两种多焦人工晶状体对晶状体倾斜和离体的容忍度:采用快速对比敏感度函数法。

IF 5.4 3区 材料科学 Q2 CHEMISTRY, PHYSICAL ACS Applied Energy Materials Pub Date : 2022-12-01 DOI:10.1186/s40662-022-00317-y
Dongling Guo, Jiaqi Meng, Keke Zhang, Wenwen He, Shiyu Ma, Zhong-Lin Lu, Yi Lu, Xiangjia Zhu
{"title":"两种多焦人工晶状体对晶状体倾斜和离体的容忍度:采用快速对比敏感度函数法。","authors":"Dongling Guo,&nbsp;Jiaqi Meng,&nbsp;Keke Zhang,&nbsp;Wenwen He,&nbsp;Shiyu Ma,&nbsp;Zhong-Lin Lu,&nbsp;Yi Lu,&nbsp;Xiangjia Zhu","doi":"10.1186/s40662-022-00317-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) evaluation. This study evaluated the contrast sensitivity (CS) of eyes undergoing cataract surgery with multifocal intraocular lens (IOL) implantation and its tolerance to IOL tilt and IOL decentration using the qCSF method.</p><p><strong>Methods: </strong>Patients undergoing uneventful phacoemulsification and a trifocal IOL (Zeiss AT LISA tri 839MP, Carl Zeiss, Germany) or an extended depth-of-focus (EDOF) IOL (Tecnis Symfony ZXR00, Johnson & Johnsons, USA) implantation were included. Monocular contrast sensitivity was measured using the qCSF method at one month post-surgery. IOL tilt and decentration were measured using an optical aberrometer (OPD-Scan III, NIDEK, Japan).</p><p><strong>Results: </strong>Seventy-two patients/eyes with the 839MP IOL and 64 patients/eyes with the ZXR00 IOL were included. Area under the log CSF (AULCSF) and CS acuity did not differ significantly between the two groups. The ZXR00 IOL group showed better CS at 1 cpd (1.137 ± 0.164 vs. 1.030 ± 0.183 logCS) and 1.5 cpd (1.163 ± 0.163 vs. 1.071 ± 0.161 logCS), while the 839MP IOL group had better CS at 6 cpd (0.855 ± 0.187 vs. 0.735 ± 0.363 logCS). In the 839MP IOL group, all CSF metrics were negatively correlated with IOL tilt (all P < 0.05), while in the ZXR00 IOL group, the CS at 3 cpd had no significant correlation with IOL tilt (P > 0.05). Among myopic eyes, fewer CSF metrics were negatively correlated with IOL tilt in the ZXR00 IOL group than in the 839MP IOL group. No significant correlation was found between CSF metrics and IOL decentration.</p><p><strong>Conclusions: </strong>The ZXR00 and the 839MP IOL groups presented comparable CSF. CS was negatively correlated with IOL tilt, instead of decentration in multifocal IOLs, particularly among myopic eyes. The ZXR00 IOL had better tolerance to IOL tilt in myopic eyes.</p>","PeriodicalId":4,"journal":{"name":"ACS Applied Energy Materials","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9713962/pdf/","citationCount":"3","resultStr":"{\"title\":\"Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method.\",\"authors\":\"Dongling Guo,&nbsp;Jiaqi Meng,&nbsp;Keke Zhang,&nbsp;Wenwen He,&nbsp;Shiyu Ma,&nbsp;Zhong-Lin Lu,&nbsp;Yi Lu,&nbsp;Xiangjia Zhu\",\"doi\":\"10.1186/s40662-022-00317-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) evaluation. This study evaluated the contrast sensitivity (CS) of eyes undergoing cataract surgery with multifocal intraocular lens (IOL) implantation and its tolerance to IOL tilt and IOL decentration using the qCSF method.</p><p><strong>Methods: </strong>Patients undergoing uneventful phacoemulsification and a trifocal IOL (Zeiss AT LISA tri 839MP, Carl Zeiss, Germany) or an extended depth-of-focus (EDOF) IOL (Tecnis Symfony ZXR00, Johnson & Johnsons, USA) implantation were included. Monocular contrast sensitivity was measured using the qCSF method at one month post-surgery. IOL tilt and decentration were measured using an optical aberrometer (OPD-Scan III, NIDEK, Japan).</p><p><strong>Results: </strong>Seventy-two patients/eyes with the 839MP IOL and 64 patients/eyes with the ZXR00 IOL were included. Area under the log CSF (AULCSF) and CS acuity did not differ significantly between the two groups. The ZXR00 IOL group showed better CS at 1 cpd (1.137 ± 0.164 vs. 1.030 ± 0.183 logCS) and 1.5 cpd (1.163 ± 0.163 vs. 1.071 ± 0.161 logCS), while the 839MP IOL group had better CS at 6 cpd (0.855 ± 0.187 vs. 0.735 ± 0.363 logCS). In the 839MP IOL group, all CSF metrics were negatively correlated with IOL tilt (all P < 0.05), while in the ZXR00 IOL group, the CS at 3 cpd had no significant correlation with IOL tilt (P > 0.05). Among myopic eyes, fewer CSF metrics were negatively correlated with IOL tilt in the ZXR00 IOL group than in the 839MP IOL group. No significant correlation was found between CSF metrics and IOL decentration.</p><p><strong>Conclusions: </strong>The ZXR00 and the 839MP IOL groups presented comparable CSF. CS was negatively correlated with IOL tilt, instead of decentration in multifocal IOLs, particularly among myopic eyes. The ZXR00 IOL had better tolerance to IOL tilt in myopic eyes.</p>\",\"PeriodicalId\":4,\"journal\":{\"name\":\"ACS Applied Energy Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9713962/pdf/\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Energy Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40662-022-00317-y\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, PHYSICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Energy Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40662-022-00317-y","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 3

摘要

背景:快速对比灵敏度函数(qCSF)法是一种先进的快速对比灵敏度函数(CSF)评价方法。本研究采用qCSF方法评价白内障手术多焦人工晶状体(IOL)植入术后眼的对比敏感度(CS)及其对IOL倾斜和离体的耐受性。方法:采用超声乳化术和三焦人工晶体(蔡司AT LISA tri 839MP,卡尔蔡司,德国)或扩大聚焦深度(EDOF)人工晶体(Tecnis Symfony ZXR00,强生公司,美国)植入术的患者。术后1个月采用qCSF法测定单眼对比敏感度。使用光学像差仪(OPD-Scan III, NIDEK, Japan)测量IOL倾斜和离体。结果:839MP人工晶状体72例/眼,ZXR00人工晶状体64例/眼。两组脑脊液下面积(AULCSF)和CS视力无显著差异。ZXR00 IOL组在1 cpd(1.137±0.164比1.030±0.183 logCS)和1.5 cpd(1.163±0.163比1.071±0.161 logCS)时CS较好,839MP IOL组在6 cpd(0.855±0.187比0.735±0.363 logCS)时CS较好。在839MP的IOL组中,所有CSF指标与IOL倾斜呈负相关(均P < 0.05)。在近视眼中,与839MP IOL组相比,ZXR00 IOL组CSF指标与IOL倾斜负相关较少。脑脊液指标与人工晶状体脱位无显著相关性。结论:ZXR00和839MP IOL组脑脊液具有可比性。在多焦IOL中,CS与IOL倾斜呈负相关,而与分散性呈负相关,尤其是在近视眼中。ZXR00型人工晶状体对近视眼的人工晶状体倾斜有较好的耐受性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Tolerance to lens tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method.

Background: Quick contrast sensitivity function (qCSF) method is an advanced quick method for contrast sensitivity function (CSF) evaluation. This study evaluated the contrast sensitivity (CS) of eyes undergoing cataract surgery with multifocal intraocular lens (IOL) implantation and its tolerance to IOL tilt and IOL decentration using the qCSF method.

Methods: Patients undergoing uneventful phacoemulsification and a trifocal IOL (Zeiss AT LISA tri 839MP, Carl Zeiss, Germany) or an extended depth-of-focus (EDOF) IOL (Tecnis Symfony ZXR00, Johnson & Johnsons, USA) implantation were included. Monocular contrast sensitivity was measured using the qCSF method at one month post-surgery. IOL tilt and decentration were measured using an optical aberrometer (OPD-Scan III, NIDEK, Japan).

Results: Seventy-two patients/eyes with the 839MP IOL and 64 patients/eyes with the ZXR00 IOL were included. Area under the log CSF (AULCSF) and CS acuity did not differ significantly between the two groups. The ZXR00 IOL group showed better CS at 1 cpd (1.137 ± 0.164 vs. 1.030 ± 0.183 logCS) and 1.5 cpd (1.163 ± 0.163 vs. 1.071 ± 0.161 logCS), while the 839MP IOL group had better CS at 6 cpd (0.855 ± 0.187 vs. 0.735 ± 0.363 logCS). In the 839MP IOL group, all CSF metrics were negatively correlated with IOL tilt (all P < 0.05), while in the ZXR00 IOL group, the CS at 3 cpd had no significant correlation with IOL tilt (P > 0.05). Among myopic eyes, fewer CSF metrics were negatively correlated with IOL tilt in the ZXR00 IOL group than in the 839MP IOL group. No significant correlation was found between CSF metrics and IOL decentration.

Conclusions: The ZXR00 and the 839MP IOL groups presented comparable CSF. CS was negatively correlated with IOL tilt, instead of decentration in multifocal IOLs, particularly among myopic eyes. The ZXR00 IOL had better tolerance to IOL tilt in myopic eyes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Energy Materials
ACS Applied Energy Materials Materials Science-Materials Chemistry
CiteScore
10.30
自引率
6.20%
发文量
1368
期刊介绍: ACS Applied Energy Materials is an interdisciplinary journal publishing original research covering all aspects of materials, engineering, chemistry, physics and biology relevant to energy conversion and storage. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important energy applications.
期刊最新文献
Red ginseng polysaccharide promotes ferroptosis in gastric cancer cells by inhibiting PI3K/Akt pathway through down-regulation of AQP3. Diagnostic value of 18F-PSMA-1007 PET/CT for predicting the pathological grade of prostate cancer. Correction. Wilms' tumor 1 -targeting cancer vaccine: Recent advancements and future perspectives. Toll-like receptor agonists as cancer vaccine adjuvants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1