自动超声系统在滑膜炎诊断中的价值。

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Ultrasound International Open Pub Date : 2018-04-01 Epub Date: 2018-07-11 DOI:10.1055/a-0612-7852
Ruediger Mueller, Mathias Grunke, Jörg Wendler, Florian Schuch, Karina Hofmann-Preiss, Ina Boettger, Rüdiger Jakobs, Hendrik Schulze-Koops, Johannes von Kempis
{"title":"自动超声系统在滑膜炎诊断中的价值。","authors":"Ruediger Mueller,&nbsp;Mathias Grunke,&nbsp;Jörg Wendler,&nbsp;Florian Schuch,&nbsp;Karina Hofmann-Preiss,&nbsp;Ina Boettger,&nbsp;Rüdiger Jakobs,&nbsp;Hendrik Schulze-Koops,&nbsp;Johannes von Kempis","doi":"10.1055/a-0612-7852","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The detection of joint swelling caused by synovitis is important for the diagnosis of inflammatory arthritis. Ultrasound (US) and MRI have proven to be more sensitive and reliable than physical examination, but they are time-consuming and expensive. The automated breast volume scanner was developed to acquire serial B-mode pictures of the female breast and these can be analyzed in all three dimensions.</p><p><strong>Objectives: </strong>To analyze the value of automated B-mode ultrasound employing the ABVS system in detecting synovitis of the finger joints compared to manual ultrasound (mUS) and physical examination, using MRI as the gold standard.</p><p><strong>Methods: </strong>19 consecutive patients suffering from active rheumatoid (n=15) or psoriatic (n=4) arthritis were included. Automated and mUS were conducted with a linear array (ACUSON S2000™, 11 MHz). Multiplanar reconstruction enabled examination of the images for the presence of synovitis.</p><p><strong>Results: </strong>90% of the hand joints were assessable by automated ultrasound. Automated US detected 12.0, mUS 14.2, MRI 13.4, and clinical examination 4.1 positive joints - i. e. joints with synovitis - on average per patient. The inter-observer reliability of both assessors for automated and mUS, MRI, and physical examination, was 66.9%, 72.7%, 95.1%, and 88.9%, respectively. 84.3% of the joints classified as positive on MRI were confirmed by automated ultrasound, 85.5% on mUS, and 36.0 on physical examination. This translated into a sensitivity of 83.5%, 85.5%, and 36.0% for the three methods, respectively. Conclusion: Automated ultrasound is a promising ultrasound method for assessing small joints in patients with inflammatory arthritis.</p>","PeriodicalId":44852,"journal":{"name":"Ultrasound International Open","volume":"4 2","pages":"E61-E68"},"PeriodicalIF":1.3000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/a-0612-7852","citationCount":"2","resultStr":"{\"title\":\"The Value of an Automated Ultrasound System in the Detection of Synovitis.\",\"authors\":\"Ruediger Mueller,&nbsp;Mathias Grunke,&nbsp;Jörg Wendler,&nbsp;Florian Schuch,&nbsp;Karina Hofmann-Preiss,&nbsp;Ina Boettger,&nbsp;Rüdiger Jakobs,&nbsp;Hendrik Schulze-Koops,&nbsp;Johannes von Kempis\",\"doi\":\"10.1055/a-0612-7852\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The detection of joint swelling caused by synovitis is important for the diagnosis of inflammatory arthritis. Ultrasound (US) and MRI have proven to be more sensitive and reliable than physical examination, but they are time-consuming and expensive. The automated breast volume scanner was developed to acquire serial B-mode pictures of the female breast and these can be analyzed in all three dimensions.</p><p><strong>Objectives: </strong>To analyze the value of automated B-mode ultrasound employing the ABVS system in detecting synovitis of the finger joints compared to manual ultrasound (mUS) and physical examination, using MRI as the gold standard.</p><p><strong>Methods: </strong>19 consecutive patients suffering from active rheumatoid (n=15) or psoriatic (n=4) arthritis were included. Automated and mUS were conducted with a linear array (ACUSON S2000™, 11 MHz). Multiplanar reconstruction enabled examination of the images for the presence of synovitis.</p><p><strong>Results: </strong>90% of the hand joints were assessable by automated ultrasound. Automated US detected 12.0, mUS 14.2, MRI 13.4, and clinical examination 4.1 positive joints - i. e. joints with synovitis - on average per patient. The inter-observer reliability of both assessors for automated and mUS, MRI, and physical examination, was 66.9%, 72.7%, 95.1%, and 88.9%, respectively. 84.3% of the joints classified as positive on MRI were confirmed by automated ultrasound, 85.5% on mUS, and 36.0 on physical examination. This translated into a sensitivity of 83.5%, 85.5%, and 36.0% for the three methods, respectively. Conclusion: Automated ultrasound is a promising ultrasound method for assessing small joints in patients with inflammatory arthritis.</p>\",\"PeriodicalId\":44852,\"journal\":{\"name\":\"Ultrasound International Open\",\"volume\":\"4 2\",\"pages\":\"E61-E68\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2018-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1055/a-0612-7852\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound International Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-0612-7852\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2018/7/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-0612-7852","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/7/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 2

摘要

背景:滑膜炎引起的关节肿胀的检测对炎性关节炎的诊断具有重要意义。超声(US)和核磁共振(MRI)已被证明比身体检查更敏感和可靠,但它们既耗时又昂贵。研制了自动乳房体积扫描仪,用于获取女性乳房的连续b模式图像,这些图像可以在三个维度上进行分析。目的:以MRI为金标准,分析采用ABVS系统的自动b超在手指关节滑膜炎诊断中的价值,并与手工超声(mUS)和体格检查进行比较。方法:连续19例活动性类风湿关节炎(n=15)或银屑病关节炎(n=4)患者。使用线性阵列(ACUSON S2000™,11 MHz)进行自动化和mUS。多平面重建使检查图像滑膜炎的存在。结果:90%的手关节可被自动超声评估。自动US检测12.0个,mUS 14.2个,MRI 13.4个,临床检查阳性关节4.1个。关节与滑膜炎-平均每个病人。自动和mUS、MRI和体格检查两种评估者的观察者间信度分别为66.9%、72.7%、95.1%和88.9%。MRI阳性关节的自动超声确诊率为84.3%,mUS确诊率为85.5%,体格检查确诊率为36.0%。这三种方法的灵敏度分别为83.5%、85.5%和36.0%。结论:自动超声是一种很有前途的评估炎性关节炎患者小关节的超声方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Value of an Automated Ultrasound System in the Detection of Synovitis.

Background: The detection of joint swelling caused by synovitis is important for the diagnosis of inflammatory arthritis. Ultrasound (US) and MRI have proven to be more sensitive and reliable than physical examination, but they are time-consuming and expensive. The automated breast volume scanner was developed to acquire serial B-mode pictures of the female breast and these can be analyzed in all three dimensions.

Objectives: To analyze the value of automated B-mode ultrasound employing the ABVS system in detecting synovitis of the finger joints compared to manual ultrasound (mUS) and physical examination, using MRI as the gold standard.

Methods: 19 consecutive patients suffering from active rheumatoid (n=15) or psoriatic (n=4) arthritis were included. Automated and mUS were conducted with a linear array (ACUSON S2000™, 11 MHz). Multiplanar reconstruction enabled examination of the images for the presence of synovitis.

Results: 90% of the hand joints were assessable by automated ultrasound. Automated US detected 12.0, mUS 14.2, MRI 13.4, and clinical examination 4.1 positive joints - i. e. joints with synovitis - on average per patient. The inter-observer reliability of both assessors for automated and mUS, MRI, and physical examination, was 66.9%, 72.7%, 95.1%, and 88.9%, respectively. 84.3% of the joints classified as positive on MRI were confirmed by automated ultrasound, 85.5% on mUS, and 36.0 on physical examination. This translated into a sensitivity of 83.5%, 85.5%, and 36.0% for the three methods, respectively. Conclusion: Automated ultrasound is a promising ultrasound method for assessing small joints in patients with inflammatory arthritis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound International Open
Ultrasound International Open RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
0.00%
发文量
7
审稿时长
12 weeks
期刊最新文献
Congenital coarctation of the aorta: Role of peripheral vascular ultrasound in young hypertensive patients. Lung ultrasound score for the assessment of lung aeration in ARDS patients: comparison of two approaches. Pancreatic ultrasound: An update of measurements, reference values, and variations of the pancreas. Insights Into Modern Undergraduate Ultrasound Education: Prospective Comparison of Digital and Analog Teaching Resources in a Flipped Classroom Concept - The DIvAN Study. Ultrasound elastography: a brief clinical history of an evolving technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1