountered, one of the most common being infections. With the driveline acting as a portal to the exterior environment, an infection involving this structure is the most frequent one. Because patients with destination therapy are expected to receive circulatory support for a longer period of time, we will focus this review on the risk factors, prevention, and treatment options for driveline infections.</p>\",\"PeriodicalId\":90668,\"journal\":{\"name\":\"Open journal of cardiovascular surgery\",\"volume\":\"9 \",\"pages\":\"1179065217714216\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1179065217714216\",\"citationCount\":\"22\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open journal of cardiovascular surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1179065217714216\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open journal of cardiovascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1179065217714216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

摘要

机械循环支持装置的进步为开发长期的、可植入的左心室辅助装置提供了技术,作为移植的桥梁,目的治疗,在少数患者中,作为恢复的桥梁。尽管这种创新疗法有好处,但随着使用的增加,也出现了许多并发症,其中最常见的是感染。由于传动系统是通往外部环境的门户,因此涉及该结构的感染是最常见的感染。由于接受目的地治疗的患者预计将接受更长时间的循环支持,因此我们将重点关注传动系统感染的危险因素、预防和治疗方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Driveline Infection in Ventricular Assist Devices and Its Implication in the Present Era of Destination Therapy.

Advances in mechanical circulatory support devices provided the technology to develop long-term, implantable left ventricular assist devices as bridge to transplant, destination therapy, and in a lesser group of patients, as bridge to recovery. Despite the benefits from this innovative therapy, with their increased use, many complications have been encountered, one of the most common being infections. With the driveline acting as a portal to the exterior environment, an infection involving this structure is the most frequent one. Because patients with destination therapy are expected to receive circulatory support for a longer period of time, we will focus this review on the risk factors, prevention, and treatment options for driveline infections.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Retrospective Analysis of Facial Fractures in Kuwait Head Injury as a Risk Factor for Inpatient Mortality Among Fall Patients in Malawi Can the Risk of the N Diseases Development be Related to the Degree of Differentiation of Tumor Cells and the Presence of Peritumoral Lymphocytic Infiltration in the Non Small Cell Lung Cancer Effectiveness of Efferent Loop Stimulation Prior to Protective Ileostomy Closure Short Profile of Children with Recurrent Inguinal Hernia in a Teaching Hospital in Enugu, Nigeria
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1