使用 FCMPASS 软件进行小颗粒荧光和光散射校准。

Q1 Health Professions Current Protocols in Cytometry Pub Date : 2020-09-01 DOI:10.1002/cpcy.79
Joshua A Welsh, Jennifer C Jones
{"title":"使用 FCMPASS 软件进行小颗粒荧光和光散射校准。","authors":"Joshua A Welsh, Jennifer C Jones","doi":"10.1002/cpcy.79","DOIUrl":null,"url":null,"abstract":"<p><p>Use of flow cytometry to analyze small particles has been implemented for several decades. More recently, small particle analysis has become increasingly utilized owing to the increased sensitivity of conventional and commercially available flow cytometers along with growing interest in small particles such as extracellular vesicles (EVs). Despite an increase in small particle flow cytometry utilization, a lack of standardization in data reporting has resulted in a growing body of literature regarding EVs that cannot be easily interpreted, validated, or reproduced. Methods for fluorescence and light scatter standardization are well established, and the reagents to perform these analyses are commercially available. Here, we describe FCM<sub>PASS</sub> , a software package for performing fluorescence and light scatter calibration of small particles while generating standard reports conforming to the MIFlowCyt-EV standard reporting framework. This article covers the workflow of implementing calibration using FCM<sub>PASS</sub> as follows: acquisition of fluorescence and light scatter calibration materials, cataloguing the reference materials for use in the software, creating cytometer databases and datasets to associate calibration data and fcs files, importing fcs files for calibration, inputting fluorescence calibration parameters, inputting light scatter calibration parameters, and applying the calibration to fcs files. Published 2020. U.S. Government. Basic Protocol 1: Acquisition and gating of light scatter calibration materials Basic Protocol 2: Acquisition and gating of fluorescence calibration materials Alternate Protocol: Cross-calibration of fluorescence reference materials Basic Protocol 3: Cataloguing light scatter calibration materials Basic Protocol 4: Cataloguing fluorescence calibration materials Basic Protocol 5: Creating cytometer databases and datasets Basic Protocol 6: Importing fcs files Basic Protocol 7: Fluorescence calibration Basic Protocol 8: Light scatter calibration Basic Protocol 9: Performing and reporting fcs file calibration.</p>","PeriodicalId":11020,"journal":{"name":"Current Protocols in Cytometry","volume":"94 1","pages":"e79"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8623744/pdf/nihms-1642108.pdf","citationCount":"0","resultStr":"{\"title\":\"Small Particle Fluorescence and Light Scatter Calibration Using FCM<sub>PASS</sub> Software.\",\"authors\":\"Joshua A Welsh, Jennifer C Jones\",\"doi\":\"10.1002/cpcy.79\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Use of flow cytometry to analyze small particles has been implemented for several decades. More recently, small particle analysis has become increasingly utilized owing to the increased sensitivity of conventional and commercially available flow cytometers along with growing interest in small particles such as extracellular vesicles (EVs). Despite an increase in small particle flow cytometry utilization, a lack of standardization in data reporting has resulted in a growing body of literature regarding EVs that cannot be easily interpreted, validated, or reproduced. Methods for fluorescence and light scatter standardization are well established, and the reagents to perform these analyses are commercially available. Here, we describe FCM<sub>PASS</sub> , a software package for performing fluorescence and light scatter calibration of small particles while generating standard reports conforming to the MIFlowCyt-EV standard reporting framework. This article covers the workflow of implementing calibration using FCM<sub>PASS</sub> as follows: acquisition of fluorescence and light scatter calibration materials, cataloguing the reference materials for use in the software, creating cytometer databases and datasets to associate calibration data and fcs files, importing fcs files for calibration, inputting fluorescence calibration parameters, inputting light scatter calibration parameters, and applying the calibration to fcs files. Published 2020. U.S. Government. Basic Protocol 1: Acquisition and gating of light scatter calibration materials Basic Protocol 2: Acquisition and gating of fluorescence calibration materials Alternate Protocol: Cross-calibration of fluorescence reference materials Basic Protocol 3: Cataloguing light scatter calibration materials Basic Protocol 4: Cataloguing fluorescence calibration materials Basic Protocol 5: Creating cytometer databases and datasets Basic Protocol 6: Importing fcs files Basic Protocol 7: Fluorescence calibration Basic Protocol 8: Light scatter calibration Basic Protocol 9: Performing and reporting fcs file calibration.</p>\",\"PeriodicalId\":11020,\"journal\":{\"name\":\"Current Protocols in Cytometry\",\"volume\":\"94 1\",\"pages\":\"e79\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8623744/pdf/nihms-1642108.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Protocols in Cytometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1002/cpcy.79\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Protocols in Cytometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/cpcy.79","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

摘要

使用流式细胞仪分析小颗粒已有几十年的历史。最近,由于传统和市售流式细胞仪的灵敏度提高,加上人们对细胞外囊泡 (EV) 等小颗粒的兴趣与日俱增,小颗粒分析的应用越来越广泛。尽管小颗粒流式细胞仪的应用越来越广泛,但由于数据报告缺乏标准化,导致有关 EVs 的文献越来越多,而这些文献却不容易解释、验证或复制。荧光和光散射标准化的方法已经非常成熟,进行这些分析的试剂也可以在市场上买到。在此,我们介绍 FCMPASS 软件包,它可对小颗粒进行荧光和光散射校准,同时生成符合 MIFlowCyt-EV 标准报告框架的标准报告。本文介绍了使用 FCMPASS 实施校准的工作流程如下:获取荧光和光散射校准材料、为软件中使用的参考材料编目、创建细胞仪数据库和数据集以关联校准数据和 fcs 文件、导入 fcs 文件进行校准、输入荧光校准参数、输入光散射校准参数以及将校准应用于 fcs 文件。2020 年出版。美国政府。基本规程 1:光散射校准材料的获取和选通 基本规程 2:荧光校准材料的获取和选通 替代规程:基本规程 3:光散射校准材料编目 基本规程 4:荧光校准材料编目 基本规程 5:创建细胞仪数据库和数据集 基本规程 6:导入 fcs 文件 基本规程 7:荧光校准 基本规程 8:光散射校准 基本规程 9:执行和报告 fcs 文件校准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Small Particle Fluorescence and Light Scatter Calibration Using FCMPASS Software.

Use of flow cytometry to analyze small particles has been implemented for several decades. More recently, small particle analysis has become increasingly utilized owing to the increased sensitivity of conventional and commercially available flow cytometers along with growing interest in small particles such as extracellular vesicles (EVs). Despite an increase in small particle flow cytometry utilization, a lack of standardization in data reporting has resulted in a growing body of literature regarding EVs that cannot be easily interpreted, validated, or reproduced. Methods for fluorescence and light scatter standardization are well established, and the reagents to perform these analyses are commercially available. Here, we describe FCMPASS , a software package for performing fluorescence and light scatter calibration of small particles while generating standard reports conforming to the MIFlowCyt-EV standard reporting framework. This article covers the workflow of implementing calibration using FCMPASS as follows: acquisition of fluorescence and light scatter calibration materials, cataloguing the reference materials for use in the software, creating cytometer databases and datasets to associate calibration data and fcs files, importing fcs files for calibration, inputting fluorescence calibration parameters, inputting light scatter calibration parameters, and applying the calibration to fcs files. Published 2020. U.S. Government. Basic Protocol 1: Acquisition and gating of light scatter calibration materials Basic Protocol 2: Acquisition and gating of fluorescence calibration materials Alternate Protocol: Cross-calibration of fluorescence reference materials Basic Protocol 3: Cataloguing light scatter calibration materials Basic Protocol 4: Cataloguing fluorescence calibration materials Basic Protocol 5: Creating cytometer databases and datasets Basic Protocol 6: Importing fcs files Basic Protocol 7: Fluorescence calibration Basic Protocol 8: Light scatter calibration Basic Protocol 9: Performing and reporting fcs file calibration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Protocols in Cytometry
Current Protocols in Cytometry Health Professions-Medical Laboratory Technology
自引率
0.00%
发文量
0
期刊介绍: Published in affiliation with the International Society for Advancement of Cytometry, Current Protocols in Cytometry is a "best practices" collection that distills and organizes the absolute latest techniques from the top cytometry labs and specialists worldwide. It is the most complete set of peer-reviewed protocols for flow and image cytometry available.
期刊最新文献
Issue Information Detection and Sorting of Extracellular Vesicles and Viruses Using nanoFACS Live Imaging of the Lung Small Particle Fluorescence and Light Scatter Calibration Using FCMPASS Software. Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1