{"title":"前庭测试-旋转椅和动态视力测试。","authors":"Yoav Gimmon, Michael C Schubert","doi":"10.1159/000490270","DOIUrl":null,"url":null,"abstract":"<p><p>The human vestibular system is exquisitely sensitive to detect linear and rotational head acceleration signals, processed in the brainstem and subsequently relayed to the extraocular motor neurons to generate a compensatory eye rotation. This vestibulo-ocular reflex (VOR) ensures clear and stable vision during head rotation, enabling humans to keep gaze on their desired target. In this chapter, we describe the rotary chair - one physiologic measure of the VOR, and the dynamic visual acuity (DVA) test - one behavioral measure of the VOR. Advances in the use of each measure are covered and include establishing normative values, expanding into non-vestibular diagnoses, and broadening the application of each measure. These recent advances in rotary chair and DVA test methods help in extending our knowledge of this 3-dimensional motion sensor.</p>","PeriodicalId":39848,"journal":{"name":"Advances in Oto-Rhino-Laryngology","volume":"82 ","pages":"39-46"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000490270","citationCount":"9","resultStr":"{\"title\":\"Vestibular Testing-Rotary Chair and Dynamic Visual Acuity Tests.\",\"authors\":\"Yoav Gimmon, Michael C Schubert\",\"doi\":\"10.1159/000490270\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The human vestibular system is exquisitely sensitive to detect linear and rotational head acceleration signals, processed in the brainstem and subsequently relayed to the extraocular motor neurons to generate a compensatory eye rotation. This vestibulo-ocular reflex (VOR) ensures clear and stable vision during head rotation, enabling humans to keep gaze on their desired target. In this chapter, we describe the rotary chair - one physiologic measure of the VOR, and the dynamic visual acuity (DVA) test - one behavioral measure of the VOR. Advances in the use of each measure are covered and include establishing normative values, expanding into non-vestibular diagnoses, and broadening the application of each measure. These recent advances in rotary chair and DVA test methods help in extending our knowledge of this 3-dimensional motion sensor.</p>\",\"PeriodicalId\":39848,\"journal\":{\"name\":\"Advances in Oto-Rhino-Laryngology\",\"volume\":\"82 \",\"pages\":\"39-46\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1159/000490270\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Oto-Rhino-Laryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000490270\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/1/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Oto-Rhino-Laryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000490270","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
Vestibular Testing-Rotary Chair and Dynamic Visual Acuity Tests.
The human vestibular system is exquisitely sensitive to detect linear and rotational head acceleration signals, processed in the brainstem and subsequently relayed to the extraocular motor neurons to generate a compensatory eye rotation. This vestibulo-ocular reflex (VOR) ensures clear and stable vision during head rotation, enabling humans to keep gaze on their desired target. In this chapter, we describe the rotary chair - one physiologic measure of the VOR, and the dynamic visual acuity (DVA) test - one behavioral measure of the VOR. Advances in the use of each measure are covered and include establishing normative values, expanding into non-vestibular diagnoses, and broadening the application of each measure. These recent advances in rotary chair and DVA test methods help in extending our knowledge of this 3-dimensional motion sensor.
期刊介绍:
Material for each volume in this series has been skillfully selected to document the most active areas of otorhinolaryngology and related specialties, such as neuro-otology and oncology. The series reproduces results from basic research and clinical studies pertaining to the pathophysiology, diagnosis, clinical symptoms, course, prognosis and therapy of a variety of ear, nose and throat disorders. The numerous papers correlating basic research findings and clinical applications are of immense value to all specialists engaged in the ongoing efforts to improve management of these disorders. Acting as a voice for its field, the series has also been instrumental in developing subspecialities into established specialities.