MWA方案对肝脏消融区形态和IVIM参数的影响- mri兼容微波消融装置的初步体内动物研究。

IF 2.1 4区 医学 Q2 Medicine Diagnostic and Interventional Radiology Pub Date : 2022-03-01 DOI:10.5152/dir.2022.20292
Weitao Ye, Wanqun Yang, Cheng-wei Guo, Chenyu Dong, F. Shi, C. Liang
{"title":"MWA方案对肝脏消融区形态和IVIM参数的影响- mri兼容微波消融装置的初步体内动物研究。","authors":"Weitao Ye, Wanqun Yang, Cheng-wei Guo, Chenyu Dong, F. Shi, C. Liang","doi":"10.5152/dir.2022.20292","DOIUrl":null,"url":null,"abstract":"PURPOSE We aimed to explore the effect of microwave ablation (MWA) protocols upon morphology and instant changes in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters on MWA zones in porcine livers. METHODS According to the empirical protocol for MWA in tumors less than 3 cm in our hospital, the power and application duration were assigned as five groups: A, 60 W × 5 min (n = 6); B, 80 W × 3 min (n = 7); C, 80 W × 5 min (n = 10); D, 100 W × 3 min (n = 10); E, 100 W × 5 min (n = 9). Spearman correlation between MWA protocols, morphological metrics, and instant post-ablation IVIM parameters was performed. RESULTS There was fair positive correlation between energy delivery and short axis (RSpearman = 0.426, P= .005) of the white zone. There was moderate-to-good positive correlation between wattage and short axis (RSpearman = 0.584, P < .001) of the white zone. For post-ablation IVIM parameters in the white zone, only wattage had moderate-to-good positive correlation with D value (RSpearman= 0.574, P < .001) or ADC value (RSpearman = 0.550, P < .001). No correlation between energy delivery, wattage, duration, and f value was observed (RSpearman = 0.185, P = .24; RSpearman= - 0.001, P = .99; RSpearman = 0.203, P = .20, respectively). CONCLUSION The increase in the short axis of the white zone is more likely to be affected by wattage than energy delivery. The instant post-ablation IVIM is feasible in monitoring the MWA zones since the f value in the white zones is not sensitive to changes in MWA protocols, which is promising in evaluating the instant effect of MWA.","PeriodicalId":50582,"journal":{"name":"Diagnostic and Interventional Radiology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device.\",\"authors\":\"Weitao Ye, Wanqun Yang, Cheng-wei Guo, Chenyu Dong, F. Shi, C. Liang\",\"doi\":\"10.5152/dir.2022.20292\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE We aimed to explore the effect of microwave ablation (MWA) protocols upon morphology and instant changes in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters on MWA zones in porcine livers. METHODS According to the empirical protocol for MWA in tumors less than 3 cm in our hospital, the power and application duration were assigned as five groups: A, 60 W × 5 min (n = 6); B, 80 W × 3 min (n = 7); C, 80 W × 5 min (n = 10); D, 100 W × 3 min (n = 10); E, 100 W × 5 min (n = 9). Spearman correlation between MWA protocols, morphological metrics, and instant post-ablation IVIM parameters was performed. RESULTS There was fair positive correlation between energy delivery and short axis (RSpearman = 0.426, P= .005) of the white zone. There was moderate-to-good positive correlation between wattage and short axis (RSpearman = 0.584, P < .001) of the white zone. For post-ablation IVIM parameters in the white zone, only wattage had moderate-to-good positive correlation with D value (RSpearman= 0.574, P < .001) or ADC value (RSpearman = 0.550, P < .001). No correlation between energy delivery, wattage, duration, and f value was observed (RSpearman = 0.185, P = .24; RSpearman= - 0.001, P = .99; RSpearman = 0.203, P = .20, respectively). CONCLUSION The increase in the short axis of the white zone is more likely to be affected by wattage than energy delivery. The instant post-ablation IVIM is feasible in monitoring the MWA zones since the f value in the white zones is not sensitive to changes in MWA protocols, which is promising in evaluating the instant effect of MWA.\",\"PeriodicalId\":50582,\"journal\":{\"name\":\"Diagnostic and Interventional Radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2022-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and Interventional Radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5152/dir.2022.20292\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Interventional Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5152/dir.2022.20292","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的探讨微波消融(MWA)方案对猪肝MWA区形态及体素内非相干运动(IVIM)扩散加权成像(DWI)参数瞬时变化的影响。方法根据我院小于3cm肿瘤MWA的经验方案,将功率和使用时间分为5组:A、60 W × 5 min (n = 6);B, 80 W × 3 min (n = 7);C, 80 W × 5 min (n = 10);D, 100 W × 3 min (n = 10);E, 100 W × 5 min (n = 9)。对MWA方案、形态学指标和消融后即时IVIM参数进行Spearman相关性分析。结果能量传递与白区短轴呈显著正相关(RSpearman = 0.426, P= 0.005)。白带的瓦数与短轴呈中等至良好的正相关(RSpearman = 0.584, P < 0.001)。消融后白区IVIM参数中,只有瓦数与D值(RSpearman= 0.574, P < .001)或ADC值(RSpearman= 0.550, P < .001)呈正相关。能量输送、瓦数、持续时间和f值之间无相关性(RSpearman = 0.185, P = 0.24;RSpearman= - 0.001, P = 0.99;RSpearman = 0.203, P = 0.20)。结论白区短轴的增加更容易受到功率的影响,而不是能量输送的影响。消融后瞬间IVIM监测MWA区域是可行的,因为白色区域的f值对MWA协议的变化不敏感,这在评价MWA的即时效果方面是有希望的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device.
PURPOSE We aimed to explore the effect of microwave ablation (MWA) protocols upon morphology and instant changes in intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters on MWA zones in porcine livers. METHODS According to the empirical protocol for MWA in tumors less than 3 cm in our hospital, the power and application duration were assigned as five groups: A, 60 W × 5 min (n = 6); B, 80 W × 3 min (n = 7); C, 80 W × 5 min (n = 10); D, 100 W × 3 min (n = 10); E, 100 W × 5 min (n = 9). Spearman correlation between MWA protocols, morphological metrics, and instant post-ablation IVIM parameters was performed. RESULTS There was fair positive correlation between energy delivery and short axis (RSpearman = 0.426, P= .005) of the white zone. There was moderate-to-good positive correlation between wattage and short axis (RSpearman = 0.584, P < .001) of the white zone. For post-ablation IVIM parameters in the white zone, only wattage had moderate-to-good positive correlation with D value (RSpearman= 0.574, P < .001) or ADC value (RSpearman = 0.550, P < .001). No correlation between energy delivery, wattage, duration, and f value was observed (RSpearman = 0.185, P = .24; RSpearman= - 0.001, P = .99; RSpearman = 0.203, P = .20, respectively). CONCLUSION The increase in the short axis of the white zone is more likely to be affected by wattage than energy delivery. The instant post-ablation IVIM is feasible in monitoring the MWA zones since the f value in the white zones is not sensitive to changes in MWA protocols, which is promising in evaluating the instant effect of MWA.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.50
自引率
4.80%
发文量
69
审稿时长
6-12 weeks
期刊介绍: Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English. The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.
期刊最新文献
Application of deep learning and radiomics in the prediction of hematoma expansion in intracerebral hemorrhage: a fully automated hybrid approach. Diagnostic value of qualitative and quantitative enhancement parameters on contrast-enhanced mammography. Post-contrast abdominal magnetic resonance imaging of critically ill patients using compressed sensing free-breathing golden radial angle imaging. The effect of MWA protocols upon morphology and IVIM parameters of hepatic ablation zones-a preliminary in vivo animal study with an MRI-compatible microwave ablation device. Percutaneous sclerotherapy using a 4 F pigtail catheter and 40 milliliters of 5% ethanolamine oleate for symptomatic large hepatic cysts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1