桡骨远端关节外骨折掌侧锁定钢板:比较锁定螺钉与光滑锁定钉的回顾性临床研究

Pub Date : 2023-07-28 eCollection Date: 2024-04-01 DOI:10.1055/s-0043-1771338
Daniel Tordjman, Mohammad Younis, Shai Factor, Gilad Eisenberg, Franck Atlan, Jessica McBeth, Tamir Pritsch, Yishai Rosenblatt
{"title":"桡骨远端关节外骨折掌侧锁定钢板:比较锁定螺钉与光滑锁定钉的回顾性临床研究","authors":"Daniel Tordjman, Mohammad Younis, Shai Factor, Gilad Eisenberg, Franck Atlan, Jessica McBeth, Tamir Pritsch, Yishai Rosenblatt","doi":"10.1055/s-0043-1771338","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background</b>  Open reduction and internal fixation of distal radius fractures is one of the most common procedures performed in wrist surgery. The use of volar locking plate has gained increasing interest in the past decade. Epiphyseal fixation can be done either with locking screws or smooth locking pegs, with no evidence supporting the use of one rather than the other. <b>Purpose</b>  The aim of this study is to compare the stability of distal radius fixation by volar locking plate using locking screws or smooth locking pegs. <b>Methods</b>  Adult patients with A2-A3 AO fractures treated with a volar plate with locking screws only or smooth locking pegs only were retrospectively included. Radiographic assessment was performed to evaluate extra-articular parameters in the intraoperative postreduction and fixation period and after bony healing. Forty-seven distal radius fractures were included. <b>Results</b>  Twenty-four fractures had fixation with locking screws and 23 had fixation with smooth locking pegs. For both groups, all radiographic parameters measured showed a statistically significant difference between the intraoperative postreduction and fixation period and the remote postoperative period after union of the fracture ( <i>p</i>  < 0.05) attesting a slight loss of reduction. Nevertheless, there were no significant differences between the groups in radiographic extra-articular parameters. <b>Conclusion</b>  This clinical study shows that there is no difference in stability fixation between locking screws or smooth locking pegs in A2-A3 distal radius fractures. <b>Clinical Relevance</b>  The use of smooth locking pegs only for epiphyseal fixation appears to be safe in volar plating of A2-A3 distal radius fractures in adult patients and could be an alternative to locking screws. More clinical data are needed to confirm these results. <b>Level of Evidence</b>  Level III; retrospective comparative study.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10948244/pdf/","citationCount":"0","resultStr":"{\"title\":\"Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs.\",\"authors\":\"Daniel Tordjman, Mohammad Younis, Shai Factor, Gilad Eisenberg, Franck Atlan, Jessica McBeth, Tamir Pritsch, Yishai Rosenblatt\",\"doi\":\"10.1055/s-0043-1771338\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background</b>  Open reduction and internal fixation of distal radius fractures is one of the most common procedures performed in wrist surgery. The use of volar locking plate has gained increasing interest in the past decade. Epiphyseal fixation can be done either with locking screws or smooth locking pegs, with no evidence supporting the use of one rather than the other. <b>Purpose</b>  The aim of this study is to compare the stability of distal radius fixation by volar locking plate using locking screws or smooth locking pegs. <b>Methods</b>  Adult patients with A2-A3 AO fractures treated with a volar plate with locking screws only or smooth locking pegs only were retrospectively included. Radiographic assessment was performed to evaluate extra-articular parameters in the intraoperative postreduction and fixation period and after bony healing. Forty-seven distal radius fractures were included. <b>Results</b>  Twenty-four fractures had fixation with locking screws and 23 had fixation with smooth locking pegs. For both groups, all radiographic parameters measured showed a statistically significant difference between the intraoperative postreduction and fixation period and the remote postoperative period after union of the fracture ( <i>p</i>  < 0.05) attesting a slight loss of reduction. Nevertheless, there were no significant differences between the groups in radiographic extra-articular parameters. <b>Conclusion</b>  This clinical study shows that there is no difference in stability fixation between locking screws or smooth locking pegs in A2-A3 distal radius fractures. <b>Clinical Relevance</b>  The use of smooth locking pegs only for epiphyseal fixation appears to be safe in volar plating of A2-A3 distal radius fractures in adult patients and could be an alternative to locking screws. More clinical data are needed to confirm these results. <b>Level of Evidence</b>  Level III; retrospective comparative study.</p>\",\"PeriodicalId\":0,\"journal\":{\"name\":\"\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0,\"publicationDate\":\"2023-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10948244/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1771338\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1771338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景桡骨远端骨折切开复位内固定是腕部手术中最常见的手术方法之一。近十年来,掌侧锁定钢板的应用越来越受到关注。骨骺固定可以用锁定螺钉或光滑锁定钉进行,没有证据支持使用其中一种而不是另一种。目的本研究的目的是比较掌侧锁定钢板使用锁定螺钉或光滑锁定钉固定桡骨远端的稳定性。方法回顾性分析成人A2-A3型AO骨折仅用掌侧钢板加锁定螺钉或仅用光滑锁定钉治疗的病例。术中复位、固定期间及骨愈合后的关节外参数进行影像学评估。包括47例桡骨远端骨折。结果24例骨折采用锁定螺钉固定,23例采用光滑锁定钉固定。两组患者术中复位和固定期间与骨折愈合后远程术后期间的所有影像学参数测量均有统计学差异(p < 0.05),证明复位有轻微损失。然而,两组间关节外影像学参数无显著差异。结论本临床研究显示锁定螺钉与光滑锁定钉在桡骨远端A2-A3骨折的稳定固定方面无差异。在成年患者桡骨远端A2-A3骨折的掌侧钢板中,仅将光滑锁定钉用于骨骺固定似乎是安全的,可以作为锁定螺钉的替代方案。需要更多的临床数据来证实这些结果。证据等级三级;回顾性比较研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs.

Background  Open reduction and internal fixation of distal radius fractures is one of the most common procedures performed in wrist surgery. The use of volar locking plate has gained increasing interest in the past decade. Epiphyseal fixation can be done either with locking screws or smooth locking pegs, with no evidence supporting the use of one rather than the other. Purpose  The aim of this study is to compare the stability of distal radius fixation by volar locking plate using locking screws or smooth locking pegs. Methods  Adult patients with A2-A3 AO fractures treated with a volar plate with locking screws only or smooth locking pegs only were retrospectively included. Radiographic assessment was performed to evaluate extra-articular parameters in the intraoperative postreduction and fixation period and after bony healing. Forty-seven distal radius fractures were included. Results  Twenty-four fractures had fixation with locking screws and 23 had fixation with smooth locking pegs. For both groups, all radiographic parameters measured showed a statistically significant difference between the intraoperative postreduction and fixation period and the remote postoperative period after union of the fracture ( p  < 0.05) attesting a slight loss of reduction. Nevertheless, there were no significant differences between the groups in radiographic extra-articular parameters. Conclusion  This clinical study shows that there is no difference in stability fixation between locking screws or smooth locking pegs in A2-A3 distal radius fractures. Clinical Relevance  The use of smooth locking pegs only for epiphyseal fixation appears to be safe in volar plating of A2-A3 distal radius fractures in adult patients and could be an alternative to locking screws. More clinical data are needed to confirm these results. Level of Evidence  Level III; retrospective comparative study.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1