{"title":"安全增强型远程运动中心机械手的尺寸优化和逆运动学求解方法。","authors":"Fang Huang,&nbsp;Hongqiang Sang,&nbsp;Fen Liu,&nbsp;Rui Han","doi":"10.1002/rcs.2579","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>With the expansion of minimally invasive surgery (MIS) applications in surgery, the remote centre of motion (RCM) manipulator requires a more flexible workspace to meet different operation requirements. Thus, the mechanical structure and motion control of the RCM manipulator play important roles.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A multi-objective genetic algorithm was exploited to maximise the kinematic performance and obtain a compact structure of the RCM manipulator. An inverse kinematic solution method is proposed to meet task accuracy and kinematic singularity avoidance constraints for safety motion control.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Simulation results demonstrate that there are significant improvements in the reachable workspace inside the abdominal cavity, the flexibility of the workspace, kinematic performance, and compactness of the RCM manipulator. Experiments verify the feasibility of the prototype and the validity of the proposed inverse kinematic solution method.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>This enhances the adaptability and safety of the RCM manipulator and provides potential prospects for MIS application.</p>\n </section>\n </div>","PeriodicalId":50311,"journal":{"name":"International Journal of Medical Robotics and Computer Assisted Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2023-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dimensional optimisation and an inverse kinematic solution method of a safety-enhanced remote centre of motion manipulator\",\"authors\":\"Fang Huang,&nbsp;Hongqiang Sang,&nbsp;Fen Liu,&nbsp;Rui Han\",\"doi\":\"10.1002/rcs.2579\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>With the expansion of minimally invasive surgery (MIS) applications in surgery, the remote centre of motion (RCM) manipulator requires a more flexible workspace to meet different operation requirements. Thus, the mechanical structure and motion control of the RCM manipulator play important roles.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A multi-objective genetic algorithm was exploited to maximise the kinematic performance and obtain a compact structure of the RCM manipulator. An inverse kinematic solution method is proposed to meet task accuracy and kinematic singularity avoidance constraints for safety motion control.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Simulation results demonstrate that there are significant improvements in the reachable workspace inside the abdominal cavity, the flexibility of the workspace, kinematic performance, and compactness of the RCM manipulator. Experiments verify the feasibility of the prototype and the validity of the proposed inverse kinematic solution method.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>This enhances the adaptability and safety of the RCM manipulator and provides potential prospects for MIS application.</p>\\n </section>\\n </div>\",\"PeriodicalId\":50311,\"journal\":{\"name\":\"International Journal of Medical Robotics and Computer Assisted Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Medical Robotics and Computer Assisted Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2579\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Medical Robotics and Computer Assisted Surgery","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/rcs.2579","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

背景:随着微创手术(MIS)在外科手术中应用的扩展,远程运动中心(RCM)机械手需要更灵活的工作空间来满足不同的操作要求。因此,RCM机械手的机械结构和运动控制起着重要作用。方法:利用多目标遗传算法最大限度地提高RCM机械手的运动性能,获得紧凑的结构。为了满足安全运动控制的任务精度和运动奇异性回避约束,提出了一种逆运动学求解方法。结果:仿真结果表明,RCM机械手在腹腔内的可达工作空间、工作空间的灵活性、运动学性能和紧凑性方面都有显著改进。实验验证了原型的可行性和所提出的运动学逆解方法的有效性。结论:这提高了RCM机械手的适应性和安全性,为MIS的应用提供了潜在的前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dimensional optimisation and an inverse kinematic solution method of a safety-enhanced remote centre of motion manipulator

Background

With the expansion of minimally invasive surgery (MIS) applications in surgery, the remote centre of motion (RCM) manipulator requires a more flexible workspace to meet different operation requirements. Thus, the mechanical structure and motion control of the RCM manipulator play important roles.

Methods

A multi-objective genetic algorithm was exploited to maximise the kinematic performance and obtain a compact structure of the RCM manipulator. An inverse kinematic solution method is proposed to meet task accuracy and kinematic singularity avoidance constraints for safety motion control.

Results

Simulation results demonstrate that there are significant improvements in the reachable workspace inside the abdominal cavity, the flexibility of the workspace, kinematic performance, and compactness of the RCM manipulator. Experiments verify the feasibility of the prototype and the validity of the proposed inverse kinematic solution method.

Conclusions

This enhances the adaptability and safety of the RCM manipulator and provides potential prospects for MIS application.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.50
自引率
12.00%
发文量
131
审稿时长
6-12 weeks
期刊介绍: The International Journal of Medical Robotics and Computer Assisted Surgery provides a cross-disciplinary platform for presenting the latest developments in robotics and computer assisted technologies for medical applications. The journal publishes cutting-edge papers and expert reviews, complemented by commentaries, correspondence and conference highlights that stimulate discussion and exchange of ideas. Areas of interest include robotic surgery aids and systems, operative planning tools, medical imaging and visualisation, simulation and navigation, virtual reality, intuitive command and control systems, haptics and sensor technologies. In addition to research and surgical planning studies, the journal welcomes papers detailing clinical trials and applications of computer-assisted workflows and robotic systems in neurosurgery, urology, paediatric, orthopaedic, craniofacial, cardiovascular, thoraco-abdominal, musculoskeletal and visceral surgery. Articles providing critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies, commenting on ease of use, or addressing surgical education and training issues are also encouraged. The journal aims to foster a community that encompasses medical practitioners, researchers, and engineers and computer scientists developing robotic systems and computational tools in academic and commercial environments, with the intention of promoting and developing these exciting areas of medical technology.
期刊最新文献
Robotic Left Hepatectomy Using the Glissonean Approach and Saline-Linked Bipolar Clamp-Crush Technique This is the first in-human trial and prospective case series of a novel single-port robotic system for gynaecological surgery: An IDEAL stage 2a study Initial Experience of Robot Assisted Laparoscopic Pyeloplasty for Ureteropelvic Junction Obstruction Using the Hinotori Surgical Robot System Design and Modelling of Continuum Robot for Endoscopic Submucosal Dissection Surgery With Lifting Force Estimation Robot-Assisted Ocular Tumour Radiotherapy Positioning and Tracking System
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1