{"title":"自锁钉和环向钢丝治疗粉碎性髌骨骨折实现癫痫式坐位的手术治疗。","authors":"Kazuha Kizaki, Soshi Uchida, Noboru Funakoshi, Daisuke Mori, Ryosuke Nakai, Fumiharu Yamashita","doi":"10.1055/s-0041-1730379","DOIUrl":null,"url":null,"abstract":"<p><p>Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion.</p>","PeriodicalId":37852,"journal":{"name":"Joints","volume":"7 4","pages":"218-221"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/s-0041-1730379","citationCount":"1","resultStr":"{\"title\":\"Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting.\",\"authors\":\"Kazuha Kizaki, Soshi Uchida, Noboru Funakoshi, Daisuke Mori, Ryosuke Nakai, Fumiharu Yamashita\",\"doi\":\"10.1055/s-0041-1730379\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion.</p>\",\"PeriodicalId\":37852,\"journal\":{\"name\":\"Joints\",\"volume\":\"7 4\",\"pages\":\"218-221\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1055/s-0041-1730379\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Joints\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0041-1730379\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2019/12/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Joints","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0041-1730379","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/12/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1
摘要
髌骨粉碎性骨折的手术固定在技术上具有挑战性。尽管张力带钢丝或螺钉固定是最常见的手术方法,但这些手术技术对于外侧分散碎片有很大的局限性。我们展示了两例粉碎性髌骨骨折,采用自锁针和周向钢丝进行手术固定,证实了刚性固定实现了膝关节深度屈曲。经中线纵皮切口后,沿径向插入2.0 mm不锈钢钉(AiMedic MMT, Tokyo, Japan)穿透每个碎片,1.2 mm不锈钢丝沿周环自锁在钉孔内,满足刚性固定。术后需要对活动范围和负重进行任何限制,术后3至6个月的护理可实现癫痫样坐姿,膝关节深屈。
Surgical Management with Self-Locking Pins and Circumferential Wiring for Treating Comminuted Patella Fractures Achieved Seiza-Style Sitting.
Surgical fixation of comminuted patella fractures is technically challenging. Despite the fact that tension band wiring or screw fixation are the most common surgical procedures, these surgical techniques have crucial limitations for laterally scattered fragments. We demonstrate two cases with comminuted patella fractures undergoing surgical fixation with self-locking pin and circumferential wiring, confirming the rigid fixation achieving deep knee flexion. After midline longitudinal skin incision, 2.0 mm stainless pins (AiMedic MMT, Tokyo, Japan) were inserted radially to penetrate each fragment and 1.2 mm stainless wire was circumferentially looped and self-locked in the holes on the pins, which satisfied rigid fixation. Any restrictions in range of motion and weight bearing were required postoperatively and 3- to 6-month postoperative cares achieved seiza-style sitting with deep knee flexion.
期刊介绍:
Joints is the official publication of SIGASCOT (Italian Society of the Knee, Arthroscopy, Sports Traumatology, Cartilage and Orthopaedic Technology). As an Open Acccess journal, it publishes papers on clinical and basic research, review articles, technical notes, case reports, and editorials about the latest developments in knee surgery, arthroscopy, sports traumatology, cartilage, orthopaedic technology, upper limb, and related rehabilitation. Letters to the Editor and comments on the journal''s content are always welcome.