液相色谱-质谱联用法测定人唾液中8-异前列腺素f2 α的建立与验证

IF 2 4区 医学 Q4 BIOCHEMISTRY & MOLECULAR BIOLOGY Journal of Medical Biochemistry Pub Date : 2022-10-15 DOI:10.5937/jomb0-33556
Zlatina Tomova, Desislav Tomov, Angelina Vlahova, Veneta Chaova-Gizdakova, Lyubka Yoanidu, Dobrin Svinarov
{"title":"液相色谱-质谱联用法测定人唾液中8-异前列腺素f2 α的建立与验证","authors":"Zlatina Tomova,&nbsp;Desislav Tomov,&nbsp;Angelina Vlahova,&nbsp;Veneta Chaova-Gizdakova,&nbsp;Lyubka Yoanidu,&nbsp;Dobrin Svinarov","doi":"10.5937/jomb0-33556","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Increased formation of reactive oxygen species may be caused by the ion release of the metal alloys used in prosthetic dental restorations due to the corrosion process. As products of lipid peroxidation, isoprostanes can be used as a marker for oxidative stress in the body. There are two significant advantages of using isoprostanes as an oxidative stress marker - presence in all fluids in the body and low reactivity. Saliva provides noninvasive, painless, and cost-effective sample collection and can be used as an alternative testing medium of blood and urine.</p><p><strong>Methods: </strong>This study presents the development and validation of a sample LC-MS/MS method to quantify 8-isoprostaglandin F2-a in human saliva using salt-out assisted liquid-liquid extraction (SALLE).</p><p><strong>Results: </strong>The selected sample preparation procedure optimized chromatographic separation and mass detection provided high recovery and sensitivity of the analysis. The calibration curve was obtained in the predefined range 25-329 ng/L with R2 larger than 0.995. Normalized matrix varied between 89.7 % and 113.5%. The method showed sufficient accuracy and precision - accuracy in the range 89.7 %-113.9 %, and precision between 2.3% and 5.4%.</p><p><strong>Conclusions: </strong>The proposed method is validated according to current EMA/FDA industrial guidance for bioanalysis and offers an appropriate level of sensitivity and sufficient accuracy and precision.</p>","PeriodicalId":16175,"journal":{"name":"Journal of Medical Biochemistry","volume":"41 4","pages":"466-473"},"PeriodicalIF":2.0000,"publicationDate":"2022-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618336/pdf/","citationCount":"4","resultStr":"{\"title\":\"Development and validation of an LC-MS/MS method for determination of 8-iso-prostaglandin f2 Alpha in human saliva.\",\"authors\":\"Zlatina Tomova,&nbsp;Desislav Tomov,&nbsp;Angelina Vlahova,&nbsp;Veneta Chaova-Gizdakova,&nbsp;Lyubka Yoanidu,&nbsp;Dobrin Svinarov\",\"doi\":\"10.5937/jomb0-33556\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Increased formation of reactive oxygen species may be caused by the ion release of the metal alloys used in prosthetic dental restorations due to the corrosion process. As products of lipid peroxidation, isoprostanes can be used as a marker for oxidative stress in the body. There are two significant advantages of using isoprostanes as an oxidative stress marker - presence in all fluids in the body and low reactivity. Saliva provides noninvasive, painless, and cost-effective sample collection and can be used as an alternative testing medium of blood and urine.</p><p><strong>Methods: </strong>This study presents the development and validation of a sample LC-MS/MS method to quantify 8-isoprostaglandin F2-a in human saliva using salt-out assisted liquid-liquid extraction (SALLE).</p><p><strong>Results: </strong>The selected sample preparation procedure optimized chromatographic separation and mass detection provided high recovery and sensitivity of the analysis. The calibration curve was obtained in the predefined range 25-329 ng/L with R2 larger than 0.995. Normalized matrix varied between 89.7 % and 113.5%. The method showed sufficient accuracy and precision - accuracy in the range 89.7 %-113.9 %, and precision between 2.3% and 5.4%.</p><p><strong>Conclusions: </strong>The proposed method is validated according to current EMA/FDA industrial guidance for bioanalysis and offers an appropriate level of sensitivity and sufficient accuracy and precision.</p>\",\"PeriodicalId\":16175,\"journal\":{\"name\":\"Journal of Medical Biochemistry\",\"volume\":\"41 4\",\"pages\":\"466-473\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2022-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9618336/pdf/\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Medical Biochemistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5937/jomb0-33556\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMISTRY & MOLECULAR BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Biochemistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5937/jomb0-33556","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 4

摘要

背景:假牙修复体中使用的金属合金在腐蚀过程中释放出离子,导致活性氧的形成增加。异前列腺素是脂质过氧化反应的产物,可作为机体氧化应激的标志物。使用异前列腺素作为氧化应激标志物有两个显著的优点——存在于体内所有液体中,并且反应性低。唾液提供无创、无痛和成本效益的样本收集,可以用作血液和尿液的替代测试介质。方法:建立并验证了盐出辅助液液萃取(SALLE)法定量人唾液中8-异前列腺素F2-a的LC-MS/MS方法。结果:所选择的样品制备工艺优化了色谱分离和质量检测,具有较高的分析回收率和灵敏度。在25 ~ 329 ng/L范围内可获得校准曲线,R2 > 0.995。归一化矩阵在89.7%到115%之间变化。该方法具有较好的准确度和精密度,准确度在89.7% ~ 113.9%之间,精密度在2.3% ~ 5.4%之间。结论:该方法符合EMA/FDA现行生物分析行业指南,具有适当的灵敏度和足够的准确度和精密度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development and validation of an LC-MS/MS method for determination of 8-iso-prostaglandin f2 Alpha in human saliva.

Background: Increased formation of reactive oxygen species may be caused by the ion release of the metal alloys used in prosthetic dental restorations due to the corrosion process. As products of lipid peroxidation, isoprostanes can be used as a marker for oxidative stress in the body. There are two significant advantages of using isoprostanes as an oxidative stress marker - presence in all fluids in the body and low reactivity. Saliva provides noninvasive, painless, and cost-effective sample collection and can be used as an alternative testing medium of blood and urine.

Methods: This study presents the development and validation of a sample LC-MS/MS method to quantify 8-isoprostaglandin F2-a in human saliva using salt-out assisted liquid-liquid extraction (SALLE).

Results: The selected sample preparation procedure optimized chromatographic separation and mass detection provided high recovery and sensitivity of the analysis. The calibration curve was obtained in the predefined range 25-329 ng/L with R2 larger than 0.995. Normalized matrix varied between 89.7 % and 113.5%. The method showed sufficient accuracy and precision - accuracy in the range 89.7 %-113.9 %, and precision between 2.3% and 5.4%.

Conclusions: The proposed method is validated according to current EMA/FDA industrial guidance for bioanalysis and offers an appropriate level of sensitivity and sufficient accuracy and precision.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Medical Biochemistry
Journal of Medical Biochemistry BIOCHEMISTRY & MOLECULAR BIOLOGY-
CiteScore
3.00
自引率
12.00%
发文量
60
审稿时长
>12 weeks
期刊介绍: The JOURNAL OF MEDICAL BIOCHEMISTRY (J MED BIOCHEM) is the official journal of the Society of Medical Biochemists of Serbia with international peer-review. Papers are independently reviewed by at least two reviewers selected by the Editors as Blind Peer Reviews. The Journal of Medical Biochemistry is published quarterly. The Journal publishes original scientific and specialized articles on all aspects of clinical and medical biochemistry, molecular medicine, clinical hematology and coagulation, clinical immunology and autoimmunity, clinical microbiology, virology, clinical genomics and molecular biology, genetic epidemiology, drug measurement, evaluation of diagnostic markers, new reagents and laboratory equipment, reference materials and methods, reference values, laboratory organization, automation, quality control, clinical metrology, all related scientific disciplines where chemistry, biochemistry, molecular biology and immunochemistry deal with the study of normal and pathologic processes in human beings.
期刊最新文献
The correlation between ultrasonographic morphology and structure of the left atrial appendage, blood flow velocity, and plasma galectin-3 levels with thrombus formation in the left atrial appendage of patients with atrial fibrillation. The role of serum magnesium in the prediction of acute kidney injury after total aortic arch replacement: A prospective observational study. The value of combined detection of specific immunoglobulin E, interleukin-6 and regulatory T cells in predicting the risk of postoperative recurrence in patients with eosinophilic chronic rhinosinusitis and nasal polyps. Can pharmacogenetics impact the therapeutic effect of cytarabine and anthracyclines in adult acute myeloid leukaemia patients?: A Serbian experience. Clinical value of serum SIRT1 combined with uterine hemodynamics in predicting disease severity and fetal growth restriction in preeclampsia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1