[乳腺成像的发展]。

Nihon Geka Gakkai zasshi Pub Date : 2016-11-01
Sadako Akashi-Tanaka
{"title":"[乳腺成像的发展]。","authors":"Sadako Akashi-Tanaka","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Breast cancer is the most frequent cancer in Japanese women. As breast density increases, the detection rate of breast cancer by mammography (MMG) decreases. Breast density notification laws have been enacted in several states in the USA. Supplemental screening tools for women with dense breasts are needed. The results of a large randomized trial to compare the sensitivity, specificity, and cancer detection rate of MMG and adjunctive ultrasonography (US) to screen for breast cancer in Japan (J-START) were reported last year. More than 70,000 women aged 40 to 49 years were enrolled. The sensitivity and cancer detection rate were significantly higher in the MMG+US group than in the MMG-alone group. Automated breast ultrasonography is a tool to overcome the operator dependency of hand-held US and low reproducibility. Digital breast tomosynthesis, referred to as 3D MMG, offers higher sensitivity and specificity than MMG. Contrast-enhanced spectral MMG is an MMG scan using contrast medium to detect breast cancer more clearly even in dense breasts. It is often used for women at high risk for cancer and substituted for magnetic resonance imaging. A dedicated breast positron-emission tomography (PET) system has been available in Japan with insurance coverage since 2013. More cases of cancer were detected using breast PET than whole-body PET. Additional studies including mortality rates are needed.</p>","PeriodicalId":19165,"journal":{"name":"Nihon Geka Gakkai zasshi","volume":"117 6","pages":"483-90"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[DEVELOPMENTS IN BREAST IMAGING].\",\"authors\":\"Sadako Akashi-Tanaka\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Breast cancer is the most frequent cancer in Japanese women. As breast density increases, the detection rate of breast cancer by mammography (MMG) decreases. Breast density notification laws have been enacted in several states in the USA. Supplemental screening tools for women with dense breasts are needed. The results of a large randomized trial to compare the sensitivity, specificity, and cancer detection rate of MMG and adjunctive ultrasonography (US) to screen for breast cancer in Japan (J-START) were reported last year. More than 70,000 women aged 40 to 49 years were enrolled. The sensitivity and cancer detection rate were significantly higher in the MMG+US group than in the MMG-alone group. Automated breast ultrasonography is a tool to overcome the operator dependency of hand-held US and low reproducibility. Digital breast tomosynthesis, referred to as 3D MMG, offers higher sensitivity and specificity than MMG. Contrast-enhanced spectral MMG is an MMG scan using contrast medium to detect breast cancer more clearly even in dense breasts. It is often used for women at high risk for cancer and substituted for magnetic resonance imaging. A dedicated breast positron-emission tomography (PET) system has been available in Japan with insurance coverage since 2013. More cases of cancer were detected using breast PET than whole-body PET. Additional studies including mortality rates are needed.</p>\",\"PeriodicalId\":19165,\"journal\":{\"name\":\"Nihon Geka Gakkai zasshi\",\"volume\":\"117 6\",\"pages\":\"483-90\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nihon Geka Gakkai zasshi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nihon Geka Gakkai zasshi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

乳腺癌是日本女性中最常见的癌症。随着乳腺密度的增加,乳房x光检查(MMG)的乳腺癌检出率降低。美国的几个州已经颁布了乳腺密度通报法。乳腺致密的妇女需要补充筛查工具。去年在日本进行了一项大型随机试验,比较MMG和辅助超声检查(US)筛查乳腺癌的敏感性、特异性和癌症检出率(J-START)。超过7万名年龄在40至49岁之间的女性参与了这项研究。MMG+US组的敏感性和肿瘤检出率均明显高于单独MMG组。自动乳房超声检查是一种克服操作人员对手持超声的依赖和低再现性的工具。数字乳房断层合成,即3D MMG,比MMG具有更高的灵敏度和特异性。对比增强光谱MMG是一种使用造影剂的MMG扫描,即使在致密的乳房中也能更清楚地发现乳腺癌。它通常用于癌症高风险的女性,并取代磁共振成像。自2013年以来,一种专用的乳房正电子发射断层扫描(PET)系统已在日本提供保险。乳房PET比全身PET检出更多的癌症病例。需要进行包括死亡率在内的进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[DEVELOPMENTS IN BREAST IMAGING].

Breast cancer is the most frequent cancer in Japanese women. As breast density increases, the detection rate of breast cancer by mammography (MMG) decreases. Breast density notification laws have been enacted in several states in the USA. Supplemental screening tools for women with dense breasts are needed. The results of a large randomized trial to compare the sensitivity, specificity, and cancer detection rate of MMG and adjunctive ultrasonography (US) to screen for breast cancer in Japan (J-START) were reported last year. More than 70,000 women aged 40 to 49 years were enrolled. The sensitivity and cancer detection rate were significantly higher in the MMG+US group than in the MMG-alone group. Automated breast ultrasonography is a tool to overcome the operator dependency of hand-held US and low reproducibility. Digital breast tomosynthesis, referred to as 3D MMG, offers higher sensitivity and specificity than MMG. Contrast-enhanced spectral MMG is an MMG scan using contrast medium to detect breast cancer more clearly even in dense breasts. It is often used for women at high risk for cancer and substituted for magnetic resonance imaging. A dedicated breast positron-emission tomography (PET) system has been available in Japan with insurance coverage since 2013. More cases of cancer were detected using breast PET than whole-body PET. Additional studies including mortality rates are needed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[NEXT STAGE OF NATIONAL CLINICAL DATABASE]. [RELATIONSHIP BETWEEN SURGICAL PROCEDURES AND THEIR SURGEON’S FEE]. [PERIOPERATIVE ORAL MANAGEMENT FOR ESOPHAGEAL CANCER AND LUNG CANCER SURGERY]. [BASIC RESEARCH BY SURGEONS]. [WHAT IS MENTAL PREPARATION OF LEADER TO ACHIEVE GENDER EQUALITY OF IDEAL]?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1