在全膝关节置换术中,人口统计学数据比数字x线摄影模板更能预测部件尺寸。

IF 4.1 Q1 ORTHOPEDICS Knee Surgery & Related Research Pub Date : 2020-11-23 DOI:10.1186/s43019-020-00075-y
Stephen J Wallace, Michael P Murphy, Corey J Schiffman, William J Hopkinson, Nicholas M Brown
{"title":"在全膝关节置换术中,人口统计学数据比数字x线摄影模板更能预测部件尺寸。","authors":"Stephen J Wallace,&nbsp;Michael P Murphy,&nbsp;Corey J Schiffman,&nbsp;William J Hopkinson,&nbsp;Nicholas M Brown","doi":"10.1186/s43019-020-00075-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Preoperative radiographic templating for total knee arthroplasty (TKA) has been shown to be inaccurate. Patient demographic data, such as gender, height, weight, age, and race, may be more predictive of implanted component size in TKA.</p><p><strong>Materials and methods: </strong>A multivariate linear regression model was designed to predict implanted femoral and tibial component size using demographic data along a consecutive series of 201 patients undergoing index TKA. Traditional, two-dimensional, radiographic templating was compared to demographic-based regression predictions on a prospective 181 consecutive patients undergoing index TKA in their ability to accurately predict intraoperative implanted sizes. Surgeons were blinded of any predictions.</p><p><strong>Results: </strong>Patient gender, height, weight, age, and ethnicity/race were predictive of implanted TKA component size. The regression model more accurately predicted implanted component size compared to radiographically templated sizes for both the femoral (P = 0.04) and tibial (P < 0.01) components. The regression model exactly predicted femoral and tibial component sizes in 43.7 and 43.7% of cases, was within one size 90.1 and 95.6% of the time, and was within two sizes in every case. Radiographic templating exactly predicted 35.4 and 36.5% of cases, was within one size 86.2 and 85.1% of the time, and varied up to four sizes for both the femoral and tibial components. The regression model averaged within 0.66 and 0.61 sizes, versus 0.81 and 0.81 sizes for radiographic templating for femoral and tibial components.</p><p><strong>Conclusions: </strong>A demographic-based regression model was created based on patient-specific demographic data to predict femoral and tibial TKA component sizes. In a prospective patient series, the regression model more accurately and precisely predicted implanted component sizes compared to radiographic templating.</p><p><strong>Level of evidence: </strong>Prospective cohort, level II.</p>","PeriodicalId":17886,"journal":{"name":"Knee Surgery & Related Research","volume":"32 1","pages":"63"},"PeriodicalIF":4.1000,"publicationDate":"2020-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s43019-020-00075-y","citationCount":"12","resultStr":"{\"title\":\"Demographic data is more predictive of component size than digital radiographic templating in total knee arthroplasty.\",\"authors\":\"Stephen J Wallace,&nbsp;Michael P Murphy,&nbsp;Corey J Schiffman,&nbsp;William J Hopkinson,&nbsp;Nicholas M Brown\",\"doi\":\"10.1186/s43019-020-00075-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Preoperative radiographic templating for total knee arthroplasty (TKA) has been shown to be inaccurate. Patient demographic data, such as gender, height, weight, age, and race, may be more predictive of implanted component size in TKA.</p><p><strong>Materials and methods: </strong>A multivariate linear regression model was designed to predict implanted femoral and tibial component size using demographic data along a consecutive series of 201 patients undergoing index TKA. Traditional, two-dimensional, radiographic templating was compared to demographic-based regression predictions on a prospective 181 consecutive patients undergoing index TKA in their ability to accurately predict intraoperative implanted sizes. Surgeons were blinded of any predictions.</p><p><strong>Results: </strong>Patient gender, height, weight, age, and ethnicity/race were predictive of implanted TKA component size. The regression model more accurately predicted implanted component size compared to radiographically templated sizes for both the femoral (P = 0.04) and tibial (P < 0.01) components. The regression model exactly predicted femoral and tibial component sizes in 43.7 and 43.7% of cases, was within one size 90.1 and 95.6% of the time, and was within two sizes in every case. Radiographic templating exactly predicted 35.4 and 36.5% of cases, was within one size 86.2 and 85.1% of the time, and varied up to four sizes for both the femoral and tibial components. The regression model averaged within 0.66 and 0.61 sizes, versus 0.81 and 0.81 sizes for radiographic templating for femoral and tibial components.</p><p><strong>Conclusions: </strong>A demographic-based regression model was created based on patient-specific demographic data to predict femoral and tibial TKA component sizes. In a prospective patient series, the regression model more accurately and precisely predicted implanted component sizes compared to radiographic templating.</p><p><strong>Level of evidence: </strong>Prospective cohort, level II.</p>\",\"PeriodicalId\":17886,\"journal\":{\"name\":\"Knee Surgery & Related Research\",\"volume\":\"32 1\",\"pages\":\"63\"},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2020-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s43019-020-00075-y\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Knee Surgery & Related Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s43019-020-00075-y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery & Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43019-020-00075-y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 12

摘要

背景:全膝关节置换术(TKA)的术前放射照相模板已被证明是不准确的。患者人口统计数据,如性别、身高、体重、年龄和种族,可能更能预测TKA中植入部件的大小。材料和方法:设计了一个多元线性回归模型,利用201例连续接受指数TKA的患者的人口统计学数据预测植入股骨和胫骨假体的大小。传统的二维放射学模板与基于人口统计学的回归预测在181例连续接受指数TKA的患者中准确预测术中植入物大小的能力进行了比较。外科医生对任何预测都一无所知。结果:患者的性别、身高、体重、年龄和种族/种族可预测植入TKA组件的大小。与放射学模板尺寸相比,回归模型更准确地预测股骨和胫骨植入物的尺寸(P = 0.04)。结论:基于患者特定的人口统计学数据,建立了基于人口统计学的回归模型来预测股骨和胫骨TKA植入物的尺寸。在前瞻性患者系列中,回归模型比放射学模板更准确和精确地预测植入部件的尺寸。证据级别:前瞻性队列,II级。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Demographic data is more predictive of component size than digital radiographic templating in total knee arthroplasty.

Background: Preoperative radiographic templating for total knee arthroplasty (TKA) has been shown to be inaccurate. Patient demographic data, such as gender, height, weight, age, and race, may be more predictive of implanted component size in TKA.

Materials and methods: A multivariate linear regression model was designed to predict implanted femoral and tibial component size using demographic data along a consecutive series of 201 patients undergoing index TKA. Traditional, two-dimensional, radiographic templating was compared to demographic-based regression predictions on a prospective 181 consecutive patients undergoing index TKA in their ability to accurately predict intraoperative implanted sizes. Surgeons were blinded of any predictions.

Results: Patient gender, height, weight, age, and ethnicity/race were predictive of implanted TKA component size. The regression model more accurately predicted implanted component size compared to radiographically templated sizes for both the femoral (P = 0.04) and tibial (P < 0.01) components. The regression model exactly predicted femoral and tibial component sizes in 43.7 and 43.7% of cases, was within one size 90.1 and 95.6% of the time, and was within two sizes in every case. Radiographic templating exactly predicted 35.4 and 36.5% of cases, was within one size 86.2 and 85.1% of the time, and varied up to four sizes for both the femoral and tibial components. The regression model averaged within 0.66 and 0.61 sizes, versus 0.81 and 0.81 sizes for radiographic templating for femoral and tibial components.

Conclusions: A demographic-based regression model was created based on patient-specific demographic data to predict femoral and tibial TKA component sizes. In a prospective patient series, the regression model more accurately and precisely predicted implanted component sizes compared to radiographic templating.

Level of evidence: Prospective cohort, level II.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
0.00%
发文量
0
期刊最新文献
Analysis of radiographic factors affecting the significant differences in knee alignment between hip-to-talus and hip-to-calcaneus radiographs after opening-wedge high tibial osteotomy Ramp lesion in anterior cruciate ligament injury: a review of the anatomy, biomechanics, epidemiology, and diagnosis. Total knee arthroplasty in dialysis patients: a national in-patient sample-based study of perioperative complications. Does body mass index influence improvement in patient reported outcomes following total knee arthroplasty? A retrospective analysis of 3918 cases. Home ownership, full-time employment, and other markers of higher socioeconomic status are predictive of shorter time to initial evaluation, shorter time to surgery, and superior postoperative outcomes among lateral patellar instability patients undergoing medial patellofemoral ligament reconstruction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1