Gian Luca Salvagno, Brandon M Henry, Nitto Simone de, Laura Pighi, Giuseppe Lippi
{"title":"常规鼻咽标本中SARS-CoV-2快速抗原检测病毒载量与阳性时间的关系","authors":"Gian Luca Salvagno, Brandon M Henry, Nitto Simone de, Laura Pighi, Giuseppe Lippi","doi":"10.5937/jomb0-35482","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Rapid SARS-CoV-2 antigen tests are potentially useful tools for screening carriers with high viral load. This study was aimed to assess the potential association between viral load and positivization time of a manual SARS-CoV-2 commercial antigen test in routine nasopharyngeal specimens.</p><p><strong>Methods: </strong>In a sample of subjects undergoing routine diagnostic testing, SARS-CoV-2 positivity of nasopharyngeal samples was assayed with both molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) and antigenic (Roche SARS-CoV-2 Rapid Antigen Test) tests. Positivization time of rapid antigen test was correlated and compared with viral load expressed as mean of SARS-CoV2 E/S genes cycle threshold (Ct) values.</p><p><strong>Results: </strong>The study sample consisted of 106 patients (median age 48 years, 55 women) with positive results of rapid SARS-CoV-2 antigen testing. A highly significant Spearman's correlation was found between mean SARSCoV-2 E/S genes Ct values and positivization time of manual antigen test (r= 0.70; p<0.001). The positivization time of rapid SARS-CoV-2 antigen test displayed an area under the curve of 0.82 (95%CI, 0.74-0.89) for predicting nasopharyngeal samples with high viral load (i.e., mean Ct <20). A positivization time cut-off of 32 SEC had 94.9% sensitivity and 58.2% specificity for detecting specimens with high viral load. The overall agreement between mean Ct value <20 and positivization time <32 SEC was 70.8%.</p><p><strong>Conclusions: </strong>Positivization time of rapid SARS-CoV-2 antigen tests may provide easy and rapid information on viral load, thus making this type of manual assay potentially suitable for quick and reliable detection and isolation of supercarriers.</p>","PeriodicalId":16175,"journal":{"name":"Journal of Medical Biochemistry","volume":"41 4","pages":"513-517"},"PeriodicalIF":2.0000,"publicationDate":"2022-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618342/pdf/","citationCount":"4","resultStr":"{\"title\":\"Association between viral load and positivization time of a SARS-CoV-2 rapid antigen test in routine nasopharyngeal specimens.\",\"authors\":\"Gian Luca Salvagno, Brandon M Henry, Nitto Simone de, Laura Pighi, Giuseppe Lippi\",\"doi\":\"10.5937/jomb0-35482\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Rapid SARS-CoV-2 antigen tests are potentially useful tools for screening carriers with high viral load. This study was aimed to assess the potential association between viral load and positivization time of a manual SARS-CoV-2 commercial antigen test in routine nasopharyngeal specimens.</p><p><strong>Methods: </strong>In a sample of subjects undergoing routine diagnostic testing, SARS-CoV-2 positivity of nasopharyngeal samples was assayed with both molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) and antigenic (Roche SARS-CoV-2 Rapid Antigen Test) tests. Positivization time of rapid antigen test was correlated and compared with viral load expressed as mean of SARS-CoV2 E/S genes cycle threshold (Ct) values.</p><p><strong>Results: </strong>The study sample consisted of 106 patients (median age 48 years, 55 women) with positive results of rapid SARS-CoV-2 antigen testing. A highly significant Spearman's correlation was found between mean SARSCoV-2 E/S genes Ct values and positivization time of manual antigen test (r= 0.70; p<0.001). The positivization time of rapid SARS-CoV-2 antigen test displayed an area under the curve of 0.82 (95%CI, 0.74-0.89) for predicting nasopharyngeal samples with high viral load (i.e., mean Ct <20). A positivization time cut-off of 32 SEC had 94.9% sensitivity and 58.2% specificity for detecting specimens with high viral load. The overall agreement between mean Ct value <20 and positivization time <32 SEC was 70.8%.</p><p><strong>Conclusions: </strong>Positivization time of rapid SARS-CoV-2 antigen tests may provide easy and rapid information on viral load, thus making this type of manual assay potentially suitable for quick and reliable detection and isolation of supercarriers.</p>\",\"PeriodicalId\":16175,\"journal\":{\"name\":\"Journal of Medical Biochemistry\",\"volume\":\"41 4\",\"pages\":\"513-517\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2022-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618342/pdf/\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Biochemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5937/jomb0-35482\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5937/jomb0-35482","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
Association between viral load and positivization time of a SARS-CoV-2 rapid antigen test in routine nasopharyngeal specimens.
Background: Rapid SARS-CoV-2 antigen tests are potentially useful tools for screening carriers with high viral load. This study was aimed to assess the potential association between viral load and positivization time of a manual SARS-CoV-2 commercial antigen test in routine nasopharyngeal specimens.
Methods: In a sample of subjects undergoing routine diagnostic testing, SARS-CoV-2 positivity of nasopharyngeal samples was assayed with both molecular (Altona Diagnostics RealStar SARS-CoV-2 RT-PCR Kit) and antigenic (Roche SARS-CoV-2 Rapid Antigen Test) tests. Positivization time of rapid antigen test was correlated and compared with viral load expressed as mean of SARS-CoV2 E/S genes cycle threshold (Ct) values.
Results: The study sample consisted of 106 patients (median age 48 years, 55 women) with positive results of rapid SARS-CoV-2 antigen testing. A highly significant Spearman's correlation was found between mean SARSCoV-2 E/S genes Ct values and positivization time of manual antigen test (r= 0.70; p<0.001). The positivization time of rapid SARS-CoV-2 antigen test displayed an area under the curve of 0.82 (95%CI, 0.74-0.89) for predicting nasopharyngeal samples with high viral load (i.e., mean Ct <20). A positivization time cut-off of 32 SEC had 94.9% sensitivity and 58.2% specificity for detecting specimens with high viral load. The overall agreement between mean Ct value <20 and positivization time <32 SEC was 70.8%.
Conclusions: Positivization time of rapid SARS-CoV-2 antigen tests may provide easy and rapid information on viral load, thus making this type of manual assay potentially suitable for quick and reliable detection and isolation of supercarriers.
期刊介绍:
The JOURNAL OF MEDICAL BIOCHEMISTRY (J MED BIOCHEM) is the official journal of the Society of Medical Biochemists of Serbia with international peer-review. Papers are independently reviewed by at least two reviewers selected by the Editors as Blind Peer Reviews. The Journal of Medical Biochemistry is published quarterly.
The Journal publishes original scientific and specialized articles on all aspects of
clinical and medical biochemistry,
molecular medicine,
clinical hematology and coagulation,
clinical immunology and autoimmunity,
clinical microbiology,
virology,
clinical genomics and molecular biology,
genetic epidemiology,
drug measurement,
evaluation of diagnostic markers,
new reagents and laboratory equipment,
reference materials and methods,
reference values,
laboratory organization,
automation,
quality control,
clinical metrology,
all related scientific disciplines where chemistry, biochemistry, molecular biology and immunochemistry deal with the study of normal and pathologic processes in human beings.