离子液体在吸收种子X射线显微CT标本制备中的应用

IF 1.8 4区 工程技术 Microscopy Pub Date : 2019-02-01 DOI:10.1093/jmicro/dfy130
Daisuke Yamauchi;Aki Fukuda;Tomonori Nakai;Ichirou Karahara;Miyuki Takeuchi;Daisuke Tamaoki;Tetsuya Tsuda;Katsuhiko Tsunashima;Susumu Kuwabata;Masato Hoshino;Kentaro Uesugi;Akihisa Takeuchi;Yoshio Suzuki;Yoshinobu Mineyuki
{"title":"离子液体在吸收种子X射线显微CT标本制备中的应用","authors":"Daisuke Yamauchi;Aki Fukuda;Tomonori Nakai;Ichirou Karahara;Miyuki Takeuchi;Daisuke Tamaoki;Tetsuya Tsuda;Katsuhiko Tsunashima;Susumu Kuwabata;Masato Hoshino;Kentaro Uesugi;Akihisa Takeuchi;Yoshio Suzuki;Yoshinobu Mineyuki","doi":"10.1093/jmicro/dfy130","DOIUrl":null,"url":null,"abstract":"We developed a novel specimen preparation method for X-ray micro-CT observation of wet biological samples using ionic liquids. Treatment with high concentrations of ionic liquids after osmium tetroxide fixation helped not only to prevent shrinkage but also to maintain the cellular architecture of imbibed Arabidopsis seeds. X-ray micro-CT is one of the most useful techniques to examine 3D cellular architecture inside dry seeds. However, the examination of imbibed seeds is difficult because immersion in water causes a decline in the image quality. Here, we examined the use of ionic liquids for specimen preparation of chemically fixed imbibed seeds of Arabidopsis. We found that treatment with high concentrations of ionic liquids after osmium tetroxide fixation helped not only to prevent the structural damage caused by seed shrinkage, but also to preserve the image quality. Under these conditions, the cellular architecture of seeds was also well maintained.","PeriodicalId":18515,"journal":{"name":"Microscopy","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1093/jmicro/dfy130","citationCount":"2","resultStr":"{\"title\":\"Use of ionic liquid for X-ray micro-CT specimen preparation of imbibed seeds\",\"authors\":\"Daisuke Yamauchi;Aki Fukuda;Tomonori Nakai;Ichirou Karahara;Miyuki Takeuchi;Daisuke Tamaoki;Tetsuya Tsuda;Katsuhiko Tsunashima;Susumu Kuwabata;Masato Hoshino;Kentaro Uesugi;Akihisa Takeuchi;Yoshio Suzuki;Yoshinobu Mineyuki\",\"doi\":\"10.1093/jmicro/dfy130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We developed a novel specimen preparation method for X-ray micro-CT observation of wet biological samples using ionic liquids. Treatment with high concentrations of ionic liquids after osmium tetroxide fixation helped not only to prevent shrinkage but also to maintain the cellular architecture of imbibed Arabidopsis seeds. X-ray micro-CT is one of the most useful techniques to examine 3D cellular architecture inside dry seeds. However, the examination of imbibed seeds is difficult because immersion in water causes a decline in the image quality. Here, we examined the use of ionic liquids for specimen preparation of chemically fixed imbibed seeds of Arabidopsis. We found that treatment with high concentrations of ionic liquids after osmium tetroxide fixation helped not only to prevent the structural damage caused by seed shrinkage, but also to preserve the image quality. Under these conditions, the cellular architecture of seeds was also well maintained.\",\"PeriodicalId\":18515,\"journal\":{\"name\":\"Microscopy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1093/jmicro/dfy130\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microscopy\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/8668076/\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/8668076/","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

我们开发了一种新的样品制备方法,用于使用离子液体对湿生物样品进行X射线显微CT观察。四氧化锇固定后用高浓度离子液体处理不仅有助于防止收缩,而且有助于维持吸收的拟南芥种子的细胞结构。X射线显微CT是检测干种子内部三维细胞结构最有用的技术之一。然而,由于浸泡在水中会导致图像质量下降,因此对吸收的种子进行检查是困难的。在这里,我们研究了离子液体用于化学固定的拟南芥吸收种子的样品制备。我们发现,四氧化锇固定后用高浓度离子液体处理不仅有助于防止种子收缩引起的结构损伤,而且有助于保持图像质量。在这些条件下,种子的细胞结构也得到了很好的维持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Use of ionic liquid for X-ray micro-CT specimen preparation of imbibed seeds
We developed a novel specimen preparation method for X-ray micro-CT observation of wet biological samples using ionic liquids. Treatment with high concentrations of ionic liquids after osmium tetroxide fixation helped not only to prevent shrinkage but also to maintain the cellular architecture of imbibed Arabidopsis seeds. X-ray micro-CT is one of the most useful techniques to examine 3D cellular architecture inside dry seeds. However, the examination of imbibed seeds is difficult because immersion in water causes a decline in the image quality. Here, we examined the use of ionic liquids for specimen preparation of chemically fixed imbibed seeds of Arabidopsis. We found that treatment with high concentrations of ionic liquids after osmium tetroxide fixation helped not only to prevent the structural damage caused by seed shrinkage, but also to preserve the image quality. Under these conditions, the cellular architecture of seeds was also well maintained.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microscopy
Microscopy 工程技术-显微镜技术
自引率
11.10%
发文量
0
审稿时长
>12 weeks
期刊介绍: Microscopy, previously Journal of Electron Microscopy, promotes research combined with any type of microscopy techniques, applied in life and material sciences. Microscopy is the official journal of the Japanese Society of Microscopy.
期刊最新文献
In This Issue Scanning ion-conductance microscopy with a double-barreled nanopipette for topographic imaging of charged chromosomes Operando observation of magnetism in HDD writing heads by spin-polarized scanning electron microscopy Deep convolutional neural network image processing method providing improved signal-to-noise ratios in electron holography Electron transfer in LiMn1.5Ni0.5O4 during charging studied with soft X-ray spectrometry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1