利用语音识别实现助听器增益自我调节的可行性。

Donghyeon Yun, Yi Shen, Zhuohuang Zhang
{"title":"利用语音识别实现助听器增益自我调节的可行性。","authors":"Donghyeon Yun,&nbsp;Yi Shen,&nbsp;Zhuohuang Zhang","doi":"10.7776/ASK.2022.41.1.076","DOIUrl":null,"url":null,"abstract":"<p><p>Personal hearing devices, such as hearing aids, may be fine-tuned by allowing the users to conduct self-adjustment. Two self-adjustment procedures were developed to collect the listener preferred gains in six octave-frequency bands from 0.25 kHz to 8 kHz. These procedures were designed to allow rapid exploration of a multi-dimensional parameter space using a simple, one-dimensional user control interface (i.e., a programmable knob). The two procedures differ in whether the user interface controls the gains in all frequency bands simultaneously (Procedure A) or only the gain in one frequency band (Procedure B) on a given trial. Monte-Carlo simulations suggested that for both procedures the gain preference identified by simulated listeners rapidly converged to the ground-truth preferred gain profile over the first 20 trials. Initial behavioral evaluations of the self-adjustment procedures, in terms of test-retest reliability, were conducted using 20 young, normal-hearing listeners. Each estimate of the preferred gain profile took less than 20 minutes. The deviation between two separate estimates of the preferred gain profile, conducted at least a week apart, was about 10 dB ~ 15 dB.</p>","PeriodicalId":93823,"journal":{"name":"The journal of the Acoustical Society of Korea","volume":"41 1","pages":"76-86"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9378319/pdf/","citationCount":"0","resultStr":"{\"title\":\"Feasibility of hearing aid gain self-adjustment using speech recognition.\",\"authors\":\"Donghyeon Yun,&nbsp;Yi Shen,&nbsp;Zhuohuang Zhang\",\"doi\":\"10.7776/ASK.2022.41.1.076\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Personal hearing devices, such as hearing aids, may be fine-tuned by allowing the users to conduct self-adjustment. Two self-adjustment procedures were developed to collect the listener preferred gains in six octave-frequency bands from 0.25 kHz to 8 kHz. These procedures were designed to allow rapid exploration of a multi-dimensional parameter space using a simple, one-dimensional user control interface (i.e., a programmable knob). The two procedures differ in whether the user interface controls the gains in all frequency bands simultaneously (Procedure A) or only the gain in one frequency band (Procedure B) on a given trial. Monte-Carlo simulations suggested that for both procedures the gain preference identified by simulated listeners rapidly converged to the ground-truth preferred gain profile over the first 20 trials. Initial behavioral evaluations of the self-adjustment procedures, in terms of test-retest reliability, were conducted using 20 young, normal-hearing listeners. Each estimate of the preferred gain profile took less than 20 minutes. The deviation between two separate estimates of the preferred gain profile, conducted at least a week apart, was about 10 dB ~ 15 dB.</p>\",\"PeriodicalId\":93823,\"journal\":{\"name\":\"The journal of the Acoustical Society of Korea\",\"volume\":\"41 1\",\"pages\":\"76-86\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9378319/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The journal of the Acoustical Society of Korea\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7776/ASK.2022.41.1.076\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of the Acoustical Society of Korea","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7776/ASK.2022.41.1.076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/31 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

个人听力设备,如助听器,可以通过允许用户进行自我调整来微调。在0.25 kHz至8 kHz的六个倍频带中,开发了两种自我调节程序来收集听众的首选增益。这些程序被设计成允许使用简单的一维用户控制界面(即可编程旋钮)快速探索多维参数空间。这两种程序的不同之处在于,在给定的试验中,用户界面是同时控制所有频段的增益(程序A),还是只控制一个频段的增益(程序B)。蒙特卡罗模拟表明,在前20次试验中,模拟听者识别的增益偏好迅速收敛到基真偏好增益曲线。以20名听力正常的年轻听者为研究对象,对自我调整过程进行了初步的行为评估。每次优选增益曲线的估计用时不到20分钟。对首选增益曲线的两次单独估计之间的偏差,相隔至少一周,约为10 dB ~ 15 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Feasibility of hearing aid gain self-adjustment using speech recognition.

Personal hearing devices, such as hearing aids, may be fine-tuned by allowing the users to conduct self-adjustment. Two self-adjustment procedures were developed to collect the listener preferred gains in six octave-frequency bands from 0.25 kHz to 8 kHz. These procedures were designed to allow rapid exploration of a multi-dimensional parameter space using a simple, one-dimensional user control interface (i.e., a programmable knob). The two procedures differ in whether the user interface controls the gains in all frequency bands simultaneously (Procedure A) or only the gain in one frequency band (Procedure B) on a given trial. Monte-Carlo simulations suggested that for both procedures the gain preference identified by simulated listeners rapidly converged to the ground-truth preferred gain profile over the first 20 trials. Initial behavioral evaluations of the self-adjustment procedures, in terms of test-retest reliability, were conducted using 20 young, normal-hearing listeners. Each estimate of the preferred gain profile took less than 20 minutes. The deviation between two separate estimates of the preferred gain profile, conducted at least a week apart, was about 10 dB ~ 15 dB.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Feasibility of hearing aid gain self-adjustment using speech recognition.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1