线性四极中的偶极和四极共振激发。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-02-01 Epub Date: 2023-10-11 DOI:10.1177/14690667231204359
N V Konenkov
{"title":"线性四极中的偶极和四极共振激发。","authors":"N V Konenkov","doi":"10.1177/14690667231204359","DOIUrl":null,"url":null,"abstract":"<p><p>In the development of commercial quadrupole mass spectrometers, there is an interest in improving the performance characteristics such as transmission, resolution, and mass range. In particular, parametric and dipolar resonance excitation of trapping ions are used for linear quadrupole mass filters. Theoretical methods and numerical simulation of ion trajectories were applied for study of ion-optical properties. The review is devoted to description of different excitation methods to improve QMF performance and consists of three parts. The first part presents the results of a linear ion trap simulation for various operating conditions and excitation methods. The second part considers the effects of dipole excitation (DE) on the performance of the quadrupole mass filter. The last part analyzes the formation of stability islands by different methods of quadrupole excitation. To date conditions of mass separation in quadrupole mass filters with sin wave supply were described for stability islands of the first and third stability regions formed by quadrupole and DE. By complicating the electronics such methods allow to overcome the destructive influence of electric field distortions and obtain a resolving power and ion transmission efficiency comparable with commercial devices. At quadrupole resonance excitation by a two-frequency signal, it is possible to reduce the length of electrodes three times without losses in resolution and transmission, which reduces the cost of rod set production with micrometer accuracy. Dipole resonance excitation allows controlling the shape of the mass peak by changing amplitude and phase of the auxiliary AC signal. The main factors affecting the resolving power of a linear ion trap are described theoretically. The numerical modeling results are confirmed by experiment.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dipole and quadrupole resonance excitation in linear quadrupoles.\",\"authors\":\"N V Konenkov\",\"doi\":\"10.1177/14690667231204359\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In the development of commercial quadrupole mass spectrometers, there is an interest in improving the performance characteristics such as transmission, resolution, and mass range. In particular, parametric and dipolar resonance excitation of trapping ions are used for linear quadrupole mass filters. Theoretical methods and numerical simulation of ion trajectories were applied for study of ion-optical properties. The review is devoted to description of different excitation methods to improve QMF performance and consists of three parts. The first part presents the results of a linear ion trap simulation for various operating conditions and excitation methods. The second part considers the effects of dipole excitation (DE) on the performance of the quadrupole mass filter. The last part analyzes the formation of stability islands by different methods of quadrupole excitation. To date conditions of mass separation in quadrupole mass filters with sin wave supply were described for stability islands of the first and third stability regions formed by quadrupole and DE. By complicating the electronics such methods allow to overcome the destructive influence of electric field distortions and obtain a resolving power and ion transmission efficiency comparable with commercial devices. At quadrupole resonance excitation by a two-frequency signal, it is possible to reduce the length of electrodes three times without losses in resolution and transmission, which reduces the cost of rod set production with micrometer accuracy. Dipole resonance excitation allows controlling the shape of the mass peak by changing amplitude and phase of the auxiliary AC signal. The main factors affecting the resolving power of a linear ion trap are described theoretically. The numerical modeling results are confirmed by experiment.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1177/14690667231204359\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/11 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/14690667231204359","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

在商用四极质谱仪的开发中,人们对改善透射、分辨率和质量范围等性能特性感兴趣。特别地,捕获离子的参数和偶极共振激发用于线性四极质量滤波器。将离子轨道的理论方法和数值模拟应用于离子光学性质的研究。该综述专门描述了提高QMF性能的不同激励方法,包括三个部分。第一部分介绍了不同操作条件和激发方法下的线性离子阱模拟结果。第二部分考虑了偶极激励对四极质量滤波器性能的影响。最后一部分分析了不同四极激发方法下稳定岛的形成。针对四极和DE形成的第一和第三稳定区的稳定岛,描述了具有正弦波供应的四极质量滤波器中的质量分离的最新条件。通过使电子器件复杂化,这种方法允许克服电场失真的破坏性影响,并获得与商业设备相当的分辨能力和离子传输效率。在双频信号的四极共振激励下,可以在不损失分辨率和传输的情况下将电极的长度减少三倍,这降低了具有微米精度的棒组生产的成本。偶极共振激励允许通过改变辅助AC信号的振幅和相位来控制质量峰值的形状。从理论上描述了影响线性离子阱分辨能力的主要因素。数值模拟结果经实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dipole and quadrupole resonance excitation in linear quadrupoles.

In the development of commercial quadrupole mass spectrometers, there is an interest in improving the performance characteristics such as transmission, resolution, and mass range. In particular, parametric and dipolar resonance excitation of trapping ions are used for linear quadrupole mass filters. Theoretical methods and numerical simulation of ion trajectories were applied for study of ion-optical properties. The review is devoted to description of different excitation methods to improve QMF performance and consists of three parts. The first part presents the results of a linear ion trap simulation for various operating conditions and excitation methods. The second part considers the effects of dipole excitation (DE) on the performance of the quadrupole mass filter. The last part analyzes the formation of stability islands by different methods of quadrupole excitation. To date conditions of mass separation in quadrupole mass filters with sin wave supply were described for stability islands of the first and third stability regions formed by quadrupole and DE. By complicating the electronics such methods allow to overcome the destructive influence of electric field distortions and obtain a resolving power and ion transmission efficiency comparable with commercial devices. At quadrupole resonance excitation by a two-frequency signal, it is possible to reduce the length of electrodes three times without losses in resolution and transmission, which reduces the cost of rod set production with micrometer accuracy. Dipole resonance excitation allows controlling the shape of the mass peak by changing amplitude and phase of the auxiliary AC signal. The main factors affecting the resolving power of a linear ion trap are described theoretically. The numerical modeling results are confirmed by experiment.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Mentorship in academic musculoskeletal radiology: perspectives from a junior faculty member. Underlying synovial sarcoma undiagnosed for more than 20 years in a patient with regional pain: a case report. Sacrococcygeal chordoma with spontaneous regression due to a large hemorrhagic component. Associations of cumulative voriconazole dose, treatment duration, and alkaline phosphatase with voriconazole-induced periostitis. Can the presence of SLAP-5 lesions be predicted by using the critical shoulder angle in traumatic anterior shoulder instability?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1