使用氦气替代载气对商业纺织或皮革产品中偶氮染料产生的伯芳香胺进行GC-MS分析。

Maiko Tahara, Tsuyoshi Kawakami, Yoshiaki Ikarashi
{"title":"使用氦气替代载气对商业纺织或皮革产品中偶氮染料产生的伯芳香胺进行GC-MS分析。","authors":"Maiko Tahara, Tsuyoshi Kawakami, Yoshiaki Ikarashi","doi":"10.1093/jaoacint/qsad116","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>In recent years, due to the global shortage of helium gas, the development of gas chromatography (GC) analytical methods using alternatives to helium carrier gases is necessary.</p><p><strong>Objective: </strong>The objective of this study was to examine the applicability of hydrogen and nitrogen as alternative carrier gases using the test method for azo compounds in the Act on Control of Household Products Containing Harmful Substances of Japan.</p><p><strong>Method: </strong>The gas chromatograph mass spectrometer (GC-MS) analytical method using hydrogen and nitrogen as alternative carrier gases was compared with a method using helium for 26 primary aromatic amines (PAAs) originated from azo dyes.</p><p><strong>Results: </strong>When hydrogen and nitrogen were used as carrier gases under the same conditions used during analysis using helium (same column, gas flow rate, oven temperature conditions, etc.), sufficient peak separation of 26 PAAs was obtained. The sensitivities of the methods using helium and hydrogen were comparable, whereas the sensitivity was lower when nitrogen was used, with the detection limits ranging from 1/220 to 1/25. However, all carrier gases achieved quantification at concentrations below the standard value (30 μg/g) of the Act on Control of Household Products Containing Harmful Substances, and the results were in agreement with the standard value for the target product.</p><p><strong>Conclusions: </strong>Our results indicated that hydrogen or nitrogen can be used as alternative carrier gases to helium for GC-MS analysis of azo compounds producing specific aromatic amines.</p><p><strong>Highlights: </strong>Using hydrogen or nitrogen as an alternative carrier gas to helium, azo compounds could be quantified with excellent accuracy.</p>","PeriodicalId":94064,"journal":{"name":"Journal of AOAC International","volume":" ","pages":"61-68"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"GC-MS Analysis of Primary Aromatic Amines Originated From Azo Dyes in Commercial Textile or Leather Products Using Helium Alternative Carrier Gases.\",\"authors\":\"Maiko Tahara, Tsuyoshi Kawakami, Yoshiaki Ikarashi\",\"doi\":\"10.1093/jaoacint/qsad116\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>In recent years, due to the global shortage of helium gas, the development of gas chromatography (GC) analytical methods using alternatives to helium carrier gases is necessary.</p><p><strong>Objective: </strong>The objective of this study was to examine the applicability of hydrogen and nitrogen as alternative carrier gases using the test method for azo compounds in the Act on Control of Household Products Containing Harmful Substances of Japan.</p><p><strong>Method: </strong>The gas chromatograph mass spectrometer (GC-MS) analytical method using hydrogen and nitrogen as alternative carrier gases was compared with a method using helium for 26 primary aromatic amines (PAAs) originated from azo dyes.</p><p><strong>Results: </strong>When hydrogen and nitrogen were used as carrier gases under the same conditions used during analysis using helium (same column, gas flow rate, oven temperature conditions, etc.), sufficient peak separation of 26 PAAs was obtained. The sensitivities of the methods using helium and hydrogen were comparable, whereas the sensitivity was lower when nitrogen was used, with the detection limits ranging from 1/220 to 1/25. However, all carrier gases achieved quantification at concentrations below the standard value (30 μg/g) of the Act on Control of Household Products Containing Harmful Substances, and the results were in agreement with the standard value for the target product.</p><p><strong>Conclusions: </strong>Our results indicated that hydrogen or nitrogen can be used as alternative carrier gases to helium for GC-MS analysis of azo compounds producing specific aromatic amines.</p><p><strong>Highlights: </strong>Using hydrogen or nitrogen as an alternative carrier gas to helium, azo compounds could be quantified with excellent accuracy.</p>\",\"PeriodicalId\":94064,\"journal\":{\"name\":\"Journal of AOAC International\",\"volume\":\" \",\"pages\":\"61-68\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of AOAC International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jaoacint/qsad116\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsad116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:近年来,由于全球氦气短缺,有必要开发使用氦气载气替代品的气相色谱分析方法。目的:本研究的目的是使用日本《含有有害物质的家用产品控制法》中偶氮化合物的测试方法来检验氢气和氮气作为替代载气的适用性一种使用氦气制备26种源自偶氮染料的伯芳香胺的方法。结果:当使用氢气和氮气作为载气,在使用氦气进行分析时使用的相同条件下(相同的柱、气体流速、烘箱温度条件等),获得了26种伯芳族胺的充分峰分离。使用氦气和氢气的方法的灵敏度相当,而使用氮气的灵敏度较低,检测限在1/220至1/25之间。然而,所有载气在低于标准值(30 μg/g),结果与目标产品的标准值一致。结论:我们的结果表明,氢气或氮气可以作为氦气的替代载气,用于产生特定芳香胺的偶氮化合物的GC-MS分析。亮点:使用氢气或氮气作为氦气的替代载气,偶氮化合物可以非常准确地定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
GC-MS Analysis of Primary Aromatic Amines Originated From Azo Dyes in Commercial Textile or Leather Products Using Helium Alternative Carrier Gases.

Background: In recent years, due to the global shortage of helium gas, the development of gas chromatography (GC) analytical methods using alternatives to helium carrier gases is necessary.

Objective: The objective of this study was to examine the applicability of hydrogen and nitrogen as alternative carrier gases using the test method for azo compounds in the Act on Control of Household Products Containing Harmful Substances of Japan.

Method: The gas chromatograph mass spectrometer (GC-MS) analytical method using hydrogen and nitrogen as alternative carrier gases was compared with a method using helium for 26 primary aromatic amines (PAAs) originated from azo dyes.

Results: When hydrogen and nitrogen were used as carrier gases under the same conditions used during analysis using helium (same column, gas flow rate, oven temperature conditions, etc.), sufficient peak separation of 26 PAAs was obtained. The sensitivities of the methods using helium and hydrogen were comparable, whereas the sensitivity was lower when nitrogen was used, with the detection limits ranging from 1/220 to 1/25. However, all carrier gases achieved quantification at concentrations below the standard value (30 μg/g) of the Act on Control of Household Products Containing Harmful Substances, and the results were in agreement with the standard value for the target product.

Conclusions: Our results indicated that hydrogen or nitrogen can be used as alternative carrier gases to helium for GC-MS analysis of azo compounds producing specific aromatic amines.

Highlights: Using hydrogen or nitrogen as an alternative carrier gas to helium, azo compounds could be quantified with excellent accuracy.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Validation of the QuEChERSER Method for 245 Pesticides and Environmental Contaminants in Barley and Hemp by Low-Pressure GC: Comparison of Triple Quadrupole MS/MS and Orbitrap HRMS for Qualitative and Quantitative Analysis. FraMiTrACR: A Sustainable and Economical Technology for Analytical Sample Preparation. Proof of Concept: Autonomous Machine Vision Software for Botanical Identification. Influence of Talc in Polypropylene on Total Fluorine Measurements Used as an Indicator of Per- and Polyfluoroalkyl Substances (PFAS). Validation of the Level 2 Modification for the Neogen® Molecular Detection Assay 2 - Salmonella Enteritidis/Salmonella Typhimurium Method for Detection of the Monophasic Variant Salmonella enterica  1,4,[5],12:-:1,2.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1