金属注射成型与计算机数控制造金属支架槽位尺寸及平行度的比较。

IF 1.9 3区 医学 Q1 Dentistry Korean Journal of Orthodontics Pub Date : 2020-11-25 DOI:10.4041/kjod.2020.50.6.401
Jae-Sung Park, In-Tae Song, Jae-Hee Bae, Soo-Min Gil, Kyung-Hwa Kang
{"title":"金属注射成型与计算机数控制造金属支架槽位尺寸及平行度的比较。","authors":"Jae-Sung Park,&nbsp;In-Tae Song,&nbsp;Jae-Hee Bae,&nbsp;Soo-Min Gil,&nbsp;Kyung-Hwa Kang","doi":"10.4041/kjod.2020.50.6.401","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate and compare the slot sizes and parallelism of metal injection molding (MIM) and computerized numerical control (CNC) brackets.</p><p><strong>Methods: </strong>The following four MIM bracket series with 0.022-inch (in) slots were selected for investigation: Di MIM mini Twin (Ortho Organizers), Mini Diamond Roth (Ormco), Gemini MBT (3M Unitek), and Formula R Roth (Tomy). The following four CNC bracket series with 0.022-in slots were selected for investigation: Econoline MBT (Adenta), Legend mini MBT (GC Orthodontics), Crown mini MBT (Adenta), and Evolve MBT (DB Orthodontics). The slot dimensions were measured using an optical microscope (XTCam-D310M; Mitutoyo) with a resolution of 1 μm. The results were statistically analyzed using one-way analysis of variance and the Tukey <i>post-hoc</i> test with a significance level of 0.05.</p><p><strong>Results: </strong>The results indicated that all the investigated slot sizes were oversized with respect to the manufacturers' specifications (0.022 in). Among the eight bracket series, the Di MIM bracket (MIM) was the most oversized by 10.4%, whereas the Evolve bracket (CNC) was the least oversized by 2.6%. The slots in seven of the bracket series had divergent walls instead of parallel ones. The Evolve bracket alone had parallel slot walls.</p><p><strong>Conclusions: </strong>Regardless of the manufacturing method, all the slot sizes of the brackets investigated in this study were significantly oversized; most of the slot walls were nonparallel, except for those of the Evolve bracket. This study could not establish that the CNC method was more accurate than the MIM method in manufacturing bracket slots.</p>","PeriodicalId":49934,"journal":{"name":"Korean Journal of Orthodontics","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2020-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/af/40/KJOD-50-401.PMC7642229.pdf","citationCount":"2","resultStr":"{\"title\":\"Comparison of slot sizes and parallelism of metal brackets manufactured through metal injection molding and computerized numerical control.\",\"authors\":\"Jae-Sung Park,&nbsp;In-Tae Song,&nbsp;Jae-Hee Bae,&nbsp;Soo-Min Gil,&nbsp;Kyung-Hwa Kang\",\"doi\":\"10.4041/kjod.2020.50.6.401\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate and compare the slot sizes and parallelism of metal injection molding (MIM) and computerized numerical control (CNC) brackets.</p><p><strong>Methods: </strong>The following four MIM bracket series with 0.022-inch (in) slots were selected for investigation: Di MIM mini Twin (Ortho Organizers), Mini Diamond Roth (Ormco), Gemini MBT (3M Unitek), and Formula R Roth (Tomy). The following four CNC bracket series with 0.022-in slots were selected for investigation: Econoline MBT (Adenta), Legend mini MBT (GC Orthodontics), Crown mini MBT (Adenta), and Evolve MBT (DB Orthodontics). The slot dimensions were measured using an optical microscope (XTCam-D310M; Mitutoyo) with a resolution of 1 μm. The results were statistically analyzed using one-way analysis of variance and the Tukey <i>post-hoc</i> test with a significance level of 0.05.</p><p><strong>Results: </strong>The results indicated that all the investigated slot sizes were oversized with respect to the manufacturers' specifications (0.022 in). Among the eight bracket series, the Di MIM bracket (MIM) was the most oversized by 10.4%, whereas the Evolve bracket (CNC) was the least oversized by 2.6%. The slots in seven of the bracket series had divergent walls instead of parallel ones. The Evolve bracket alone had parallel slot walls.</p><p><strong>Conclusions: </strong>Regardless of the manufacturing method, all the slot sizes of the brackets investigated in this study were significantly oversized; most of the slot walls were nonparallel, except for those of the Evolve bracket. This study could not establish that the CNC method was more accurate than the MIM method in manufacturing bracket slots.</p>\",\"PeriodicalId\":49934,\"journal\":{\"name\":\"Korean Journal of Orthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2020-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/af/40/KJOD-50-401.PMC7642229.pdf\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Orthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4041/kjod.2020.50.6.401\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4041/kjod.2020.50.6.401","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 2

摘要

目的:研究和比较金属注射成型(MIM)和计算机数控(CNC)支架的槽位尺寸和平行度。方法:选择0.022英寸(in)槽位MIM支架系列:Di MIM mini Twin (Ortho organizer)、mini Diamond Roth (Ormco)、Gemini MBT (3M Unitek)和Formula R Roth (Tomy)。选择4个0.022 in槽位的数控支架系列:Econoline MBT (Adenta)、Legend mini MBT (GC Orthodontics)、Crown mini MBT (Adenta)和Evolve MBT (DB Orthodontics)。采用光学显微镜(XTCam-D310M;Mitutoyo),分辨率为1 μm。结果采用单因素方差分析和Tukey事后检验进行统计学分析,显著性水平为0.05。结果:结果表明,所有调查的槽尺寸都超过了制造商的规格(0.022英寸)。在8个支架系列中,Di MIM支架(MIM)的尺寸最大,为10.4%,而Evolve支架(CNC)的尺寸最小,为2.6%。在支架系列中,有七个槽的壁是发散的,而不是平行的。仅Evolve支架就有平行槽壁。结论:无论制作方法如何,本研究中调查的所有托槽尺寸都显着过大;除了Evolve支架外,大多数槽壁都是非平行的。本研究不能证明CNC方法比MIM方法加工支架槽的精度更高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comparison of slot sizes and parallelism of metal brackets manufactured through metal injection molding and computerized numerical control.

Objective: To investigate and compare the slot sizes and parallelism of metal injection molding (MIM) and computerized numerical control (CNC) brackets.

Methods: The following four MIM bracket series with 0.022-inch (in) slots were selected for investigation: Di MIM mini Twin (Ortho Organizers), Mini Diamond Roth (Ormco), Gemini MBT (3M Unitek), and Formula R Roth (Tomy). The following four CNC bracket series with 0.022-in slots were selected for investigation: Econoline MBT (Adenta), Legend mini MBT (GC Orthodontics), Crown mini MBT (Adenta), and Evolve MBT (DB Orthodontics). The slot dimensions were measured using an optical microscope (XTCam-D310M; Mitutoyo) with a resolution of 1 μm. The results were statistically analyzed using one-way analysis of variance and the Tukey post-hoc test with a significance level of 0.05.

Results: The results indicated that all the investigated slot sizes were oversized with respect to the manufacturers' specifications (0.022 in). Among the eight bracket series, the Di MIM bracket (MIM) was the most oversized by 10.4%, whereas the Evolve bracket (CNC) was the least oversized by 2.6%. The slots in seven of the bracket series had divergent walls instead of parallel ones. The Evolve bracket alone had parallel slot walls.

Conclusions: Regardless of the manufacturing method, all the slot sizes of the brackets investigated in this study were significantly oversized; most of the slot walls were nonparallel, except for those of the Evolve bracket. This study could not establish that the CNC method was more accurate than the MIM method in manufacturing bracket slots.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Orthodontics
Korean Journal of Orthodontics Dentistry-Orthodontics
CiteScore
2.60
自引率
10.50%
发文量
48
审稿时长
3 months
期刊介绍: The Korean Journal of Orthodontics (KJO) is an international, open access, peer reviewed journal published in January, March, May, July, September, and November each year. It was first launched in 1970 and, as the official scientific publication of Korean Association of Orthodontists, KJO aims to publish high quality clinical and scientific original research papers in all areas related to orthodontics and dentofacial orthopedics. Specifically, its interest focuses on evidence-based investigations of contemporary diagnostic procedures and treatment techniques, expanding to significant clinical reports of diverse treatment approaches. The scope of KJO covers all areas of orthodontics and dentofacial orthopedics including successful diagnostic procedures and treatment planning, growth and development of the face and its clinical implications, appliance designs, biomechanics, TMJ disorders and adult treatment. Specifically, its latest interest focuses on skeletal anchorage devices, orthodontic appliance and biomaterials, 3 dimensional imaging techniques utilized for dentofacial diagnosis and treatment planning, and orthognathic surgery to correct skeletal disharmony in association of orthodontic treatment.
期刊最新文献
Clinical expression of programmed maxillary buccal expansion and buccolingual crown inclination with Invisalign EX30 and SmartTrack aligners and the effect of 1-week vs. 2-week aligner change regimes: A retrospective cohort study. Orthodontic treatment in a patient with Moebius syndrome: A case report. Clinical effects of different prescriptions on the inclination of maxillary and mandibular incisors by using passive self-ligating brackets. Enhancement of bioactivity and osseointegration in Ti-6Al-4V orthodontic mini-screws coated with calcium phosphate on the TiO2 nanotube layer. Crown-root angulations of the maxillary anterior teeth according to malocclusions: A cone-beam computed tomography study in Korean population.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1