Stephen Siemonsma, Stanley Kruger, Arvind Balachandrasekaran, Merry Mani, Mathews Jacob
{"title":"采用结构化低秩矩阵补全技术进行场非均匀性补偿的多回波恢复。","authors":"Stephen Siemonsma, Stanley Kruger, Arvind Balachandrasekaran, Merry Mani, Mathews Jacob","doi":"10.1109/isbi45749.2020.9098418","DOIUrl":null,"url":null,"abstract":"<p><p>Echo-planar imaging (EPI), which is the main workhorse of functional MRI, suffers from field inhomogeneity-induced geometric distortions. The amount of distortion is proportional to the readout duration, which restricts the maximum achievable spatial resolution. The spatially varying nature of the <math> <mrow><msubsup><mi>T</mi> <mn>2</mn> <mo>*</mo></msubsup> </mrow> </math> decay makes it challenging for EPI schemes with a single echo time to obtain good sensitivity to functional activations in different brain regions. Despite the use of parallel MRI and multislice acceleration, the number of different echo times that can be acquired in a reasonable TR is limited. The main focus of this work is to introduce a rosette-based acquisition scheme and a structured low-rank reconstruction algorithm to overcome the above challenges. The proposed scheme exploits the exponential structure of the time series to recover distortion-free images from several echoes simultaneously.</p>","PeriodicalId":74566,"journal":{"name":"Proceedings. IEEE International Symposium on Biomedical Imaging","volume":" ","pages":"1074-1077"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/isbi45749.2020.9098418","citationCount":"0","resultStr":"{\"title\":\"MULTI-ECHO RECOVERY WITH FIELD INHOMOGENEITY COMPENSATION USING STRUCTURED LOW-RANK MATRIX COMPLETION.\",\"authors\":\"Stephen Siemonsma, Stanley Kruger, Arvind Balachandrasekaran, Merry Mani, Mathews Jacob\",\"doi\":\"10.1109/isbi45749.2020.9098418\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Echo-planar imaging (EPI), which is the main workhorse of functional MRI, suffers from field inhomogeneity-induced geometric distortions. The amount of distortion is proportional to the readout duration, which restricts the maximum achievable spatial resolution. The spatially varying nature of the <math> <mrow><msubsup><mi>T</mi> <mn>2</mn> <mo>*</mo></msubsup> </mrow> </math> decay makes it challenging for EPI schemes with a single echo time to obtain good sensitivity to functional activations in different brain regions. Despite the use of parallel MRI and multislice acceleration, the number of different echo times that can be acquired in a reasonable TR is limited. The main focus of this work is to introduce a rosette-based acquisition scheme and a structured low-rank reconstruction algorithm to overcome the above challenges. The proposed scheme exploits the exponential structure of the time series to recover distortion-free images from several echoes simultaneously.</p>\",\"PeriodicalId\":74566,\"journal\":{\"name\":\"Proceedings. IEEE International Symposium on Biomedical Imaging\",\"volume\":\" \",\"pages\":\"1074-1077\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1109/isbi45749.2020.9098418\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings. IEEE International Symposium on Biomedical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/isbi45749.2020.9098418\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2020/5/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. IEEE International Symposium on Biomedical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/isbi45749.2020.9098418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/5/22 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
MULTI-ECHO RECOVERY WITH FIELD INHOMOGENEITY COMPENSATION USING STRUCTURED LOW-RANK MATRIX COMPLETION.
Echo-planar imaging (EPI), which is the main workhorse of functional MRI, suffers from field inhomogeneity-induced geometric distortions. The amount of distortion is proportional to the readout duration, which restricts the maximum achievable spatial resolution. The spatially varying nature of the decay makes it challenging for EPI schemes with a single echo time to obtain good sensitivity to functional activations in different brain regions. Despite the use of parallel MRI and multislice acceleration, the number of different echo times that can be acquired in a reasonable TR is limited. The main focus of this work is to introduce a rosette-based acquisition scheme and a structured low-rank reconstruction algorithm to overcome the above challenges. The proposed scheme exploits the exponential structure of the time series to recover distortion-free images from several echoes simultaneously.