儿童和青少年声学咽鼻测量检查的可靠性。

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE eJournal of Oral Maxillofacial Research Pub Date : 2022-09-30 eCollection Date: 2022-07-01 DOI:10.5037/jomr.2022.13304
Camilla Hansen, Liselotte Sonnesen
{"title":"儿童和青少年声学咽鼻测量检查的可靠性。","authors":"Camilla Hansen,&nbsp;Liselotte Sonnesen","doi":"10.5037/jomr.2022.13304","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this cross-sectional study was to examine the method error and reliability of acoustic pharyngometry and rhinometry in children and adolescents and to describe the feasibility of these methods in a young population.</p><p><strong>Material and methods: </strong>The study sample included 35 healthy subjects in the age of 9 to 14 years. The subjects were randomly recruited for the present project in the period from June 2021 to February 2022. Repeated measurements of the upper airway dimensions in standing mirror position were performed by the use of Acoustic Pharyngometer and Rhinometer. Volume (cm<sup>3</sup>), calculated resistance (cm H<sub>2</sub>O/L/min), mean area (cm<sup>2</sup>), minimum cross-sectional area (MCA, cm<sup>2</sup>) and distance to MCA (cm) were examined. Method errors and reliability coefficients were evaluated using Dahlberg's formula and the Houston reliability coefficient. The feasibility of the methods were analysed using paired t-test and estimated by difference in drop-out rates.</p><p><strong>Results: </strong>No systematic error exhibited in the repeated measurements except volume in the left nostril (P = 0.017). The method errors of the acoustic pharyngometry and rhinometry were betweeen 0.0002 to 0.069 and 0.001 to 0.082 respectively. The Houston reliability coefficient for both methods were between 0.952 to 0.999. The acoustic pharyngometry was significantly more feasible compared to rhinometry (P < 0.001).</p><p><strong>Conclusions: </strong>The study shows that acoustic pharyngometry and rhinometry in the standing mirror position are reliable methods, with acoustic pharyngometry being even more feasible than rhinometry, which is why it is recommended to practice the methods with children and ensure reliability of results before registering measurements.</p>","PeriodicalId":53254,"journal":{"name":"eJournal of Oral Maxillofacial Research","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2022-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3c/8f/jomr-13-e4.PMC9617254.pdf","citationCount":"0","resultStr":"{\"title\":\"Reliability of Acoustic Pharyngometry and Rhinometry Examination in Children and Adolescents.\",\"authors\":\"Camilla Hansen,&nbsp;Liselotte Sonnesen\",\"doi\":\"10.5037/jomr.2022.13304\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of this cross-sectional study was to examine the method error and reliability of acoustic pharyngometry and rhinometry in children and adolescents and to describe the feasibility of these methods in a young population.</p><p><strong>Material and methods: </strong>The study sample included 35 healthy subjects in the age of 9 to 14 years. The subjects were randomly recruited for the present project in the period from June 2021 to February 2022. Repeated measurements of the upper airway dimensions in standing mirror position were performed by the use of Acoustic Pharyngometer and Rhinometer. Volume (cm<sup>3</sup>), calculated resistance (cm H<sub>2</sub>O/L/min), mean area (cm<sup>2</sup>), minimum cross-sectional area (MCA, cm<sup>2</sup>) and distance to MCA (cm) were examined. Method errors and reliability coefficients were evaluated using Dahlberg's formula and the Houston reliability coefficient. The feasibility of the methods were analysed using paired t-test and estimated by difference in drop-out rates.</p><p><strong>Results: </strong>No systematic error exhibited in the repeated measurements except volume in the left nostril (P = 0.017). The method errors of the acoustic pharyngometry and rhinometry were betweeen 0.0002 to 0.069 and 0.001 to 0.082 respectively. The Houston reliability coefficient for both methods were between 0.952 to 0.999. The acoustic pharyngometry was significantly more feasible compared to rhinometry (P < 0.001).</p><p><strong>Conclusions: </strong>The study shows that acoustic pharyngometry and rhinometry in the standing mirror position are reliable methods, with acoustic pharyngometry being even more feasible than rhinometry, which is why it is recommended to practice the methods with children and ensure reliability of results before registering measurements.</p>\",\"PeriodicalId\":53254,\"journal\":{\"name\":\"eJournal of Oral Maxillofacial Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-09-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/3c/8f/jomr-13-e4.PMC9617254.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"eJournal of Oral Maxillofacial Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5037/jomr.2022.13304\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/7/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"eJournal of Oral Maxillofacial Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5037/jomr.2022.13304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本横断面研究的目的是检查儿童和青少年声学咽测和鼻测的方法误差和可靠性,并描述这些方法在年轻人群中的可行性。材料与方法:研究对象为35名9 ~ 14岁的健康成人。本项目的受试者是在2021年6月至2022年2月期间随机招募的。使用声学咽计和鼻计重复测量立镜位上呼吸道尺寸。检测体积(cm3)、计算阻力(cm H2O/L/min)、平均面积(cm2)、最小横截面积(MCA, cm2)和到MCA的距离(cm)。采用Dahlberg公式和Houston可靠性系数对方法误差和可靠性系数进行了评估。采用配对t检验对方法的可行性进行分析,并通过退出率的差异进行估计。结果:除左鼻孔容积外,重复测量无系统误差(P = 0.017)。声学咽测法和鼻测法的误差分别在0.0002 ~ 0.069和0.001 ~ 0.082之间。两种方法的休斯敦信度系数均在0.952 ~ 0.999之间。与鼻测法相比,声学咽测法明显更可行(P < 0.001)。结论:本研究表明立镜位声咽测量法和鼻测量法是可靠的方法,其中声咽测量法比鼻测量法更可行,因此建议在登记测量前与儿童进行练习,确保结果的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reliability of Acoustic Pharyngometry and Rhinometry Examination in Children and Adolescents.

Objectives: The aim of this cross-sectional study was to examine the method error and reliability of acoustic pharyngometry and rhinometry in children and adolescents and to describe the feasibility of these methods in a young population.

Material and methods: The study sample included 35 healthy subjects in the age of 9 to 14 years. The subjects were randomly recruited for the present project in the period from June 2021 to February 2022. Repeated measurements of the upper airway dimensions in standing mirror position were performed by the use of Acoustic Pharyngometer and Rhinometer. Volume (cm3), calculated resistance (cm H2O/L/min), mean area (cm2), minimum cross-sectional area (MCA, cm2) and distance to MCA (cm) were examined. Method errors and reliability coefficients were evaluated using Dahlberg's formula and the Houston reliability coefficient. The feasibility of the methods were analysed using paired t-test and estimated by difference in drop-out rates.

Results: No systematic error exhibited in the repeated measurements except volume in the left nostril (P = 0.017). The method errors of the acoustic pharyngometry and rhinometry were betweeen 0.0002 to 0.069 and 0.001 to 0.082 respectively. The Houston reliability coefficient for both methods were between 0.952 to 0.999. The acoustic pharyngometry was significantly more feasible compared to rhinometry (P < 0.001).

Conclusions: The study shows that acoustic pharyngometry and rhinometry in the standing mirror position are reliable methods, with acoustic pharyngometry being even more feasible than rhinometry, which is why it is recommended to practice the methods with children and ensure reliability of results before registering measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
19
审稿时长
12 weeks
期刊最新文献
Outcome Difference between Short and Longer Dental Implants Placed Simultaneously with Alveolar Bone Augmentation: a Systematic Review and Meta-Analysis. The Use of Platelet-Rich Fibrin in Sinus Floor Augmentation Surgery: a Systematic Review. Attitudes of Oral Surgeons and Periodontists towards Immediate Dental Implant Placement. Can CAPRIN-1 Be Responsible for the Recurrence Potential of Odontogenic Keratocysts? Dental Implant Placement in the Maxilla Following Ridge Augmentation with Free Iliac Bone Graft and Oral Rehabilitation with Fixed Prosthesis: a Three-Year Follow-Up Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1