不同市售正畸微型种植体离子释放的比较评估-一项体外研究。

Q Medicine Australian Orthodontic Journal Pub Date : 2016-11-01
Venkateswaran Ananthanarayanan, Sridevi Padmanabhan, Arun B Chitharanjan
{"title":"不同市售正畸微型种植体离子释放的比较评估-一项体外研究。","authors":"Venkateswaran Ananthanarayanan,&nbsp;Sridevi Padmanabhan,&nbsp;Arun B Chitharanjan","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Titanium alloy mini-implants have become popular in recent times and have been extensively used and studied. Although corrosion resistance of orthodontic materials has always been of concern, this property has been the least explored. The present study aimed to assess the composition, surface characterisation and corrosion resistance of five commercially available mini-implants by assaying ion release in artificial saliva.</p><p><strong>Methods: </strong>Ten mini-implants each from five companies were obtained: Group 1 - AbsoAnchor (Dentos Inc, South Korea); Group 2 - Microimplant Anchorage System (MIA, Biomaterials Korea); Group 3 - The Orthodontic Mini Anchorage System (TOMAS, Dentaurum, Germany); Group 4 - mini-implants (Denticon, Maharashtra, India); Group 5 - orthodontic mini-implants (lJ.Orthodontics, Kerala, India). One mini-implant from each group was subjected to characterisation and surface microstructure analysis using Energy Dispersive Atomic Spectrometry (EDAX) and Scanning Electron Microscope (SEM), respectively. Ten mini- implants were immersed for 30 days in Fusayama-Meyer artificial saliva solution and the release of titanium, aluminium and vanadium ions was detected with Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES). The Kruskal-Wallis test was used for multi-variate analysis. In order to determine the significant differences between the groups on independent samples, the Mann-Whitney U test (bi-variate analysis) was applied.</p><p><strong>Results and conclusion: </strong>All groups showed machining defects but surface pitting after immersion was mostly evident in Group 4. Although the composition of all the implants was comparable, there was a statistically significant difference in the Ti, Al and V release between Group 4 - the group with maximum release - and Group 2, the group with least release.</p>","PeriodicalId":55417,"journal":{"name":"Australian Orthodontic Journal","volume":"32 2","pages":"165-174"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparative evaluation of ion release from different commercially-available orthodontic mini-implants - an in-vitro study.\",\"authors\":\"Venkateswaran Ananthanarayanan,&nbsp;Sridevi Padmanabhan,&nbsp;Arun B Chitharanjan\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Titanium alloy mini-implants have become popular in recent times and have been extensively used and studied. Although corrosion resistance of orthodontic materials has always been of concern, this property has been the least explored. The present study aimed to assess the composition, surface characterisation and corrosion resistance of five commercially available mini-implants by assaying ion release in artificial saliva.</p><p><strong>Methods: </strong>Ten mini-implants each from five companies were obtained: Group 1 - AbsoAnchor (Dentos Inc, South Korea); Group 2 - Microimplant Anchorage System (MIA, Biomaterials Korea); Group 3 - The Orthodontic Mini Anchorage System (TOMAS, Dentaurum, Germany); Group 4 - mini-implants (Denticon, Maharashtra, India); Group 5 - orthodontic mini-implants (lJ.Orthodontics, Kerala, India). One mini-implant from each group was subjected to characterisation and surface microstructure analysis using Energy Dispersive Atomic Spectrometry (EDAX) and Scanning Electron Microscope (SEM), respectively. Ten mini- implants were immersed for 30 days in Fusayama-Meyer artificial saliva solution and the release of titanium, aluminium and vanadium ions was detected with Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES). The Kruskal-Wallis test was used for multi-variate analysis. In order to determine the significant differences between the groups on independent samples, the Mann-Whitney U test (bi-variate analysis) was applied.</p><p><strong>Results and conclusion: </strong>All groups showed machining defects but surface pitting after immersion was mostly evident in Group 4. Although the composition of all the implants was comparable, there was a statistically significant difference in the Ti, Al and V release between Group 4 - the group with maximum release - and Group 2, the group with least release.</p>\",\"PeriodicalId\":55417,\"journal\":{\"name\":\"Australian Orthodontic Journal\",\"volume\":\"32 2\",\"pages\":\"165-174\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australian Orthodontic Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australian Orthodontic Journal","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:钛合金微型种植体近年来得到广泛应用和研究。虽然正畸材料的耐腐蚀性能一直是人们关注的问题,但这方面的研究却很少。本研究旨在通过分析人工唾液中的离子释放来评估五种市售微型植入物的组成、表面特征和耐腐蚀性。方法:从5家公司各获得10个微型种植体:第一组- AbsoAnchor (Dentos Inc .,韩国);第二组:Microimplant anchor System (MIA, Biomaterials Korea);第三组:正畸迷你支抗系统(TOMAS, Dentaurum,德国);第4组-微型种植体(Denticon, Maharashtra,印度);第五组-正畸微型种植体。正畸,喀拉拉邦,印度)。采用能量色散原子光谱法(EDAX)和扫描电镜(SEM)对每组各1个微型种植体进行表征和表面微观结构分析。10个微型种植体在Fusayama-Meyer人工唾液溶液中浸泡30 d,用电感耦合等离子体-光学发射光谱法(ICP-OES)检测钛、铝和钒离子的释放。采用Kruskal-Wallis检验进行多因素分析。为了确定独立样本组间的显著差异,采用Mann-Whitney U检验(双变量分析)。结果与结论:各组均存在加工缺陷,但第4组浸泡后表面麻点多见。虽然所有植入物的组成具有可比性,但在释放量最大的第4组和释放量最少的第2组之间,Ti、Al和V的释放量有统计学意义的差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A comparative evaluation of ion release from different commercially-available orthodontic mini-implants - an in-vitro study.

Background: Titanium alloy mini-implants have become popular in recent times and have been extensively used and studied. Although corrosion resistance of orthodontic materials has always been of concern, this property has been the least explored. The present study aimed to assess the composition, surface characterisation and corrosion resistance of five commercially available mini-implants by assaying ion release in artificial saliva.

Methods: Ten mini-implants each from five companies were obtained: Group 1 - AbsoAnchor (Dentos Inc, South Korea); Group 2 - Microimplant Anchorage System (MIA, Biomaterials Korea); Group 3 - The Orthodontic Mini Anchorage System (TOMAS, Dentaurum, Germany); Group 4 - mini-implants (Denticon, Maharashtra, India); Group 5 - orthodontic mini-implants (lJ.Orthodontics, Kerala, India). One mini-implant from each group was subjected to characterisation and surface microstructure analysis using Energy Dispersive Atomic Spectrometry (EDAX) and Scanning Electron Microscope (SEM), respectively. Ten mini- implants were immersed for 30 days in Fusayama-Meyer artificial saliva solution and the release of titanium, aluminium and vanadium ions was detected with Inductively Coupled Plasma - Optical Emission Spectrometry (ICP-OES). The Kruskal-Wallis test was used for multi-variate analysis. In order to determine the significant differences between the groups on independent samples, the Mann-Whitney U test (bi-variate analysis) was applied.

Results and conclusion: All groups showed machining defects but surface pitting after immersion was mostly evident in Group 4. Although the composition of all the implants was comparable, there was a statistically significant difference in the Ti, Al and V release between Group 4 - the group with maximum release - and Group 2, the group with least release.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Australian Orthodontic Journal
Australian Orthodontic Journal DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.48
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Minimizing publication bias. Looking backwards into the Future of Orthodontics. Orthodontic Education. Australian Orthodontists: are they "with it". The role of the foundation in Australian Orthodontic education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1