Alfredo E Rodriguez, Miguel Larribau, Carlos Fernandez-Pereira, Jorge Iravedra, Omar Santaera, Carlos Haiek, Juan Lloberas, Mario Montoya, Elias Sisu, Marcelo Menendez, Hernan Pavlovsky, Alfredo M Rodriguez-Granillo, Juan Mieres, Graciela Romero, Zheng Ming, William Pan, David Antoniucci
{"title":"来自观察性、多中心、前瞻性和对照注册的一年随访结果:华尔兹所有患者研究。","authors":"Alfredo E Rodriguez, Miguel Larribau, Carlos Fernandez-Pereira, Jorge Iravedra, Omar Santaera, Carlos Haiek, Juan Lloberas, Mario Montoya, Elias Sisu, Marcelo Menendez, Hernan Pavlovsky, Alfredo M Rodriguez-Granillo, Juan Mieres, Graciela Romero, Zheng Ming, William Pan, David Antoniucci","doi":"10.1177/1179546819854059","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate 1-year follow-up results in an all \"comers\" population treated with a new cobalt chromium bare-metal stent (BMS) design. Since August 2016 to March 2017, 201 (9.7% of screening population) consecutive patients undergoing coronary stent implantation in 11 centers in Argentina were prospectively included in our registry. The inclusion criteria were multiple-vessel disease and/or unprotected left main disease, acute coronary syndromes (ACS) with at least one severe (⩾70%) stenosis in any of major epicardial vessel. In-stent restenosis, protected left main stenosis, or impossibility to receive dual-antiplatelet therapy was an exclusion criterion. Major adverse cardiac events (MACE) were the primary endpoint and included cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR); also, all components of the primary endpoint were separately analyzed. Completeness of revascularization was analyzed as post hoc data using residual SYNTAX or ERACI risk scores. Demographic characteristics showed that 6.5% of patients were very elderly, 22.5% have diabetes, 47% have multiple-vessel disease, 67% have ACS, and 32% have ST elevation MI. At a mean of 376 ± 18.1 days of follow-up, MACE was observed in 10.4% of patients: death + MI + cardiovascular accident (CVA) in 3% (6 of 201) and cardiac death + MI + CVA in 1.5% (3 of 201). Residual ERACI score ⩽5 was associated with 98% of event-free survival (<i>P</i> < .04). In conclusion, this prospective, multicenter, and observational all-comers registry with this novel BMS design showed a low incidence of adverse events at 1 year mainly due to coronary restenosis.</p>","PeriodicalId":10419,"journal":{"name":"Clinical Medicine Insights. Cardiology","volume":"13 ","pages":"1179546819854059"},"PeriodicalIF":2.3000,"publicationDate":"2019-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1179546819854059","citationCount":"2","resultStr":"{\"title\":\"One-Year Follow-Up Results From the Observational, Multicenter, Prospective, and Controlled Registry: The WALTZ All-Comers Study.\",\"authors\":\"Alfredo E Rodriguez, Miguel Larribau, Carlos Fernandez-Pereira, Jorge Iravedra, Omar Santaera, Carlos Haiek, Juan Lloberas, Mario Montoya, Elias Sisu, Marcelo Menendez, Hernan Pavlovsky, Alfredo M Rodriguez-Granillo, Juan Mieres, Graciela Romero, Zheng Ming, William Pan, David Antoniucci\",\"doi\":\"10.1177/1179546819854059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to evaluate 1-year follow-up results in an all \\\"comers\\\" population treated with a new cobalt chromium bare-metal stent (BMS) design. Since August 2016 to March 2017, 201 (9.7% of screening population) consecutive patients undergoing coronary stent implantation in 11 centers in Argentina were prospectively included in our registry. The inclusion criteria were multiple-vessel disease and/or unprotected left main disease, acute coronary syndromes (ACS) with at least one severe (⩾70%) stenosis in any of major epicardial vessel. In-stent restenosis, protected left main stenosis, or impossibility to receive dual-antiplatelet therapy was an exclusion criterion. Major adverse cardiac events (MACE) were the primary endpoint and included cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR); also, all components of the primary endpoint were separately analyzed. Completeness of revascularization was analyzed as post hoc data using residual SYNTAX or ERACI risk scores. Demographic characteristics showed that 6.5% of patients were very elderly, 22.5% have diabetes, 47% have multiple-vessel disease, 67% have ACS, and 32% have ST elevation MI. At a mean of 376 ± 18.1 days of follow-up, MACE was observed in 10.4% of patients: death + MI + cardiovascular accident (CVA) in 3% (6 of 201) and cardiac death + MI + CVA in 1.5% (3 of 201). Residual ERACI score ⩽5 was associated with 98% of event-free survival (<i>P</i> < .04). In conclusion, this prospective, multicenter, and observational all-comers registry with this novel BMS design showed a low incidence of adverse events at 1 year mainly due to coronary restenosis.</p>\",\"PeriodicalId\":10419,\"journal\":{\"name\":\"Clinical Medicine Insights. Cardiology\",\"volume\":\"13 \",\"pages\":\"1179546819854059\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2019-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1179546819854059\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Medicine Insights. Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1179546819854059\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Medicine Insights. Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1179546819854059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
One-Year Follow-Up Results From the Observational, Multicenter, Prospective, and Controlled Registry: The WALTZ All-Comers Study.
The aim of this study was to evaluate 1-year follow-up results in an all "comers" population treated with a new cobalt chromium bare-metal stent (BMS) design. Since August 2016 to March 2017, 201 (9.7% of screening population) consecutive patients undergoing coronary stent implantation in 11 centers in Argentina were prospectively included in our registry. The inclusion criteria were multiple-vessel disease and/or unprotected left main disease, acute coronary syndromes (ACS) with at least one severe (⩾70%) stenosis in any of major epicardial vessel. In-stent restenosis, protected left main stenosis, or impossibility to receive dual-antiplatelet therapy was an exclusion criterion. Major adverse cardiac events (MACE) were the primary endpoint and included cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR); also, all components of the primary endpoint were separately analyzed. Completeness of revascularization was analyzed as post hoc data using residual SYNTAX or ERACI risk scores. Demographic characteristics showed that 6.5% of patients were very elderly, 22.5% have diabetes, 47% have multiple-vessel disease, 67% have ACS, and 32% have ST elevation MI. At a mean of 376 ± 18.1 days of follow-up, MACE was observed in 10.4% of patients: death + MI + cardiovascular accident (CVA) in 3% (6 of 201) and cardiac death + MI + CVA in 1.5% (3 of 201). Residual ERACI score ⩽5 was associated with 98% of event-free survival (P < .04). In conclusion, this prospective, multicenter, and observational all-comers registry with this novel BMS design showed a low incidence of adverse events at 1 year mainly due to coronary restenosis.