化学活化恢复性玻璃离子聚合物水泥动态凝固过程早期阶段的研究。

Fernanda M Tsuzuki, Renata C Pascotto, Luis C Malacarne, Antonio C Bento, Antonio Medina Neto, Lidiane Vizioli de Castro-Hoshino, Monique Souza, John W Nicholson, Mauro L Baesso
{"title":"化学活化恢复性玻璃离子聚合物水泥动态凝固过程早期阶段的研究。","authors":"Fernanda M Tsuzuki,&nbsp;Renata C Pascotto,&nbsp;Luis C Malacarne,&nbsp;Antonio C Bento,&nbsp;Antonio Medina Neto,&nbsp;Lidiane Vizioli de Castro-Hoshino,&nbsp;Monique Souza,&nbsp;John W Nicholson,&nbsp;Mauro L Baesso","doi":"10.1080/26415275.2021.1898964","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the early stages of the setting process of chemically activated restorative glass-ionomer cements (GICs).</p><p><strong>Material and methods: </strong>Five GICs were evaluated (<i>n</i> = 5): Equia Forte (GC), Equia Forte HT (GC), Ketac Universal (3M ESPE), Maxxion R (FGM) and Riva Self Cure (SDI) by Thermography, Fourier Transform Infrared Attenuated Total Reflectance Spectroscopy (FTIR-ATR) and Gillmore needle indentation mechanical testing. The FTIR-ATR spectra showed the formation of metal carboxylates within the cements and enabled the stabilization time (ST) to be determined and the thermographic camera measured the temperature field images in the sample. Data were statistically analyzed by ANOVA and Tukey-Kramer (<i>α</i> = 5%).</p><p><strong>Results: </strong>The Gillmore needle test showed that the order of hardening was opposite to the order of ST values determined by FTIR. The results with the thermographic camera showed two stages of temperature variation, which coincided with the evolution of specific infrared bands. The exception was Maxxion R, which showed only a single step change in temperature.</p><p><strong>Conclusion: </strong>The early stages of the GIC setting reaction show temperature changes, both endothermic and exothermic, at specific times, confirming the occurrence of individual chemical reactions. The early setting involves reactions other than carboxylate formation.<b>Significance</b>: This study gives further detail of the early stages of the setting of GICs, and past research regarding the setting reaction of GIC.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/26415275.2021.1898964","citationCount":"4","resultStr":"{\"title\":\"Studies of the early stages of the dynamic setting process of chemically activated restorative glass-ionomer cements.\",\"authors\":\"Fernanda M Tsuzuki,&nbsp;Renata C Pascotto,&nbsp;Luis C Malacarne,&nbsp;Antonio C Bento,&nbsp;Antonio Medina Neto,&nbsp;Lidiane Vizioli de Castro-Hoshino,&nbsp;Monique Souza,&nbsp;John W Nicholson,&nbsp;Mauro L Baesso\",\"doi\":\"10.1080/26415275.2021.1898964\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the early stages of the setting process of chemically activated restorative glass-ionomer cements (GICs).</p><p><strong>Material and methods: </strong>Five GICs were evaluated (<i>n</i> = 5): Equia Forte (GC), Equia Forte HT (GC), Ketac Universal (3M ESPE), Maxxion R (FGM) and Riva Self Cure (SDI) by Thermography, Fourier Transform Infrared Attenuated Total Reflectance Spectroscopy (FTIR-ATR) and Gillmore needle indentation mechanical testing. The FTIR-ATR spectra showed the formation of metal carboxylates within the cements and enabled the stabilization time (ST) to be determined and the thermographic camera measured the temperature field images in the sample. Data were statistically analyzed by ANOVA and Tukey-Kramer (<i>α</i> = 5%).</p><p><strong>Results: </strong>The Gillmore needle test showed that the order of hardening was opposite to the order of ST values determined by FTIR. The results with the thermographic camera showed two stages of temperature variation, which coincided with the evolution of specific infrared bands. The exception was Maxxion R, which showed only a single step change in temperature.</p><p><strong>Conclusion: </strong>The early stages of the GIC setting reaction show temperature changes, both endothermic and exothermic, at specific times, confirming the occurrence of individual chemical reactions. The early setting involves reactions other than carboxylate formation.<b>Significance</b>: This study gives further detail of the early stages of the setting of GICs, and past research regarding the setting reaction of GIC.</p>\",\"PeriodicalId\":72378,\"journal\":{\"name\":\"Biomaterial investigations in dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/26415275.2021.1898964\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomaterial investigations in dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/26415275.2021.1898964\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/26415275.2021.1898964","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

目的:评价化学活化修复性玻璃离子水门栓(GICs)的早期固位过程。材料和方法:采用热像仪、傅里叶变换红外衰减全反射光谱(FTIR-ATR)和Gillmore针刺压痕力学测试对Equia Forte (GC)、Equia Forte HT (GC)、Ketac Universal (3M ESPE)、Maxxion R (FGM)和Riva Self Cure (SDI) 5种gic (n = 5)进行评价。FTIR-ATR光谱显示了水泥中金属羧酸盐的形成,并确定了稳定时间(ST),热像仪测量了样品中的温度场图像。数据采用方差分析和Tukey-Kramer (α = 5%)进行统计学分析。结果:Gillmore针刺试验显示硬化顺序与FTIR测定的ST值顺序相反。热像仪的结果显示了两个阶段的温度变化,这与特定红外波段的演变相吻合。唯一的例外是Maxxion R,它只显示了温度的单阶变化。结论:GIC固化反应的早期阶段在特定时间表现出吸热和放热的温度变化,证实了个体化学反应的发生。早期形成包括羧酸盐形成以外的其他反应。意义:本研究进一步详细介绍了GIC的早期设置,以及过去关于GIC设置反应的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Studies of the early stages of the dynamic setting process of chemically activated restorative glass-ionomer cements.

Objective: To evaluate the early stages of the setting process of chemically activated restorative glass-ionomer cements (GICs).

Material and methods: Five GICs were evaluated (n = 5): Equia Forte (GC), Equia Forte HT (GC), Ketac Universal (3M ESPE), Maxxion R (FGM) and Riva Self Cure (SDI) by Thermography, Fourier Transform Infrared Attenuated Total Reflectance Spectroscopy (FTIR-ATR) and Gillmore needle indentation mechanical testing. The FTIR-ATR spectra showed the formation of metal carboxylates within the cements and enabled the stabilization time (ST) to be determined and the thermographic camera measured the temperature field images in the sample. Data were statistically analyzed by ANOVA and Tukey-Kramer (α = 5%).

Results: The Gillmore needle test showed that the order of hardening was opposite to the order of ST values determined by FTIR. The results with the thermographic camera showed two stages of temperature variation, which coincided with the evolution of specific infrared bands. The exception was Maxxion R, which showed only a single step change in temperature.

Conclusion: The early stages of the GIC setting reaction show temperature changes, both endothermic and exothermic, at specific times, confirming the occurrence of individual chemical reactions. The early setting involves reactions other than carboxylate formation.Significance: This study gives further detail of the early stages of the setting of GICs, and past research regarding the setting reaction of GIC.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
期刊最新文献
Recipient of Biomaterial Investigations in Dentistry's Young Author Award 2023. Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction. The sealing ability of different endodontic biomaterials as an intra-orifice barrier: evaluation with high-performance liquid chromatography. An in vitro study on the influence of laser-activated irrigation on infiltration and leakage of a dual curing-resin cement as an endodontic sealer Accumulation and removal of Streptococcus mutans biofilm on enamel and root surfaces in vitro
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1