Elena Alberti, Luca Stucchi, Valeria Pesce, Giovanni Stancari, Elisabetta Ferro, Francesco Ferrucci, Enrica Zucca
{"title":"评估基于智能手机的马匹心电图设备在野外和医院条件下的准确性。","authors":"Elena Alberti, Luca Stucchi, Valeria Pesce, Giovanni Stancari, Elisabetta Ferro, Francesco Ferrucci, Enrica Zucca","doi":"10.1136/vetreco-2020-000441","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions.</p><p><strong>Methods: </strong>This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrhythmias, presence/duration of artefacts, electrocardiographic waves and interval parameters by a blinded clinician. Statistical analysis evaluated the agreement between stECG and sECG and the differences in the prevalence of artefact in field and hospital conditions.</p><p><strong>Results: </strong>Nineteen (hospital) and 40 (field) paired ECGs were analysed. Agreement between stECG and sECG was found for heart rate and rhythm, evaluation of atrioventricular block and premature complexes, P wave and PQ interval duration, and QRS complex duration and polarity. No differences were found between artefacts recorded in hospital and in field conditions.</p><p><strong>Conclusion: </strong>sECG is a feasible tool for evaluation of rhythm in horses and is as accurate in field as in ambulatory conditions.</p>","PeriodicalId":23565,"journal":{"name":"Veterinary Record Open","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2020-12-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/15/9f/vetreco-2020-000441.PMC7754639.pdf","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a smartphone-based electrocardiogram device accuracy in field and in hospital conditions in horses.\",\"authors\":\"Elena Alberti, Luca Stucchi, Valeria Pesce, Giovanni Stancari, Elisabetta Ferro, Francesco Ferrucci, Enrica Zucca\",\"doi\":\"10.1136/vetreco-2020-000441\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions.</p><p><strong>Methods: </strong>This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrhythmias, presence/duration of artefacts, electrocardiographic waves and interval parameters by a blinded clinician. Statistical analysis evaluated the agreement between stECG and sECG and the differences in the prevalence of artefact in field and hospital conditions.</p><p><strong>Results: </strong>Nineteen (hospital) and 40 (field) paired ECGs were analysed. Agreement between stECG and sECG was found for heart rate and rhythm, evaluation of atrioventricular block and premature complexes, P wave and PQ interval duration, and QRS complex duration and polarity. No differences were found between artefacts recorded in hospital and in field conditions.</p><p><strong>Conclusion: </strong>sECG is a feasible tool for evaluation of rhythm in horses and is as accurate in field as in ambulatory conditions.</p>\",\"PeriodicalId\":23565,\"journal\":{\"name\":\"Veterinary Record Open\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2020-12-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/15/9f/vetreco-2020-000441.PMC7754639.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Veterinary Record Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1136/vetreco-2020-000441\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Record Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/vetreco-2020-000441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Evaluation of a smartphone-based electrocardiogram device accuracy in field and in hospital conditions in horses.
Background: Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions.
Methods: This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrhythmias, presence/duration of artefacts, electrocardiographic waves and interval parameters by a blinded clinician. Statistical analysis evaluated the agreement between stECG and sECG and the differences in the prevalence of artefact in field and hospital conditions.
Results: Nineteen (hospital) and 40 (field) paired ECGs were analysed. Agreement between stECG and sECG was found for heart rate and rhythm, evaluation of atrioventricular block and premature complexes, P wave and PQ interval duration, and QRS complex duration and polarity. No differences were found between artefacts recorded in hospital and in field conditions.
Conclusion: sECG is a feasible tool for evaluation of rhythm in horses and is as accurate in field as in ambulatory conditions.
期刊介绍:
Veterinary Record Open is a journal dedicated to publishing specialist veterinary research across a range of topic areas including those of a more niche and specialist nature to that considered in the weekly Vet Record. Research from all disciplines of veterinary interest will be considered. It is an Open Access journal of the British Veterinary Association.