与钛植入物有关的异物反应,边缘骨质流失和过敏。

Q1 Dentistry European Journal of Oral Implantology Pub Date : 2018-01-01
Tomas Albrektsson, Bruno Chrcanovic, Johan Mölne, Ann Wennerberg
{"title":"与钛植入物有关的异物反应,边缘骨质流失和过敏。","authors":"Tomas Albrektsson,&nbsp;Bruno Chrcanovic,&nbsp;Johan Mölne,&nbsp;Ann Wennerberg","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To describe general observations of immunological reactions to foreign materials and to realize that CP titanium gives rise to a foreign body reaction with subsequent bone embedment when placed as oral implants. To analyse the possibility of titanium allergy.</p><p><strong>Materials and methods: </strong>The present paper is of a narrative review type. Hand and Medline searches were performed to evaluate marginal bone loss of oral implants and the potential of titanium allergy.</p><p><strong>Results: </strong>Immunological reactions to foreign substances include Type I hypersensitivity reactions such as allergy, Type II hypersensitivity reactions characterised by IgM or IgG antibodies that may react with blood group antigens at transfusion, and Type III hypersensitivity caused by antigen-antibody immune complexes exemplified by acute serum sickness. There is also Type IV hypersensitivity, or delayed hypersensitivity, which is typically found in drug and foreign body reactions. It proved very difficult to find a universally acceptable definition of reasons for marginal bone loss around oral implants, which lead to most varying figures of so-called peri-implantitis being 1% to 2% in some 10-year follow-up papers to between 28% and 56% of all placed implants in other papers. It was recognised that bone resorption to oral as well as orthopaedic implants may be due to immunological reactions. Today, osseointegration is seen as an immune-modulated inflammatory process where the immune system is locally either up- or downregulated. Titanium implant allergy is a rare condition, if it exists. The authors found only two papers presenting strong evidence of allergy to CP titanium, but with the lack of universally accepted and tested patch tests, the precise diagnosis is difficult.</p><p><strong>Conclusions: </strong>CP titanium acts as a foreign body when placed in live tissues. There may be immunological reasons behind marginal bone loss. Titanium allergy may exist in rare cases, but there is a lack of properly designed and analysed patch tests at present.</p>","PeriodicalId":49259,"journal":{"name":"European Journal of Oral Implantology","volume":"11 Suppl 1 ","pages":"S37-S46"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Foreign body reactions, marginal bone loss and allergies in relation to titanium implants.\",\"authors\":\"Tomas Albrektsson,&nbsp;Bruno Chrcanovic,&nbsp;Johan Mölne,&nbsp;Ann Wennerberg\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>To describe general observations of immunological reactions to foreign materials and to realize that CP titanium gives rise to a foreign body reaction with subsequent bone embedment when placed as oral implants. To analyse the possibility of titanium allergy.</p><p><strong>Materials and methods: </strong>The present paper is of a narrative review type. Hand and Medline searches were performed to evaluate marginal bone loss of oral implants and the potential of titanium allergy.</p><p><strong>Results: </strong>Immunological reactions to foreign substances include Type I hypersensitivity reactions such as allergy, Type II hypersensitivity reactions characterised by IgM or IgG antibodies that may react with blood group antigens at transfusion, and Type III hypersensitivity caused by antigen-antibody immune complexes exemplified by acute serum sickness. There is also Type IV hypersensitivity, or delayed hypersensitivity, which is typically found in drug and foreign body reactions. It proved very difficult to find a universally acceptable definition of reasons for marginal bone loss around oral implants, which lead to most varying figures of so-called peri-implantitis being 1% to 2% in some 10-year follow-up papers to between 28% and 56% of all placed implants in other papers. It was recognised that bone resorption to oral as well as orthopaedic implants may be due to immunological reactions. Today, osseointegration is seen as an immune-modulated inflammatory process where the immune system is locally either up- or downregulated. Titanium implant allergy is a rare condition, if it exists. The authors found only two papers presenting strong evidence of allergy to CP titanium, but with the lack of universally accepted and tested patch tests, the precise diagnosis is difficult.</p><p><strong>Conclusions: </strong>CP titanium acts as a foreign body when placed in live tissues. There may be immunological reasons behind marginal bone loss. Titanium allergy may exist in rare cases, but there is a lack of properly designed and analysed patch tests at present.</p>\",\"PeriodicalId\":49259,\"journal\":{\"name\":\"European Journal of Oral Implantology\",\"volume\":\"11 Suppl 1 \",\"pages\":\"S37-S46\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Oral Implantology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Implantology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:描述对外来物质的免疫反应的一般观察结果,并认识到CP钛作为口腔种植体放置时会引起异物反应并随后进行骨植入。分析钛过敏的可能性。材料与方法:本文为叙述性综述型。通过手工和Medline搜索来评估口腔种植体的边缘骨丢失和钛过敏的可能性。结果:对外来物质的免疫反应包括I型超敏反应,如过敏;II型超敏反应以IgM或IgG抗体为特征,在输血时可能与血型抗原发生反应;III型超敏反应由抗原-抗体免疫复合物引起,如急性血清病。还有IV型超敏反应,或延迟性超敏反应,通常见于药物和异物反应。事实证明,很难找到一个普遍接受的口腔种植体周围边缘骨质流失原因的定义,这导致所谓的种植体周围炎在一些10年随访论文中占1%至2%,而在其他论文中占所有种植体的28%至56%。人们认识到,口腔和骨科植入物的骨吸收可能是由于免疫反应。如今,骨整合被视为一种免疫调节的炎症过程,其中免疫系统局部上调或下调。钛植入物过敏是一种罕见的情况,如果存在的话。作者发现只有两篇论文提出了对CP钛过敏的有力证据,但由于缺乏普遍接受和经过测试的斑贴试验,精确的诊断是困难的。结论:CP钛在活体组织中起异物作用。边缘骨质流失背后可能有免疫方面的原因。钛过敏可能在极少数情况下存在,但目前缺乏适当设计和分析的贴片试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Foreign body reactions, marginal bone loss and allergies in relation to titanium implants.

Aim: To describe general observations of immunological reactions to foreign materials and to realize that CP titanium gives rise to a foreign body reaction with subsequent bone embedment when placed as oral implants. To analyse the possibility of titanium allergy.

Materials and methods: The present paper is of a narrative review type. Hand and Medline searches were performed to evaluate marginal bone loss of oral implants and the potential of titanium allergy.

Results: Immunological reactions to foreign substances include Type I hypersensitivity reactions such as allergy, Type II hypersensitivity reactions characterised by IgM or IgG antibodies that may react with blood group antigens at transfusion, and Type III hypersensitivity caused by antigen-antibody immune complexes exemplified by acute serum sickness. There is also Type IV hypersensitivity, or delayed hypersensitivity, which is typically found in drug and foreign body reactions. It proved very difficult to find a universally acceptable definition of reasons for marginal bone loss around oral implants, which lead to most varying figures of so-called peri-implantitis being 1% to 2% in some 10-year follow-up papers to between 28% and 56% of all placed implants in other papers. It was recognised that bone resorption to oral as well as orthopaedic implants may be due to immunological reactions. Today, osseointegration is seen as an immune-modulated inflammatory process where the immune system is locally either up- or downregulated. Titanium implant allergy is a rare condition, if it exists. The authors found only two papers presenting strong evidence of allergy to CP titanium, but with the lack of universally accepted and tested patch tests, the precise diagnosis is difficult.

Conclusions: CP titanium acts as a foreign body when placed in live tissues. There may be immunological reasons behind marginal bone loss. Titanium allergy may exist in rare cases, but there is a lack of properly designed and analysed patch tests at present.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Oral Implantology
European Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.35
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Immediate loading of fixed prostheses in fully edentulous jaws - 1-year follow-up from a single-cohort retrospective study. Research in focus. Dental implants with internal versus external connections: 1-year post-loading results from a pragmatic multicenter randomised controlled trial. Research in focus. Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1