量化和比较数字牙科x光片中五种大块填充复合材料的放射不透明度-对人类识别的贡献

Daphne Azambuja Hatschbach de AQUINO , Ângela FERNANDES , Luiz Roberto Coutinho MANHÃES JUNIOR
{"title":"量化和比较数字牙科x光片中五种大块填充复合材料的放射不透明度-对人类识别的贡献","authors":"Daphne Azambuja Hatschbach de AQUINO ,&nbsp;Ângela FERNANDES ,&nbsp;Luiz Roberto Coutinho MANHÃES JUNIOR","doi":"10.1016/j.jofri.2019.03.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>: To compare the quantified radiopacity of five bulk fill composites in digital dental radiographs.</p></div><div><h3>Material and methods</h3><p>: An in-vitro observational study was performed with five dental restoration materials: I) Bulk Fill Surefil SDR+ flow® (Dentsply Sirona®, York, PA, USA), II) Bulk Fill Sonic Fill® (Kerr Corp.®, Orange, CA, USA); III) Filtek Bulk Fill flow® (3M Company®, Maplewood, MN, USA); IV) Tetric N Ceram Bulk Fill® (Ivoclar Vivadent®, Schaan, Liechtenstein); and V) Aura® (SDI Ltd.®, Victoria, Australia). Digital radiographs were taken standardly from four samples of each composite (<em>n</em> = 20). The radiopacity inherent detected in the radiographs was quantified using a 9-level aluminum scale.</p></div><div><h3>Results</h3><p>: ANOVA and Tukey's test showed statistically significant differences between the radiopacity of all bulk fill composites (<em>p</em>&lt;0.0001), except between I and IV (<em>p</em> = 1.0). Spearman's outcomes revealed that only composite I had positive moderate (rS=0.63) correlation with the respective radiopacity level in the aluminum scale (<em>p</em> = 0.027).</p></div><div><h3>Conclusion</h3><p>: Most of the bulk fill composites addressed in this study were distinguishable from each other based on their radiopacity. The identification of type and even brand of composites may be a promising task in human identification. However, this procedure remains challenging and the scientific evidence behind it is still scarce in the forensic literature.</p></div>","PeriodicalId":45371,"journal":{"name":"Journal of Forensic Radiology and Imaging","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.jofri.2019.03.002","citationCount":"1","resultStr":"{\"title\":\"Quantifying and comparing the radiopacity of five bulk fill composites in digital dental radiographs – a contribution to human identification\",\"authors\":\"Daphne Azambuja Hatschbach de AQUINO ,&nbsp;Ângela FERNANDES ,&nbsp;Luiz Roberto Coutinho MANHÃES JUNIOR\",\"doi\":\"10.1016/j.jofri.2019.03.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><p>: To compare the quantified radiopacity of five bulk fill composites in digital dental radiographs.</p></div><div><h3>Material and methods</h3><p>: An in-vitro observational study was performed with five dental restoration materials: I) Bulk Fill Surefil SDR+ flow® (Dentsply Sirona®, York, PA, USA), II) Bulk Fill Sonic Fill® (Kerr Corp.®, Orange, CA, USA); III) Filtek Bulk Fill flow® (3M Company®, Maplewood, MN, USA); IV) Tetric N Ceram Bulk Fill® (Ivoclar Vivadent®, Schaan, Liechtenstein); and V) Aura® (SDI Ltd.®, Victoria, Australia). Digital radiographs were taken standardly from four samples of each composite (<em>n</em> = 20). The radiopacity inherent detected in the radiographs was quantified using a 9-level aluminum scale.</p></div><div><h3>Results</h3><p>: ANOVA and Tukey's test showed statistically significant differences between the radiopacity of all bulk fill composites (<em>p</em>&lt;0.0001), except between I and IV (<em>p</em> = 1.0). Spearman's outcomes revealed that only composite I had positive moderate (rS=0.63) correlation with the respective radiopacity level in the aluminum scale (<em>p</em> = 0.027).</p></div><div><h3>Conclusion</h3><p>: Most of the bulk fill composites addressed in this study were distinguishable from each other based on their radiopacity. The identification of type and even brand of composites may be a promising task in human identification. However, this procedure remains challenging and the scientific evidence behind it is still scarce in the forensic literature.</p></div>\",\"PeriodicalId\":45371,\"journal\":{\"name\":\"Journal of Forensic Radiology and Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.jofri.2019.03.002\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Forensic Radiology and Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212478018301011\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Forensic Radiology and Imaging","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212478018301011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:比较5种体填充复合材料在数字牙科x线片上的量化放射不透明度。材料和方法:采用五种牙科修复材料进行体外观察研究:1)Bulk Fill Surefil SDR+ flow®(Dentsply Sirona®,York, PA, USA), II) Bulk Fill Sonic Fill®(Kerr Corp.®,Orange, CA, USA);III) Filtek Bulk Fill flow®(3M Company®,Maplewood, MN, USA);IV) N陶瓷散装填料®(Ivoclar Vivadent®,Schaan,列支敦士登);V) Aura®(SDI Ltd.®,Victoria, Australia)。从每种复合材料的4个样本中标准采集数字x线照片(n = 20)。在x线片中检测到的放射不透性用9级铝标度量化。结果:方差分析和Tukey检验显示,除I和IV之间(p = 1.0)外,所有块状填充复合材料的放射不透明度之间存在统计学差异(p<0.0001)。Spearman的结果显示,只有复合I与铝标度中各自的放射不透明度水平呈正相关(rS=0.63) (p = 0.027)。结论:本文研究的大部分填充复合材料根据其对射线的不透明程度是可以区分的。复合材料的类型甚至品牌识别可能是人类识别中一个很有前途的任务。然而,这一程序仍然具有挑战性,其背后的科学证据在法医文献中仍然很少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Quantifying and comparing the radiopacity of five bulk fill composites in digital dental radiographs – a contribution to human identification

Objectives

: To compare the quantified radiopacity of five bulk fill composites in digital dental radiographs.

Material and methods

: An in-vitro observational study was performed with five dental restoration materials: I) Bulk Fill Surefil SDR+ flow® (Dentsply Sirona®, York, PA, USA), II) Bulk Fill Sonic Fill® (Kerr Corp.®, Orange, CA, USA); III) Filtek Bulk Fill flow® (3M Company®, Maplewood, MN, USA); IV) Tetric N Ceram Bulk Fill® (Ivoclar Vivadent®, Schaan, Liechtenstein); and V) Aura® (SDI Ltd.®, Victoria, Australia). Digital radiographs were taken standardly from four samples of each composite (n = 20). The radiopacity inherent detected in the radiographs was quantified using a 9-level aluminum scale.

Results

: ANOVA and Tukey's test showed statistically significant differences between the radiopacity of all bulk fill composites (p<0.0001), except between I and IV (p = 1.0). Spearman's outcomes revealed that only composite I had positive moderate (rS=0.63) correlation with the respective radiopacity level in the aluminum scale (p = 0.027).

Conclusion

: Most of the bulk fill composites addressed in this study were distinguishable from each other based on their radiopacity. The identification of type and even brand of composites may be a promising task in human identification. However, this procedure remains challenging and the scientific evidence behind it is still scarce in the forensic literature.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Forensic Radiology and Imaging
Journal of Forensic Radiology and Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
1.70
自引率
0.00%
发文量
0
期刊最新文献
Accuracy of computed radiography in osteometry: A comparison of digital imaging techniques and the effect of magnification Explanation for the contradiction between the results of Diallo et al. (doi:10.1016/j.jofri.2018.10.001) and Winklhofer et al. (doi:10.1097/RLI.0000000000000032) in differentiating ferromagnetic from nonferromagnetic bullets by means of the dual-energy index Juvenile versus adult: A new approach for age estimation from 3-dimensional analyses of the mandibular third molar apices Stature estimation in Iranian population from x-ray measurements of femur and tibia bones Sex identification from foramen magnum using computed tomography scanning in a sample of Egyptian population
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1