踝足矫形器对偏瘫脑卒中平板行走步态模式和时空指标的影响。

IF 1.5 4区 医学 Q3 REHABILITATION International Journal of Rehabilitation Research Pub Date : 2023-12-01 Epub Date: 2023-09-22 DOI:10.1097/MRR.0000000000000602
Kei Ohtsuka, Masahiko Mukaino, Junya Yamada, Matsuda Fumihiro, Hiroki Tanikawa, Kazuhiro Tsuchiyama, Toshio Teranishi, Eiichi Saitoh, Yohei Otaka
{"title":"踝足矫形器对偏瘫脑卒中平板行走步态模式和时空指标的影响。","authors":"Kei Ohtsuka,&nbsp;Masahiko Mukaino,&nbsp;Junya Yamada,&nbsp;Matsuda Fumihiro,&nbsp;Hiroki Tanikawa,&nbsp;Kazuhiro Tsuchiyama,&nbsp;Toshio Teranishi,&nbsp;Eiichi Saitoh,&nbsp;Yohei Otaka","doi":"10.1097/MRR.0000000000000602","DOIUrl":null,"url":null,"abstract":"<p><p>Ankle-foot orthosis (AFO) is known to correct abnormal gait patterns and improve walking stability and speed in patients with hemiparesis. To quantify these benefits in post-stroke gait, a three-dimensional motion analysis of gait pattern was conducted. Forty patients with hemiparesis were enrolled. A three-dimensional motion analysis system was used to analyze patients' treadmill walking with/without an AFO. Outcome measures were 12 abnormal gait indices (forefoot contact, knee extensor thrust, retropulsion of the hip, flexed-knee gait, medial whip in the stance phase, circumduction gait, hip hiking, insufficient knee flexion during the swing phase, excessive lateral shifting of the trunk, contralateral vaulting, excessive hip external rotation, and posterior pelvic tilt), calculated using kinematic data and spatiotemporal indices, and the symmetry index of double-stance and single-stance time and step length. Forefoot contact (without AFO vs. with AFO: 71.0 vs. 65.8, P < 0.001), circumduction gait (65.0 vs. 57.9, P < 0.001), and contralateral vaulting (78.2 vs. 72.2, P = 0.003) were significantly reduced, whereas excessive hip external rotation (53.7 vs. 62.8, P = 0.003) significantly increased during walking with an AFO. Hip hiking (77.1 vs. 71.7) showed marginal reduction with the use of AFO ( P = 0.096). The absolute symmetry index of double-stance time (21.9 vs. 16.1, P = 0.014) significantly decreased during walking with an AFO. AFO effectively mitigates abnormal gait patterns typical of hemiparetic gait. A 3D motion analysis system with clinically oriented indices can help assess intervention efficacy for gait abnormalities.</p>","PeriodicalId":14301,"journal":{"name":"International Journal of Rehabilitation Research","volume":" ","pages":"316-324"},"PeriodicalIF":1.5000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10619636/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of ankle-foot orthosis on gait pattern and spatiotemporal indices during treadmill walking in hemiparetic stroke.\",\"authors\":\"Kei Ohtsuka,&nbsp;Masahiko Mukaino,&nbsp;Junya Yamada,&nbsp;Matsuda Fumihiro,&nbsp;Hiroki Tanikawa,&nbsp;Kazuhiro Tsuchiyama,&nbsp;Toshio Teranishi,&nbsp;Eiichi Saitoh,&nbsp;Yohei Otaka\",\"doi\":\"10.1097/MRR.0000000000000602\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ankle-foot orthosis (AFO) is known to correct abnormal gait patterns and improve walking stability and speed in patients with hemiparesis. To quantify these benefits in post-stroke gait, a three-dimensional motion analysis of gait pattern was conducted. Forty patients with hemiparesis were enrolled. A three-dimensional motion analysis system was used to analyze patients' treadmill walking with/without an AFO. Outcome measures were 12 abnormal gait indices (forefoot contact, knee extensor thrust, retropulsion of the hip, flexed-knee gait, medial whip in the stance phase, circumduction gait, hip hiking, insufficient knee flexion during the swing phase, excessive lateral shifting of the trunk, contralateral vaulting, excessive hip external rotation, and posterior pelvic tilt), calculated using kinematic data and spatiotemporal indices, and the symmetry index of double-stance and single-stance time and step length. Forefoot contact (without AFO vs. with AFO: 71.0 vs. 65.8, P < 0.001), circumduction gait (65.0 vs. 57.9, P < 0.001), and contralateral vaulting (78.2 vs. 72.2, P = 0.003) were significantly reduced, whereas excessive hip external rotation (53.7 vs. 62.8, P = 0.003) significantly increased during walking with an AFO. Hip hiking (77.1 vs. 71.7) showed marginal reduction with the use of AFO ( P = 0.096). The absolute symmetry index of double-stance time (21.9 vs. 16.1, P = 0.014) significantly decreased during walking with an AFO. AFO effectively mitigates abnormal gait patterns typical of hemiparetic gait. A 3D motion analysis system with clinically oriented indices can help assess intervention efficacy for gait abnormalities.</p>\",\"PeriodicalId\":14301,\"journal\":{\"name\":\"International Journal of Rehabilitation Research\",\"volume\":\" \",\"pages\":\"316-324\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10619636/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Rehabilitation Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MRR.0000000000000602\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"REHABILITATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Rehabilitation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MRR.0000000000000602","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0

摘要

踝足矫形器(AFO)可以纠正偏瘫患者的异常步态模式,提高行走稳定性和速度。为了量化中风后步态的这些益处,对步态模式进行了三维运动分析。入选了40名偏瘫患者。使用三维运动分析系统来分析患者在有/没有AFO的情况下在跑步机上行走的情况。结果测量为12项异常步态指标(前掌接触、膝关节伸肌推力、髋关节后冲、膝关节屈曲步态、站立阶段的内侧鞭状步态、回旋步态、髋关节抬高、摆动阶段的膝关节屈曲不足、躯干过度侧移、对侧跳跃、髋关节过度外旋和骨盆后倾),利用运动学数据和时空指标计算,以及双站和单站时间和步长的对称性指标。前脚接触(无AFO与有AFO相比:71.0 vs.65.8,P<0.001)、回旋步态(65.0 vs.57.9,P<001)和对侧跳马(78.2 vs.72.2,P=0.003)显著减少,而在有AFO的行走过程中,过度的髋关节外旋(53.7 vs.62.8,P=0.005)显著增加。髋关节徒步(77.1 vs.71.7)随着AFO的使用而略有减少(P=0.096)。在使用AFO的步行过程中,双站时间的绝对对称指数(21.9 vs.16.1,P=0.014)显著降低。AFO有效地缓解了典型的偏瘫步态的异常步态模式。具有临床导向指标的3D运动分析系统可以帮助评估步态异常的干预效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of ankle-foot orthosis on gait pattern and spatiotemporal indices during treadmill walking in hemiparetic stroke.

Ankle-foot orthosis (AFO) is known to correct abnormal gait patterns and improve walking stability and speed in patients with hemiparesis. To quantify these benefits in post-stroke gait, a three-dimensional motion analysis of gait pattern was conducted. Forty patients with hemiparesis were enrolled. A three-dimensional motion analysis system was used to analyze patients' treadmill walking with/without an AFO. Outcome measures were 12 abnormal gait indices (forefoot contact, knee extensor thrust, retropulsion of the hip, flexed-knee gait, medial whip in the stance phase, circumduction gait, hip hiking, insufficient knee flexion during the swing phase, excessive lateral shifting of the trunk, contralateral vaulting, excessive hip external rotation, and posterior pelvic tilt), calculated using kinematic data and spatiotemporal indices, and the symmetry index of double-stance and single-stance time and step length. Forefoot contact (without AFO vs. with AFO: 71.0 vs. 65.8, P < 0.001), circumduction gait (65.0 vs. 57.9, P < 0.001), and contralateral vaulting (78.2 vs. 72.2, P = 0.003) were significantly reduced, whereas excessive hip external rotation (53.7 vs. 62.8, P = 0.003) significantly increased during walking with an AFO. Hip hiking (77.1 vs. 71.7) showed marginal reduction with the use of AFO ( P = 0.096). The absolute symmetry index of double-stance time (21.9 vs. 16.1, P = 0.014) significantly decreased during walking with an AFO. AFO effectively mitigates abnormal gait patterns typical of hemiparetic gait. A 3D motion analysis system with clinically oriented indices can help assess intervention efficacy for gait abnormalities.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
88
审稿时长
6-12 weeks
期刊介绍: International Journal of Rehabilitation Research is a quarterly, peer-reviewed, interdisciplinary forum for the publication of research into functioning, disability and contextual factors experienced by persons of all ages in both developed and developing societies. The wealth of information offered makes the journal a valuable resource for researchers, practitioners, and administrators in such fields as rehabilitation medicine, outcome measurement nursing, social and vocational rehabilitation/case management, return to work, special education, social policy, social work and social welfare, sociology, psychology, psychiatry assistive technology and environmental factors/disability. Areas of interest include functioning and disablement throughout the life cycle; rehabilitation programmes for persons with physical, sensory, mental and developmental disabilities; measurement of functioning and disability; special education and vocational rehabilitation; equipment access and transportation; information technology; independent living; consumer, legal, economic and sociopolitical aspects of functioning, disability and contextual factors.
期刊最新文献
The mediating role of kinesiophobia in pain intensity, physical function, and physical activity level in inflammatory arthritis. Technology for helping people with neuromotor, intellectual, and speech disabilities engage in leisure and communication activities: a proof-of-concept study. Efficacy of continuous passive motion compared to physiotherapy in rehabilitation after total knee replacement: a prospective randomized controlled non-inferiority trial. Understanding the multidimensionality of a concern for falling in people with unilateral transtibial amputation: a cross-sectional study. Responsiveness of the Australian Spasticity Assessment Scale to botulinum neurotoxin injection into spastic wrist flexors after acquired brain injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1