识别阻塞性睡眠呼吸暂停高危患者的新型临床筛查方法。

IF 2 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Cranio-The Journal of Craniomandibular & Sleep Practice Pub Date : 2024-03-01 Epub Date: 2021-05-30 DOI:10.1080/08869634.2021.1933308
Mehmet Murat Günay, Güleser Saylam, İbrahim Hikmet Fırat, İlker Akyıldız, Ömer Bayır, Murad Mutlu, Mehmet Hakan Korkmaz
{"title":"识别阻塞性睡眠呼吸暂停高危患者的新型临床筛查方法。","authors":"Mehmet Murat Günay, Güleser Saylam, İbrahim Hikmet Fırat, İlker Akyıldız, Ömer Bayır, Murad Mutlu, Mehmet Hakan Korkmaz","doi":"10.1080/08869634.2021.1933308","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate whether the distance between the two retromolar trigones (RMTs) with the distance between the two posterior plicas (PPs) affects obstructive sleep apnea syndrome (OSAS) and to determine a physical examination method that can be used in the selection of patients to be referred to polysomnography (PSG).</p><p><strong>Methods: </strong>The study included 86 OSAS patients and 29 healthy controls. RMTs and PPs were measured using a caliper-like device. The values obtained from these measurements were evaluated in both groups.</p><p><strong>Results: </strong>The PPs were narrower, and the RMTs-PPs, RMTs-PPs/RMTs, and RMTs/PPs values were greater in the OSAS group (<i>p</i> < .05) compared to the control group. The cut-off values were 0.612 for RMTs-PPs/RMTs and 2.589 for RMTs/PPs. The specificity of these values for OSAS was 97%, and sensitivity was 57% and 58%, respectively.</p><p><strong>Conclusion: </strong>The presented method may play a role in preventing unnecessary PSG among patients with suspected OSAS.</p>","PeriodicalId":56318,"journal":{"name":"Cranio-The Journal of Craniomandibular & Sleep Practice","volume":" ","pages":"190-198"},"PeriodicalIF":2.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Novel clinical screening method to identify patients at risk of obstructive sleep apnea.\",\"authors\":\"Mehmet Murat Günay, Güleser Saylam, İbrahim Hikmet Fırat, İlker Akyıldız, Ömer Bayır, Murad Mutlu, Mehmet Hakan Korkmaz\",\"doi\":\"10.1080/08869634.2021.1933308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate whether the distance between the two retromolar trigones (RMTs) with the distance between the two posterior plicas (PPs) affects obstructive sleep apnea syndrome (OSAS) and to determine a physical examination method that can be used in the selection of patients to be referred to polysomnography (PSG).</p><p><strong>Methods: </strong>The study included 86 OSAS patients and 29 healthy controls. RMTs and PPs were measured using a caliper-like device. The values obtained from these measurements were evaluated in both groups.</p><p><strong>Results: </strong>The PPs were narrower, and the RMTs-PPs, RMTs-PPs/RMTs, and RMTs/PPs values were greater in the OSAS group (<i>p</i> < .05) compared to the control group. The cut-off values were 0.612 for RMTs-PPs/RMTs and 2.589 for RMTs/PPs. The specificity of these values for OSAS was 97%, and sensitivity was 57% and 58%, respectively.</p><p><strong>Conclusion: </strong>The presented method may play a role in preventing unnecessary PSG among patients with suspected OSAS.</p>\",\"PeriodicalId\":56318,\"journal\":{\"name\":\"Cranio-The Journal of Craniomandibular & Sleep Practice\",\"volume\":\" \",\"pages\":\"190-198\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cranio-The Journal of Craniomandibular & Sleep Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08869634.2021.1933308\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/5/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cranio-The Journal of Craniomandibular & Sleep Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08869634.2021.1933308","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/5/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的研究两个后枕骨三叉神经节(RMT)之间的距离与两个后枕骨三叉神经节(PP)之间的距离是否会影响阻塞性睡眠呼吸暂停综合征(OSAS),并确定一种体格检查方法,用于选择转诊至多导睡眠图(PSG)检查的患者:研究对象包括 86 名 OSAS 患者和 29 名健康对照者。使用一种类似卡尺的设备测量 RMT 和 PP。对两组患者的测量值进行评估:结果:OSAS 组的 PPs 较窄,RMTs-PPs、RMTs-PPs/RMTs 和 RMTs/PPs 值较大(p 结论:该方法可能对 OSAS 起作用:该方法可在防止疑似 OSAS 患者进行不必要的 PSG 方面发挥作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Novel clinical screening method to identify patients at risk of obstructive sleep apnea.

Objective: To investigate whether the distance between the two retromolar trigones (RMTs) with the distance between the two posterior plicas (PPs) affects obstructive sleep apnea syndrome (OSAS) and to determine a physical examination method that can be used in the selection of patients to be referred to polysomnography (PSG).

Methods: The study included 86 OSAS patients and 29 healthy controls. RMTs and PPs were measured using a caliper-like device. The values obtained from these measurements were evaluated in both groups.

Results: The PPs were narrower, and the RMTs-PPs, RMTs-PPs/RMTs, and RMTs/PPs values were greater in the OSAS group (p < .05) compared to the control group. The cut-off values were 0.612 for RMTs-PPs/RMTs and 2.589 for RMTs/PPs. The specificity of these values for OSAS was 97%, and sensitivity was 57% and 58%, respectively.

Conclusion: The presented method may play a role in preventing unnecessary PSG among patients with suspected OSAS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Cranio-The Journal of Craniomandibular & Sleep Practice
Cranio-The Journal of Craniomandibular & Sleep Practice DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.50
自引率
12.50%
发文量
92
审稿时长
>12 weeks
期刊介绍: CRANIO: The Journal of Craniomandibular & Sleep Practice is the oldest and largest journal in the world devoted to temporomandibular disorders, and now also includes articles on all aspects of sleep medicine. The Journal is multidisciplinary in its scope, with editorial board members from all areas of medicine and dentistry, including general dentists, oral surgeons, orthopaedists, radiologists, chiropractors, professors and behavioural scientists, physical therapists, acupuncturists, osteopathic and ear, nose and throat physicians. CRANIO publishes commendable works from outstanding researchers and clinicians in their respective fields. The multidisciplinary format allows individuals practicing with a TMD emphasis to stay abreast of related disciplines, as each issue presents multiple topics from overlapping areas of interest. CRANIO''s current readership (thousands) is comprised primarily of dentists; however, many physicians, physical therapists, chiropractors, osteopathic physicians and other related specialists subscribe and contribute to the Journal.
期刊最新文献
Is there an association between parenting styles, personality traits, and parent-reported sleep bruxism in Brazilian children? Sleep bruxism and GERD correlation in a general population convenience sample. Prevalence of temporomandibular disorders (TMD) and their association with sociodemographic factors and depression/anxiety symptoms in Northern Finland Birth Cohort 1986. Prevalence of serum vitamin D and B12, Ca, P, Mg levels and rheumatoid factor status in the patients with bilateral TMJ-OA and their correlations with clinical and radiological findings. The role of a dental healthcare provider.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1