{"title":"压力控制阀的静态特性","authors":"Ondřej Vykoukal, L. Hružík, Adam Bureček","doi":"10.1515/scjme-2017-0012","DOIUrl":null,"url":null,"abstract":"Abstract The article deals with the measurement of static characteristics of a pressure control valve. The pressure, at which the valve starts to leak oil, is adjusted by a spring. The measurement is performed on a hydraulic system that consists of tank, hydraulic pump, check valve, relief valve and pressure control valve which is measured. The results of this experimental measurement are Δp - Q characteristics of the pressure control valve for various pressure settings.","PeriodicalId":35968,"journal":{"name":"Strojnicky Casopis","volume":"252 ","pages":"119 - 124"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Static Characteristics of Pressure Control Valve\",\"authors\":\"Ondřej Vykoukal, L. Hružík, Adam Bureček\",\"doi\":\"10.1515/scjme-2017-0012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The article deals with the measurement of static characteristics of a pressure control valve. The pressure, at which the valve starts to leak oil, is adjusted by a spring. The measurement is performed on a hydraulic system that consists of tank, hydraulic pump, check valve, relief valve and pressure control valve which is measured. The results of this experimental measurement are Δp - Q characteristics of the pressure control valve for various pressure settings.\",\"PeriodicalId\":35968,\"journal\":{\"name\":\"Strojnicky Casopis\",\"volume\":\"252 \",\"pages\":\"119 - 124\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Strojnicky Casopis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1515/scjme-2017-0012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Strojnicky Casopis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/scjme-2017-0012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
Abstract The article deals with the measurement of static characteristics of a pressure control valve. The pressure, at which the valve starts to leak oil, is adjusted by a spring. The measurement is performed on a hydraulic system that consists of tank, hydraulic pump, check valve, relief valve and pressure control valve which is measured. The results of this experimental measurement are Δp - Q characteristics of the pressure control valve for various pressure settings.