{"title":"PIVO装置对外周静脉导管采血的影响。","authors":"Suzanne Adams,&nbsp;Bridget Toroni,&nbsp;Meenal Lele","doi":"10.1155/2018/7380527","DOIUrl":null,"url":null,"abstract":"<p><p>Short peripheral catheters (SPC) are an existing conduit into many patients' veins and line draws from SPC are a desired method of routine blood collection especially in difficult venous access patients. The PIVO device facilitates blood collection through SPC and is being used clinically in a number of hospitals. This study aimed to determine the appropriate wait time following a flush and the minimum waste volume required to obtain an undiluted blood sample when using the PIVO device and how that differed from current guidelines from SPC line draws. A clinical study was conducted examining the analyte results of samples drawn with PIVO through a SPC at varying wait times following a saline flush. Both an initial waste volume and a postwaste sample were compared to a venipuncture control. The resulting samples showed no saline dilution as measured by sodium and creatinine results at all studied wait times. These findings suggest that blood collections using the PIVO device can produce a clinically valid sample with a 30-second wait following a SPC flush and no waste volume prior to sample collection.</p>","PeriodicalId":46917,"journal":{"name":"Nursing Research and Practice","volume":"2018 ","pages":"7380527"},"PeriodicalIF":2.2000,"publicationDate":"2018-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2018/7380527","citationCount":"4","resultStr":"{\"title\":\"Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters.\",\"authors\":\"Suzanne Adams,&nbsp;Bridget Toroni,&nbsp;Meenal Lele\",\"doi\":\"10.1155/2018/7380527\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Short peripheral catheters (SPC) are an existing conduit into many patients' veins and line draws from SPC are a desired method of routine blood collection especially in difficult venous access patients. The PIVO device facilitates blood collection through SPC and is being used clinically in a number of hospitals. This study aimed to determine the appropriate wait time following a flush and the minimum waste volume required to obtain an undiluted blood sample when using the PIVO device and how that differed from current guidelines from SPC line draws. A clinical study was conducted examining the analyte results of samples drawn with PIVO through a SPC at varying wait times following a saline flush. Both an initial waste volume and a postwaste sample were compared to a venipuncture control. The resulting samples showed no saline dilution as measured by sodium and creatinine results at all studied wait times. These findings suggest that blood collections using the PIVO device can produce a clinically valid sample with a 30-second wait following a SPC flush and no waste volume prior to sample collection.</p>\",\"PeriodicalId\":46917,\"journal\":{\"name\":\"Nursing Research and Practice\",\"volume\":\"2018 \",\"pages\":\"7380527\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2018-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2018/7380527\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nursing Research and Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2018/7380527\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"NURSING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nursing Research and Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2018/7380527","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 4

摘要

短外周导管(SPC)是许多患者静脉的现有导管,从SPC提取血液是常规血液采集的理想方法,特别是在静脉通道困难的患者中。PIVO设备通过SPC促进血液采集,并在一些医院临床使用。本研究旨在确定冲洗后的适当等待时间和使用PIVO设备时获得未稀释血液样本所需的最小浪费量,以及与目前SPC划线指南的不同之处。进行了一项临床研究,检查了通过SPC在生理盐水冲洗后不同等待时间用PIVO抽取的样品的分析结果。将初始废物量和废物后样本与静脉穿刺对照进行比较。结果显示,在所有研究的等待时间内,钠和肌酐的测量结果没有盐水稀释。这些发现表明,使用PIVO设备采集血液可以产生临床有效的样本,在SPC冲洗后等待30秒,并且在采集样本之前没有浪费。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters.

Short peripheral catheters (SPC) are an existing conduit into many patients' veins and line draws from SPC are a desired method of routine blood collection especially in difficult venous access patients. The PIVO device facilitates blood collection through SPC and is being used clinically in a number of hospitals. This study aimed to determine the appropriate wait time following a flush and the minimum waste volume required to obtain an undiluted blood sample when using the PIVO device and how that differed from current guidelines from SPC line draws. A clinical study was conducted examining the analyte results of samples drawn with PIVO through a SPC at varying wait times following a saline flush. Both an initial waste volume and a postwaste sample were compared to a venipuncture control. The resulting samples showed no saline dilution as measured by sodium and creatinine results at all studied wait times. These findings suggest that blood collections using the PIVO device can produce a clinically valid sample with a 30-second wait following a SPC flush and no waste volume prior to sample collection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.90
自引率
0.00%
发文量
21
审稿时长
19 weeks
期刊最新文献
Nursing Faculty Shortage Impact on Nursing Students: A Descriptive Phenomenological Study. Nurses' Perception on the Hindrances of Triage System in Emergency Unit. Development of a Symptom Self-Management Guide for Older Chinese Americans Kidney Receiving Replacement Therapy. NoFumo+: Mobile Health App to Quit Smoking Using Cognitive-Behavioral Therapy. Measuring Cardiovascular Disease Risk Perception: Translation and Validation of the Indonesian ABCD Risk Questionnaire.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1