mri引导下经皮介入治疗的远程驱动针驱动装置。

Di Wu, Gang Li, Niravkumar Patel, Jiawen Yan, Reza Monfaredi, Kevin Cleary, Iulian Iordachita
{"title":"mri引导下经皮介入治疗的远程驱动针驱动装置。","authors":"Di Wu,&nbsp;Gang Li,&nbsp;Niravkumar Patel,&nbsp;Jiawen Yan,&nbsp;Reza Monfaredi,&nbsp;Kevin Cleary,&nbsp;Iulian Iordachita","doi":"10.1109/ismr.2019.8710176","DOIUrl":null,"url":null,"abstract":"<p><p>In this paper we introduce a remotely actuated MRI-compatible needle driving device for pain injections in the lower back. This device is able to manipulate the needle inside the closed-bore MRI scanner under the control of the interventional radiologist inside both the scanner room and the console room. The device consists of a 2 degrees of freedom (DOF) needle driver and an actuation box. The 2-DOF needle driver is placed inside the scanner bore and driven by the actuation box settled at the end of the table through a beaded chain transmission. This novel remote actuation design could reduce the weight and profile of the needle driver that is mounted on the patient, as well as minimize the potential imaging noise introduced by the actuation electronics. The actuation box is designed to perform needle intervention in both manual and motorized fashion by utilizing a mode switch mechanism. A mechanical hard stop is also incorporated to improve the device's safety. The bench-top accuracy evaluation of the device demonstrated a small mean needle placement error (<i><</i> 1 mm) in a phantom study.</p>","PeriodicalId":72029,"journal":{"name":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/ismr.2019.8710176","citationCount":"10","resultStr":"{\"title\":\"Remotely Actuated Needle Driving Device for MRI-Guided Percutaneous Interventions.\",\"authors\":\"Di Wu,&nbsp;Gang Li,&nbsp;Niravkumar Patel,&nbsp;Jiawen Yan,&nbsp;Reza Monfaredi,&nbsp;Kevin Cleary,&nbsp;Iulian Iordachita\",\"doi\":\"10.1109/ismr.2019.8710176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this paper we introduce a remotely actuated MRI-compatible needle driving device for pain injections in the lower back. This device is able to manipulate the needle inside the closed-bore MRI scanner under the control of the interventional radiologist inside both the scanner room and the console room. The device consists of a 2 degrees of freedom (DOF) needle driver and an actuation box. The 2-DOF needle driver is placed inside the scanner bore and driven by the actuation box settled at the end of the table through a beaded chain transmission. This novel remote actuation design could reduce the weight and profile of the needle driver that is mounted on the patient, as well as minimize the potential imaging noise introduced by the actuation electronics. The actuation box is designed to perform needle intervention in both manual and motorized fashion by utilizing a mode switch mechanism. A mechanical hard stop is also incorporated to improve the device's safety. The bench-top accuracy evaluation of the device demonstrated a small mean needle placement error (<i><</i> 1 mm) in a phantom study.</p>\",\"PeriodicalId\":72029,\"journal\":{\"name\":\"... International Symposium on Medical Robotics. International Symposium on Medical Robotics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/ismr.2019.8710176\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"... International Symposium on Medical Robotics. International Symposium on Medical Robotics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ismr.2019.8710176\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/5/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"... International Symposium on Medical Robotics. International Symposium on Medical Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ismr.2019.8710176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/5/9 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

在本文中,我们介绍了一种用于下背部疼痛注射的远程驱动mri兼容针驱动装置。该装置能够在扫描室和控制室的介入放射科医生的控制下操纵闭孔MRI扫描仪内的针头。该装置由一个2自由度(DOF)的针驱动器和一个驱动箱组成。2-DOF针驱动器放置在扫描孔内,并通过串珠链传动由位于表端的驱动箱驱动。这种新颖的远程驱动设计可以减少安装在患者身上的针驱动器的重量和外形,并最大限度地减少由驱动电子设备引入的潜在成像噪声。驱动箱设计用于通过使用模式切换机构以手动和电动方式进行针干预。机械硬停止也被纳入,以提高设备的安全性。该装置的台架精度评估显示,在幻影研究中,针的平均放置误差很小(1毫米)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Remotely Actuated Needle Driving Device for MRI-Guided Percutaneous Interventions.

In this paper we introduce a remotely actuated MRI-compatible needle driving device for pain injections in the lower back. This device is able to manipulate the needle inside the closed-bore MRI scanner under the control of the interventional radiologist inside both the scanner room and the console room. The device consists of a 2 degrees of freedom (DOF) needle driver and an actuation box. The 2-DOF needle driver is placed inside the scanner bore and driven by the actuation box settled at the end of the table through a beaded chain transmission. This novel remote actuation design could reduce the weight and profile of the needle driver that is mounted on the patient, as well as minimize the potential imaging noise introduced by the actuation electronics. The actuation box is designed to perform needle intervention in both manual and motorized fashion by utilizing a mode switch mechanism. A mechanical hard stop is also incorporated to improve the device's safety. The bench-top accuracy evaluation of the device demonstrated a small mean needle placement error (< 1 mm) in a phantom study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Towards a Robotically Steerable Laser Ablation Probe. Artificial intelligence (AI) for minimally invasive robotics Optical Fiber -Based Needle Shape Sensing: Three-channel Single Core vs. Multicore Approaches. Brain-Mimicking Phantom for Photoablation and Visualization. Modeling and Operator Control of a Robotic Tool for Bidirectional Manipulation in Targeted Prostate Biopsy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1