由新手操作的动态种植导航手术的准确性。

IF 1.8 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Computerized Dentistry Pub Date : 2022-11-25 DOI:10.3290/j.ijcd.b2588207
Jordi Marques-Guasch, Rafel Rodriguez-Bauzá, Marta Satorres-Nieto, Wang Hom-Lay, Federico Hernández-Alfaro, Jordi Gargallo-Albiol
{"title":"由新手操作的动态种植导航手术的准确性。","authors":"Jordi Marques-Guasch,&nbsp;Rafel Rodriguez-Bauzá,&nbsp;Marta Satorres-Nieto,&nbsp;Wang Hom-Lay,&nbsp;Federico Hernández-Alfaro,&nbsp;Jordi Gargallo-Albiol","doi":"10.3290/j.ijcd.b2588207","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The main objective was to evaluate the accuracy of dynamic navigation-guided surgery (DNGS) for implant positioning performed by a novice operator. The secondary objectives were to analyze the operator's learning curve and identify possible complications deriving from the technique.</p><p><strong>Materials and methods: </strong>Twenty-five implants were placed in eight partially edentulous human heads. Preoperative CBCT scans were imported to planning software to determine the implant positions. Implants were placed using a dynamic navigation system. Postoperative CBCTs were superimposed onto the implant planning images. Discrepancies between the virtually planned implant positions and the postoperative positions were evaluated by measuring horizontal platform deviation, apex deviation, apicocoronal (vertical) deviation, and angular deviation.</p><p><strong>Results: </strong>Mean platform, apex, vertical, and angle deviations were 1.55 ± 0.81 mm, 2.45 ± 0.84 mm, 1.59 ± 0.70 mm, and 5.56 ± 4.03 degrees, respectively. No significant differences were found between the maxilla and mandible or between anterior and posterior sites. A flat learning curve was observed, with the exception of the implant platform, where a tendency toward improvement in accuracy was observed between the 8th and the 17th implant placed. No complications were reported.</p><p><strong>Conclusions: </strong>Based on the results of a study performed by a novice operator on a cadaveric model, DNGS allows accurate implant placement within a 2-mm safety margin in terms of implant platform and vertical positions, and a 3-mm margin in apical vicinities. The technique requires practice to learn the required eye-hand coordination. (Int J Comput Dent 2022;25(4):377-0; doi: 10.3290/j.ijcd.b2588207).</p>","PeriodicalId":48666,"journal":{"name":"International Journal of Computerized Dentistry","volume":"25 4","pages":"377-385"},"PeriodicalIF":1.8000,"publicationDate":"2022-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Accuracy of dynamic implant navigation surgery performed by a novice operator.\",\"authors\":\"Jordi Marques-Guasch,&nbsp;Rafel Rodriguez-Bauzá,&nbsp;Marta Satorres-Nieto,&nbsp;Wang Hom-Lay,&nbsp;Federico Hernández-Alfaro,&nbsp;Jordi Gargallo-Albiol\",\"doi\":\"10.3290/j.ijcd.b2588207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The main objective was to evaluate the accuracy of dynamic navigation-guided surgery (DNGS) for implant positioning performed by a novice operator. The secondary objectives were to analyze the operator's learning curve and identify possible complications deriving from the technique.</p><p><strong>Materials and methods: </strong>Twenty-five implants were placed in eight partially edentulous human heads. Preoperative CBCT scans were imported to planning software to determine the implant positions. Implants were placed using a dynamic navigation system. Postoperative CBCTs were superimposed onto the implant planning images. Discrepancies between the virtually planned implant positions and the postoperative positions were evaluated by measuring horizontal platform deviation, apex deviation, apicocoronal (vertical) deviation, and angular deviation.</p><p><strong>Results: </strong>Mean platform, apex, vertical, and angle deviations were 1.55 ± 0.81 mm, 2.45 ± 0.84 mm, 1.59 ± 0.70 mm, and 5.56 ± 4.03 degrees, respectively. No significant differences were found between the maxilla and mandible or between anterior and posterior sites. A flat learning curve was observed, with the exception of the implant platform, where a tendency toward improvement in accuracy was observed between the 8th and the 17th implant placed. No complications were reported.</p><p><strong>Conclusions: </strong>Based on the results of a study performed by a novice operator on a cadaveric model, DNGS allows accurate implant placement within a 2-mm safety margin in terms of implant platform and vertical positions, and a 3-mm margin in apical vicinities. The technique requires practice to learn the required eye-hand coordination. (Int J Comput Dent 2022;25(4):377-0; doi: 10.3290/j.ijcd.b2588207).</p>\",\"PeriodicalId\":48666,\"journal\":{\"name\":\"International Journal of Computerized Dentistry\",\"volume\":\"25 4\",\"pages\":\"377-385\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2022-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Computerized Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.ijcd.b2588207\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computerized Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.ijcd.b2588207","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 2

摘要

目的:主要目的是评估由新手操作的动态导航引导手术(DNGS)用于种植体定位的准确性。次要目标是分析操作人员的学习曲线,并确定该技术可能产生的并发症。材料和方法:25个植入物放置在8个部分无牙的人类头部。术前CBCT扫描导入规划软件,确定种植体位置。植入物使用动态导航系统放置。术后cbct叠加在种植体计划图像上。通过测量水平平台偏差、尖端偏差、冠状(垂直)偏差和角偏差来评估虚拟计划种植体位置与术后位置之间的差异。结果:平均平台、顶点、垂直和角度偏差分别为1.55±0.81 mm、2.45±0.84 mm、1.59±0.70 mm和5.56±4.03度。上颌与下颌骨之间、前后部位之间无明显差异。除了种植体平台外,观察到一个平坦的学习曲线,在放置的第8个和第17个种植体之间,观察到准确性有改善的趋势。无并发症报道。结论:根据一名新手在尸体模型上进行的研究结果,DNGS可以在种植体平台和垂直位置的2毫米安全范围内精确放置种植体,在根尖附近的3毫米安全范围内。这项技术需要练习来学习所需的手眼协调能力。[J] .计算机学报;2009;25(4):377-0;doi: 10.3290 / j.ijcd.b2588207)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy of dynamic implant navigation surgery performed by a novice operator.

Aim: The main objective was to evaluate the accuracy of dynamic navigation-guided surgery (DNGS) for implant positioning performed by a novice operator. The secondary objectives were to analyze the operator's learning curve and identify possible complications deriving from the technique.

Materials and methods: Twenty-five implants were placed in eight partially edentulous human heads. Preoperative CBCT scans were imported to planning software to determine the implant positions. Implants were placed using a dynamic navigation system. Postoperative CBCTs were superimposed onto the implant planning images. Discrepancies between the virtually planned implant positions and the postoperative positions were evaluated by measuring horizontal platform deviation, apex deviation, apicocoronal (vertical) deviation, and angular deviation.

Results: Mean platform, apex, vertical, and angle deviations were 1.55 ± 0.81 mm, 2.45 ± 0.84 mm, 1.59 ± 0.70 mm, and 5.56 ± 4.03 degrees, respectively. No significant differences were found between the maxilla and mandible or between anterior and posterior sites. A flat learning curve was observed, with the exception of the implant platform, where a tendency toward improvement in accuracy was observed between the 8th and the 17th implant placed. No complications were reported.

Conclusions: Based on the results of a study performed by a novice operator on a cadaveric model, DNGS allows accurate implant placement within a 2-mm safety margin in terms of implant platform and vertical positions, and a 3-mm margin in apical vicinities. The technique requires practice to learn the required eye-hand coordination. (Int J Comput Dent 2022;25(4):377-0; doi: 10.3290/j.ijcd.b2588207).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Computerized Dentistry
International Journal of Computerized Dentistry Dentistry-Dentistry (miscellaneous)
CiteScore
2.90
自引率
0.00%
发文量
49
期刊介绍: This journal explores the myriad innovations in the emerging field of computerized dentistry and how to integrate them into clinical practice. The bulk of the journal is devoted to the science of computer-assisted dentistry, with research articles and clinical reports on all aspects of computer-based diagnostic and therapeutic applications, with special emphasis placed on CAD/CAM and image-processing systems. Articles also address the use of computer-based communication to support patient care, assess the quality of care, and enhance clinical decision making. The journal is presented in a bilingual format, with each issue offering three types of articles: science-based, application-based, and national society reports.
期刊最新文献
Impact of Digital Manufacturing Methods on the Accuracy of Ceramic Crowns. Accuracy of imaging software usable in clinical settings for 3D rendering of tooth structures. Digital workflow in oral splint manufacturing. Deep learning for diagnostic charting on pediatric panoramic radiographs. Preformed customized healing abutments in a biologically oriented preparation technique procedure: a 3-year retrospective case-control study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1