超声引导电极置入及神经动作电位检测的临床应用。

IF 0.9 4区 医学 Q4 CLINICAL NEUROLOGY Journal of neurological surgery. Part A, Central European neurosurgery Pub Date : 2024-11-01 Epub Date: 2022-05-03 DOI:10.1055/a-1842-4343
Dong Han, Le Xu, Jianguang Xu
{"title":"超声引导电极置入及神经动作电位检测的临床应用。","authors":"Dong Han, Le Xu, Jianguang Xu","doi":"10.1055/a-1842-4343","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> We explore a minimally invasive method (combined ultrasound detection, electrode placement and electrophysiologic nerve examination) to evaluate the early-stage quality of a nerve suture site.</p><p><strong>Methods: </strong> Ten patients with median and/or ulnar nerve injuries who had undergone nerve suture were recruited. Postoperative ultrasound examination found that the nerve injury was sutured. Then, a stimulating electrode and recording electrode were located beside the nerve proximal and distal to the suture site guided by ultrasound. Measurement of nerve action potentials (NAP) were performed with these electrodes, followed by surgical exploration. The pre- and intraoperative electrophysiologic findings were compared, together with amplitude, latency, and wave shape of NAP.</p><p><strong>Results: </strong> Of the 10 patients, 3 patients were diagnosed with median nerve injury, 2 with ulnar nerve injury, and 5 with the median nerve and ulnar nerve injury. NAP could not be detected pre- and intraoperatively in three median nerves from three patients and in two ulnar nerves from two patients. NAP was detected in 10 nerves from the remaining 5 patients. The pre- and intraoperative NAP results showed consistent results concerning the status of the nerve suture. Wilcoxon's signed-rank test indicated no significant difference in the amplitude and latency detected via sonographically placed electrodes and during surgical exploration. The number of negative-phase waves were equally distributed.</p><p><strong>Conclusion: </strong> Ultrasound-guided electrode placement and NAP detection can substitute surgery and serve as a minimally invasive approach to evaluate the regeneration of a sutured nerve.</p>","PeriodicalId":16544,"journal":{"name":"Journal of neurological surgery. Part A, Central European neurosurgery","volume":" ","pages":"594-601"},"PeriodicalIF":0.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Application of Ultrasound-guided Electrode Placement and Detection of Nerve Action Potential.\",\"authors\":\"Dong Han, Le Xu, Jianguang Xu\",\"doi\":\"10.1055/a-1842-4343\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong> We explore a minimally invasive method (combined ultrasound detection, electrode placement and electrophysiologic nerve examination) to evaluate the early-stage quality of a nerve suture site.</p><p><strong>Methods: </strong> Ten patients with median and/or ulnar nerve injuries who had undergone nerve suture were recruited. Postoperative ultrasound examination found that the nerve injury was sutured. Then, a stimulating electrode and recording electrode were located beside the nerve proximal and distal to the suture site guided by ultrasound. Measurement of nerve action potentials (NAP) were performed with these electrodes, followed by surgical exploration. The pre- and intraoperative electrophysiologic findings were compared, together with amplitude, latency, and wave shape of NAP.</p><p><strong>Results: </strong> Of the 10 patients, 3 patients were diagnosed with median nerve injury, 2 with ulnar nerve injury, and 5 with the median nerve and ulnar nerve injury. NAP could not be detected pre- and intraoperatively in three median nerves from three patients and in two ulnar nerves from two patients. NAP was detected in 10 nerves from the remaining 5 patients. The pre- and intraoperative NAP results showed consistent results concerning the status of the nerve suture. Wilcoxon's signed-rank test indicated no significant difference in the amplitude and latency detected via sonographically placed electrodes and during surgical exploration. The number of negative-phase waves were equally distributed.</p><p><strong>Conclusion: </strong> Ultrasound-guided electrode placement and NAP detection can substitute surgery and serve as a minimally invasive approach to evaluate the regeneration of a sutured nerve.</p>\",\"PeriodicalId\":16544,\"journal\":{\"name\":\"Journal of neurological surgery. Part A, Central European neurosurgery\",\"volume\":\" \",\"pages\":\"594-601\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of neurological surgery. Part A, Central European neurosurgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1055/a-1842-4343\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/5/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurological surgery. Part A, Central European neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-1842-4343","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/5/3 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景: 我们探索了一种微创方法(结合超声检测、电极放置和神经电生理检查)来评估神经缝合部位的早期质量。方法: 招募了10名接受神经缝合的正中神经和/或尺神经损伤患者。术后超声检查发现神经损伤已缝合。然后,在超声引导下,在缝合部位的近端和远端的神经旁放置刺激电极和记录电极。用这些电极测量神经动作电位(NAP),然后进行手术探查。比较术前和术中的电生理结果,以及NAP的振幅、潜伏期和波形。结果: 10例患者中,3例诊断为正中神经损伤,2例诊断为尺神经损伤,5例诊断为中神经和尺神经损伤。三名患者的三条正中神经和两名患者的两条尺神经在术前和术中均未检测到NAP。在其余5名患者的10条神经中检测到NAP。术前和术中NAP结果显示,神经缝合状态的结果一致。Wilcoxon的符号秩检验表明,通过超声放置电极和手术探查检测到的振幅和潜伏期没有显著差异。负相位波的数量分布均匀。结论: 超声引导的电极放置和NAP检测可以代替手术,并作为评估缝合神经再生的微创方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical Application of Ultrasound-guided Electrode Placement and Detection of Nerve Action Potential.

Background:  We explore a minimally invasive method (combined ultrasound detection, electrode placement and electrophysiologic nerve examination) to evaluate the early-stage quality of a nerve suture site.

Methods:  Ten patients with median and/or ulnar nerve injuries who had undergone nerve suture were recruited. Postoperative ultrasound examination found that the nerve injury was sutured. Then, a stimulating electrode and recording electrode were located beside the nerve proximal and distal to the suture site guided by ultrasound. Measurement of nerve action potentials (NAP) were performed with these electrodes, followed by surgical exploration. The pre- and intraoperative electrophysiologic findings were compared, together with amplitude, latency, and wave shape of NAP.

Results:  Of the 10 patients, 3 patients were diagnosed with median nerve injury, 2 with ulnar nerve injury, and 5 with the median nerve and ulnar nerve injury. NAP could not be detected pre- and intraoperatively in three median nerves from three patients and in two ulnar nerves from two patients. NAP was detected in 10 nerves from the remaining 5 patients. The pre- and intraoperative NAP results showed consistent results concerning the status of the nerve suture. Wilcoxon's signed-rank test indicated no significant difference in the amplitude and latency detected via sonographically placed electrodes and during surgical exploration. The number of negative-phase waves were equally distributed.

Conclusion:  Ultrasound-guided electrode placement and NAP detection can substitute surgery and serve as a minimally invasive approach to evaluate the regeneration of a sutured nerve.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
90
期刊介绍: The Journal of Neurological Surgery Part A: Central European Neurosurgery (JNLS A) is a major publication from the world''s leading publisher in neurosurgery. JNLS A currently serves as the official organ of several national neurosurgery societies. JNLS A is a peer-reviewed journal publishing original research, review articles, and technical notes covering all aspects of neurological surgery. The focus of JNLS A includes microsurgery as well as the latest minimally invasive techniques, such as stereotactic-guided surgery, endoscopy, and endovascular procedures. JNLS A covers purely neurosurgical topics.
期刊最新文献
A New Concept for Cervical Expansion Screws Using Shape Memory Alloy: A Feasibility Study. Artificial Intelligence Prediction Model of Occurrence of Cerebral Vasospasms Based on Machine Learning. Paresis of the Oculomotor Nerve due to Neurovascular Conflict with Superior Cerebellar Artery. EFFECT OF KYPHOPLASTY ON PAIN CONTROL AND VERTEBRAL RESTORATION. First experience using a new minimally invasive screw-rod system for completely percutaneous pedicle screw fixation of the cervical spine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1