止血剂对牙本质的污染--在使用自酸通用粘合剂之前,EDTA 是否是一种有价值的去污剂?

IF 2.5 3区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Adhesive Dentistry Pub Date : 2022-09-18 DOI:10.3290/j.jad.b3441525
Carolin Anne Mempel, Silke Jacker-Guhr, Anne-Katrin Lührs
{"title":"止血剂对牙本质的污染--在使用自酸通用粘合剂之前,EDTA 是否是一种有价值的去污剂?","authors":"Carolin Anne Mempel, Silke Jacker-Guhr, Anne-Katrin Lührs","doi":"10.3290/j.jad.b3441525","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the effects of dentin decontamination procedures with ethylenediaminetetraacetic acid (EDTA) after contamination with two hemostatic agents, ViscoStat (VS) and ViscoStat Clear (VSC), on the microtensile bond strength (μTBS) of two different universal adhesives, before and after thermocycling (TC).</p><p><strong>Materials and methods: </strong>Dentin surfaces of 100 human caries-free molars were either contaminated with one of the hemostatic agents or contaminated and then decontaminated with EDTA before the universal adhesives Scotchbond Universal Adhesive (SBU) or Prime & Bond Active (PBA) were applied in self-etch mode. Composite buildups were made and the teeth were sectioned into sticks (n = 90). Half of them immediately underwent the μTBS test, the other half after aging via TC. The data were statistically analyzed using Welch's ANOVA and the Games-Howell post-hoc test (p < 0.05).</p><p><strong>Results: </strong>Significant differences were observed between the groups (p < 0.001). When the dentin surface was contaminated with VSC, TC significantly reduced the mean bond strength, regardless of the universal adhesive. Decontamination with EDTA showed a significant decrease in bond strength after VS contamination and SBU application. The fracture analysis showed mainly adhesive fractures (78.8%) in all test groups.</p><p><strong>Conclusion: </strong>As EDTA application did not significantly increase the μTBS of either universal adhesive in self-etch mode in-vitro, it cannot be recommended as a decontaminant.</p>","PeriodicalId":55604,"journal":{"name":"Journal of Adhesive Dentistry","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2022-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Contamination of Dentin with Hemostatic Agents - Is EDTA a Valuable Decontaminant before Using a Self-etch Universal Adhesive?\",\"authors\":\"Carolin Anne Mempel, Silke Jacker-Guhr, Anne-Katrin Lührs\",\"doi\":\"10.3290/j.jad.b3441525\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To investigate the effects of dentin decontamination procedures with ethylenediaminetetraacetic acid (EDTA) after contamination with two hemostatic agents, ViscoStat (VS) and ViscoStat Clear (VSC), on the microtensile bond strength (μTBS) of two different universal adhesives, before and after thermocycling (TC).</p><p><strong>Materials and methods: </strong>Dentin surfaces of 100 human caries-free molars were either contaminated with one of the hemostatic agents or contaminated and then decontaminated with EDTA before the universal adhesives Scotchbond Universal Adhesive (SBU) or Prime & Bond Active (PBA) were applied in self-etch mode. Composite buildups were made and the teeth were sectioned into sticks (n = 90). Half of them immediately underwent the μTBS test, the other half after aging via TC. The data were statistically analyzed using Welch's ANOVA and the Games-Howell post-hoc test (p < 0.05).</p><p><strong>Results: </strong>Significant differences were observed between the groups (p < 0.001). When the dentin surface was contaminated with VSC, TC significantly reduced the mean bond strength, regardless of the universal adhesive. Decontamination with EDTA showed a significant decrease in bond strength after VS contamination and SBU application. The fracture analysis showed mainly adhesive fractures (78.8%) in all test groups.</p><p><strong>Conclusion: </strong>As EDTA application did not significantly increase the μTBS of either universal adhesive in self-etch mode in-vitro, it cannot be recommended as a decontaminant.</p>\",\"PeriodicalId\":55604,\"journal\":{\"name\":\"Journal of Adhesive Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2022-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Adhesive Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.b3441525\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Adhesive Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3290/j.jad.b3441525","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究在两种止血剂 ViscoStat (VS) 和 ViscoStat Clear (VSC) 污染牙本质后使用乙二胺四乙酸(EDTA)进行去污处理对两种不同通用粘合剂在热循环(TC)前后的微拉伸粘合强度(μTBS)的影响:在以自酸蚀模式使用通用粘合剂 Scotchbond Universal Adhesive (SBU) 或 Prime & Bond Active (PBA) 之前,先用其中一种止血剂污染或用 EDTA 污染牙本质表面,然后再用 EDTA 去污。制作复合材料并将牙齿切成小块(n = 90)。其中一半立即进行 μTBS 测试,另一半通过 TC 老化后进行测试。采用韦尔奇方差分析和 Games-Howell 事后检验对数据进行统计分析(P < 0.05):结果:各组之间存在显著差异(p < 0.001)。当牙本质表面受到 VSC 污染时,无论使用哪种通用粘合剂,TC 都会显著降低平均粘接强度。使用 EDTA 去污表明,在 VS 污染和使用 SBU 后,粘接强度明显下降。断裂分析表明,在所有测试组中,主要是粘合剂断裂(78.8%):结论:在体外自酸蚀模式下,使用 EDTA 并不能明显提高两种通用粘合剂的 μTBS 值,因此不能推荐使用 EDTA 作为去污剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contamination of Dentin with Hemostatic Agents - Is EDTA a Valuable Decontaminant before Using a Self-etch Universal Adhesive?

Purpose: To investigate the effects of dentin decontamination procedures with ethylenediaminetetraacetic acid (EDTA) after contamination with two hemostatic agents, ViscoStat (VS) and ViscoStat Clear (VSC), on the microtensile bond strength (μTBS) of two different universal adhesives, before and after thermocycling (TC).

Materials and methods: Dentin surfaces of 100 human caries-free molars were either contaminated with one of the hemostatic agents or contaminated and then decontaminated with EDTA before the universal adhesives Scotchbond Universal Adhesive (SBU) or Prime & Bond Active (PBA) were applied in self-etch mode. Composite buildups were made and the teeth were sectioned into sticks (n = 90). Half of them immediately underwent the μTBS test, the other half after aging via TC. The data were statistically analyzed using Welch's ANOVA and the Games-Howell post-hoc test (p < 0.05).

Results: Significant differences were observed between the groups (p < 0.001). When the dentin surface was contaminated with VSC, TC significantly reduced the mean bond strength, regardless of the universal adhesive. Decontamination with EDTA showed a significant decrease in bond strength after VS contamination and SBU application. The fracture analysis showed mainly adhesive fractures (78.8%) in all test groups.

Conclusion: As EDTA application did not significantly increase the μTBS of either universal adhesive in self-etch mode in-vitro, it cannot be recommended as a decontaminant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Adhesive Dentistry
Journal of Adhesive Dentistry 医学-牙科与口腔外科
CiteScore
5.20
自引率
6.10%
发文量
44
审稿时长
6-12 weeks
期刊介绍: New materials and applications for adhesion are profoundly changing the way dentistry is delivered. Bonding techniques, which have long been restricted to the tooth hard tissues, enamel, and dentin, have obvious applications in operative and preventive dentistry, as well as in esthetic and pediatric dentistry, prosthodontics, and orthodontics. The current development of adhesive techniques for soft tissues and slow-releasing agents will expand applications to include periodontics and oral surgery. Scientifically sound, peer-reviewed articles explore the latest innovations in these emerging fields.
期刊最新文献
Preheated Composite as an Alternative for Bonding Feldspathic and Hybrid Ceramics: A Microshear Bond Strength Study. Fourteen-year Clinical Performance of a HEMA-free One-step Self-etch Adhesive in Non-carious Cervical Lesions. Three-year Clinical Performance of a Universal Adhesive in Non-Carious Cervical Lesions. Effects of Surface Treatment and Thermocycling on the Shear Bond Strength of Zirconia-Reinforced Lithium Silicate Ceramic. Effect of Carbodiimide (EDC) on the Bond Strength Longevity of Epoxy Resin-based Endodontic Sealer to Root Dentin: An In-Vitro Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1