义齿材料对义齿基托载荷传递的影响。

Ramin Mosharraf, Farzad Ziaei, Mahsa Abbasi
{"title":"义齿材料对义齿基托载荷传递的影响。","authors":"Ramin Mosharraf,&nbsp;Farzad Ziaei,&nbsp;Mahsa Abbasi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Pressure transmission under denture bases can vary depending on the denture tooth material. The aim of the present study was to evaluate pressure transmission under denture bases using denture teeth of different materials in direct and indirect tooth contacts.</p><p><strong>Materials and methods: </strong>In this in-vitro study, the pressure transmission generated by five types of denture teeth, including ceramic, nanocomposite, composite-acrylic resin, cross-linked acrylic resin, and polymethyl methacrylate (PMMA), under direct and indirect pressures was evaluated (n=10). The maximum pressure (MPa) was measured using a strain gauge. Data were statistically analyzed with one-way analysis of variance (ANOVA; α=0.05).</p><p><strong>Results: </strong>The denture tooth material had a significant effect on pressure transmission under denture bases (P<0.001). Under direct load, ceramic and PMMA teeth exhibited the maximum and minimum pressures, respectively, contrary to indirect load (P<0.001).</p><p><strong>Conclusions: </strong>Pressure transmission under denture bases significantly varies with the use of different denture tooth materials. Acrylic teeth could be the most favorable choice to reduce the pressure beneath denture bases. Nanocomposite and acrylic resin-composite teeth may be used as alternatives.</p>","PeriodicalId":30286,"journal":{"name":"Journal of Dentistry of Tehran University of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6397739/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of Denture Tooth Material on Load Transmission Under Denture Bases.\",\"authors\":\"Ramin Mosharraf,&nbsp;Farzad Ziaei,&nbsp;Mahsa Abbasi\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Pressure transmission under denture bases can vary depending on the denture tooth material. The aim of the present study was to evaluate pressure transmission under denture bases using denture teeth of different materials in direct and indirect tooth contacts.</p><p><strong>Materials and methods: </strong>In this in-vitro study, the pressure transmission generated by five types of denture teeth, including ceramic, nanocomposite, composite-acrylic resin, cross-linked acrylic resin, and polymethyl methacrylate (PMMA), under direct and indirect pressures was evaluated (n=10). The maximum pressure (MPa) was measured using a strain gauge. Data were statistically analyzed with one-way analysis of variance (ANOVA; α=0.05).</p><p><strong>Results: </strong>The denture tooth material had a significant effect on pressure transmission under denture bases (P<0.001). Under direct load, ceramic and PMMA teeth exhibited the maximum and minimum pressures, respectively, contrary to indirect load (P<0.001).</p><p><strong>Conclusions: </strong>Pressure transmission under denture bases significantly varies with the use of different denture tooth materials. Acrylic teeth could be the most favorable choice to reduce the pressure beneath denture bases. Nanocomposite and acrylic resin-composite teeth may be used as alternatives.</p>\",\"PeriodicalId\":30286,\"journal\":{\"name\":\"Journal of Dentistry of Tehran University of Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6397739/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Dentistry of Tehran University of Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Dentistry of Tehran University of Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:义齿基托下的压力传递随义齿材料的不同而变化。本研究的目的是评估不同材料的义齿在直接和间接牙齿接触时义齿基托下的压力传递。材料与方法:在体外实验中,研究了陶瓷、纳米复合、复合丙烯酸树脂、交联丙烯酸树脂、聚甲基丙烯酸甲酯(PMMA)等5种义齿在直接压力和间接压力作用下的压力传递情况(n=10)。用应变计测量最大压力(MPa)。资料采用单因素方差分析(ANOVA)进行统计学分析;α= 0.05)。结果:义齿材料对义齿基托下压力传递有显著影响(p)结论:义齿基托下压力传递因使用不同义齿材料而有显著差异。丙烯酸牙是减少义齿基托压力的最佳选择。纳米复合牙和丙烯酸树脂复合牙可作为替代品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Denture Tooth Material on Load Transmission Under Denture Bases.

Objectives: Pressure transmission under denture bases can vary depending on the denture tooth material. The aim of the present study was to evaluate pressure transmission under denture bases using denture teeth of different materials in direct and indirect tooth contacts.

Materials and methods: In this in-vitro study, the pressure transmission generated by five types of denture teeth, including ceramic, nanocomposite, composite-acrylic resin, cross-linked acrylic resin, and polymethyl methacrylate (PMMA), under direct and indirect pressures was evaluated (n=10). The maximum pressure (MPa) was measured using a strain gauge. Data were statistically analyzed with one-way analysis of variance (ANOVA; α=0.05).

Results: The denture tooth material had a significant effect on pressure transmission under denture bases (P<0.001). Under direct load, ceramic and PMMA teeth exhibited the maximum and minimum pressures, respectively, contrary to indirect load (P<0.001).

Conclusions: Pressure transmission under denture bases significantly varies with the use of different denture tooth materials. Acrylic teeth could be the most favorable choice to reduce the pressure beneath denture bases. Nanocomposite and acrylic resin-composite teeth may be used as alternatives.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
期刊最新文献
Polymerization Shrinkage of Five Bulk-Fill Composite Resins in Comparison with a Conventional Composite Resin. Effect of Storage Time of a Ceramic Primer on Microshear Bond Strength to Zirconia. Evaluation of the Effect of MTAD on Expression of Enterococcus faecalis Virulence Factors Considering the Role of Different Obturating Materials. Extraskeletal Ewing Sarcoma: Report of an Extremely Rare Case in Temporal Region. Evaluation of the Prevalence of Temporomandibular Joint Involvement in Rheumatoid Arthritis Using Research Diagnostic Criteria for Temporomandibular Disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1