[犬肘肱尺骨不一致的计算机断层测量]。

IF 0.4 4区 医学 Q4 ORTHOPEDICS Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca Pub Date : 2017-01-01
R Snášil, P Proks, A Nečasová, K Michalčáková, A Nečas
{"title":"[犬肘肱尺骨不一致的计算机断层测量]。","authors":"R Snášil,&nbsp;P Proks,&nbsp;A Nečasová,&nbsp;K Michalčáková,&nbsp;A Nečas","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>PURPOSE OF THE STUDY The purpose of the study is to compare the repeatability and reproducibility of quantitative and subjective evaluation of elbow humeroulnar incongruity (HUI) using computed tomography (CT) on an in vivo canine model. MATERIAL AND METHODS HUI was evaluated on canine (n = 50) elbow joints (n = 100). The computed tomography of elbow joints was performed under intravenous sedation. Multiplanar reconstructions (MPR) were produced. HUI was evaluated on sagittal MPR images subjectively and by measuring the subluxation index (SI). The SI was defined by measuring the distance between the centres of two circles, the shape of which corresponded the most with the shape of the trochlear notch of the ulna at sagittal crest and the shape of humeral trochlea. This distance was divided by the radius of the circle (r) defining the humeral trochlea. HUI was subjectively evaluated based on the width of the joint space at the greatest caudal convexity of the trochlear notch of the ulna. Three categories of HUI were established: 0 (congruent), 1 (moderately incongruent), 2 (strongly incongruent). Measurement and evaluation of HUI was conducted by two evaluators twice at a one-month interval between the first and second measurement. The statistical analysis was carried out using the repeated measures ANOVA and the Cohen s kappa coefficient. RESULTS The mean SI was 11.14 (SD 8.703). The SI values measured by two evaluators were statistically significantly different (p < 0.05). Contrarily, there was no statistically significant difference between the two measurements of the same evaluator (p > 0.05). The subjective evaluation of HUI done by two evaluators showed a mean to substantial agreement (Kappa = 0.53-0.79). There was a substantial to almost perfect agreement between the results of two evaluations carried out by a single evaluator (Kappa = 0.79-0.83). DISCUSSION The radiographic detection of moderate incongruity is unreliable, especially on account of wrongly positioned elbow joint, superposition of bone structures and due to the evaluation of three-dimensional bone structure through a two-dimensional image. Evaluation of humeroulnar congruity by computed tomography (CT) enables to assess the congruity of joints without the superposition of neighbouring bone structures. The quantification of humeroulnar incongruity using the SI does not show a higher degree of agreement between two evaluators as against the subjective evaluation of HUI. On the contrary, the agreement between two measurements of a single evaluator was high in both the cases. CONCLUSIONS Dog is a suitable model animal for evaluation of HUI of elbow joints due to frequent incidence of elbow dysplasia associated with HUI. The quantification of HUI at the expense of subjective evaluation of HUI is often overrated in radiological studies. Key words: dog, elbow, humeroulnar incongruity.</p>","PeriodicalId":6980,"journal":{"name":"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca","volume":"84 4","pages":"299-303"},"PeriodicalIF":0.4000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Canine Elbow Humeroulnar Incongruity Measurements Using Computed Tomography].\",\"authors\":\"R Snášil,&nbsp;P Proks,&nbsp;A Nečasová,&nbsp;K Michalčáková,&nbsp;A Nečas\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>PURPOSE OF THE STUDY The purpose of the study is to compare the repeatability and reproducibility of quantitative and subjective evaluation of elbow humeroulnar incongruity (HUI) using computed tomography (CT) on an in vivo canine model. MATERIAL AND METHODS HUI was evaluated on canine (n = 50) elbow joints (n = 100). The computed tomography of elbow joints was performed under intravenous sedation. Multiplanar reconstructions (MPR) were produced. HUI was evaluated on sagittal MPR images subjectively and by measuring the subluxation index (SI). The SI was defined by measuring the distance between the centres of two circles, the shape of which corresponded the most with the shape of the trochlear notch of the ulna at sagittal crest and the shape of humeral trochlea. This distance was divided by the radius of the circle (r) defining the humeral trochlea. HUI was subjectively evaluated based on the width of the joint space at the greatest caudal convexity of the trochlear notch of the ulna. Three categories of HUI were established: 0 (congruent), 1 (moderately incongruent), 2 (strongly incongruent). Measurement and evaluation of HUI was conducted by two evaluators twice at a one-month interval between the first and second measurement. The statistical analysis was carried out using the repeated measures ANOVA and the Cohen s kappa coefficient. RESULTS The mean SI was 11.14 (SD 8.703). The SI values measured by two evaluators were statistically significantly different (p < 0.05). Contrarily, there was no statistically significant difference between the two measurements of the same evaluator (p > 0.05). The subjective evaluation of HUI done by two evaluators showed a mean to substantial agreement (Kappa = 0.53-0.79). There was a substantial to almost perfect agreement between the results of two evaluations carried out by a single evaluator (Kappa = 0.79-0.83). DISCUSSION The radiographic detection of moderate incongruity is unreliable, especially on account of wrongly positioned elbow joint, superposition of bone structures and due to the evaluation of three-dimensional bone structure through a two-dimensional image. Evaluation of humeroulnar congruity by computed tomography (CT) enables to assess the congruity of joints without the superposition of neighbouring bone structures. The quantification of humeroulnar incongruity using the SI does not show a higher degree of agreement between two evaluators as against the subjective evaluation of HUI. On the contrary, the agreement between two measurements of a single evaluator was high in both the cases. CONCLUSIONS Dog is a suitable model animal for evaluation of HUI of elbow joints due to frequent incidence of elbow dysplasia associated with HUI. The quantification of HUI at the expense of subjective evaluation of HUI is often overrated in radiological studies. Key words: dog, elbow, humeroulnar incongruity.</p>\",\"PeriodicalId\":6980,\"journal\":{\"name\":\"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca\",\"volume\":\"84 4\",\"pages\":\"299-303\"},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是比较用计算机断层扫描(CT)在犬体内模型上对肘关节肱骨尺骨不一致(HUI)进行定量和主观评估的可重复性和再现性。材料与方法对犬(n = 50)肘关节(n = 100)进行HUI评价。在静脉镇静下进行肘关节计算机断层扫描。生成了多平面重建(MPR)。HUI主观评价矢状面MPR图像和测量半脱位指数(SI)。通过测量两个圆中心之间的距离来定义SI,其形状与尺骨矢状嵴滑车切迹的形状和肱骨滑车的形状最吻合。这个距离除以肱骨滑车的半径r。根据尺骨滑车陷迹尾端最大凸度处关节间隙的宽度主观评价HUI。建立了3个类别的HUI: 0(一致),1(中度不一致),2(强烈不一致)。HUI的测量和评估由两名评估人员在第一次和第二次测量之间的一个月间隔进行两次。统计分析采用重复测量方差分析和科恩卡帕系数。结果平均SI为11.14 (SD为8.703)。两种评估者测量的SI值差异有统计学意义(p < 0.05)。相反,同一评估者的两项测量结果差异无统计学意义(p > 0.05)。两位评价者对HUI的主观评价显示,平均到基本一致(Kappa = 0.53-0.79)。由单个评估者进行的两次评估结果之间存在实质性的几乎完美的一致性(Kappa = 0.79-0.83)。中度不一致的x线检查是不可靠的,特别是由于肘关节位置错误,骨结构重叠以及通过二维图像评估三维骨结构。通过计算机断层扫描(CT)评估肱骨尺整合度可以评估关节的整合度,而不会重叠邻近的骨结构。与HUI的主观评价相比,SI对肱骨尺骨不协调的量化并没有显示出两个评估者之间更高程度的一致性。相反,在这两种情况下,同一评价者的两次测量结果之间的一致性都很高。结论犬肘关节发育不良常与肘关节HUI相关,是评估肘关节HUI的合适模型动物。在放射学研究中,以主观评价为代价的HUI量化常常被高估。关键词:狗,肘部,肱尺骨不协调。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Canine Elbow Humeroulnar Incongruity Measurements Using Computed Tomography].

PURPOSE OF THE STUDY The purpose of the study is to compare the repeatability and reproducibility of quantitative and subjective evaluation of elbow humeroulnar incongruity (HUI) using computed tomography (CT) on an in vivo canine model. MATERIAL AND METHODS HUI was evaluated on canine (n = 50) elbow joints (n = 100). The computed tomography of elbow joints was performed under intravenous sedation. Multiplanar reconstructions (MPR) were produced. HUI was evaluated on sagittal MPR images subjectively and by measuring the subluxation index (SI). The SI was defined by measuring the distance between the centres of two circles, the shape of which corresponded the most with the shape of the trochlear notch of the ulna at sagittal crest and the shape of humeral trochlea. This distance was divided by the radius of the circle (r) defining the humeral trochlea. HUI was subjectively evaluated based on the width of the joint space at the greatest caudal convexity of the trochlear notch of the ulna. Three categories of HUI were established: 0 (congruent), 1 (moderately incongruent), 2 (strongly incongruent). Measurement and evaluation of HUI was conducted by two evaluators twice at a one-month interval between the first and second measurement. The statistical analysis was carried out using the repeated measures ANOVA and the Cohen s kappa coefficient. RESULTS The mean SI was 11.14 (SD 8.703). The SI values measured by two evaluators were statistically significantly different (p < 0.05). Contrarily, there was no statistically significant difference between the two measurements of the same evaluator (p > 0.05). The subjective evaluation of HUI done by two evaluators showed a mean to substantial agreement (Kappa = 0.53-0.79). There was a substantial to almost perfect agreement between the results of two evaluations carried out by a single evaluator (Kappa = 0.79-0.83). DISCUSSION The radiographic detection of moderate incongruity is unreliable, especially on account of wrongly positioned elbow joint, superposition of bone structures and due to the evaluation of three-dimensional bone structure through a two-dimensional image. Evaluation of humeroulnar congruity by computed tomography (CT) enables to assess the congruity of joints without the superposition of neighbouring bone structures. The quantification of humeroulnar incongruity using the SI does not show a higher degree of agreement between two evaluators as against the subjective evaluation of HUI. On the contrary, the agreement between two measurements of a single evaluator was high in both the cases. CONCLUSIONS Dog is a suitable model animal for evaluation of HUI of elbow joints due to frequent incidence of elbow dysplasia associated with HUI. The quantification of HUI at the expense of subjective evaluation of HUI is often overrated in radiological studies. Key words: dog, elbow, humeroulnar incongruity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
25.00%
发文量
53
期刊介绍: Editorial Board accepts for publication articles, reports from congresses, fellowships, book reviews, reports concerning activities of orthopaedic and other relating specialised societies, reports on anniversaries of outstanding personalities in orthopaedics and announcements of congresses and symposia being prepared. Articles include original papers, case reports and current concepts reviews and recently also instructional lectures.
期刊最新文献
[Arthroscopic Subtalar Distraction Arthrodesis in Post-Traumatic Indications]. [Sagittal Profi le of the Spine in Patients after Lumbar Stabilisation Surgeries]. [Total Hip Arthroplasty Using the AMIS Method: Surgical Technique, Suitability of This Method for Obese Patients, Evaluation of the Study Population]. Management of Length Unstable Femur Fractures in Children by Flexible Intramedullary Nails: A Systematic Review. Reconstruction after Pelvic Bone Massive Resection: Evolution and Actuality of 3D-Printing Technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1