利用风机辅助设备开发室外无公害区域

K. Chan, J. Tong
{"title":"利用风机辅助设备开发室外无公害区域","authors":"K. Chan, J. Tong","doi":"10.1080/1023697X.2018.1535283","DOIUrl":null,"url":null,"abstract":"ABSTRACT Vertical City Air Purification System was designed to reduce the aerosol counts at the playground next to a major traffic road. Columns with air grilles are arranged in circle to create a close loop system. Computational simulation is adopted to study three scenarios. The first simulation covers conventional wind block technology, where strong wind speed is created between columns to stop pollutants from entering the premise. However, it is observed that polluted air can enter the development from the head above. Hence, two other options are created, one with supply air directing to the centre of the development, the other with underfloor air supply. It is studied that at outlet velocity of 6.5 m/s, the underfloor system can contribute to around 40% pollution reduction using MERV13 filter, which is more than 24% better than the baseline. Traditionally, outdoor pollution mitigation deems to be contributing insignificantly. The positive simulation result marks a potential for future outdoor pollution mitigation development.","PeriodicalId":35587,"journal":{"name":"Transactions Hong Kong Institution of Engineers","volume":"25 1","pages":"220 - 228"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/1023697X.2018.1535283","citationCount":"0","resultStr":"{\"title\":\"Development of outdoor pollution free zone by fan-assisted devices\",\"authors\":\"K. Chan, J. Tong\",\"doi\":\"10.1080/1023697X.2018.1535283\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT Vertical City Air Purification System was designed to reduce the aerosol counts at the playground next to a major traffic road. Columns with air grilles are arranged in circle to create a close loop system. Computational simulation is adopted to study three scenarios. The first simulation covers conventional wind block technology, where strong wind speed is created between columns to stop pollutants from entering the premise. However, it is observed that polluted air can enter the development from the head above. Hence, two other options are created, one with supply air directing to the centre of the development, the other with underfloor air supply. It is studied that at outlet velocity of 6.5 m/s, the underfloor system can contribute to around 40% pollution reduction using MERV13 filter, which is more than 24% better than the baseline. Traditionally, outdoor pollution mitigation deems to be contributing insignificantly. The positive simulation result marks a potential for future outdoor pollution mitigation development.\",\"PeriodicalId\":35587,\"journal\":{\"name\":\"Transactions Hong Kong Institution of Engineers\",\"volume\":\"25 1\",\"pages\":\"220 - 228\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/1023697X.2018.1535283\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transactions Hong Kong Institution of Engineers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/1023697X.2018.1535283\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions Hong Kong Institution of Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/1023697X.2018.1535283","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

摘要垂直城市空气净化系统旨在减少主要交通道路旁操场的气溶胶数量。带有空气格栅的立柱呈圆形排列,形成一个闭环系统。采用计算模拟的方法对三种场景进行了研究。第一个模拟涵盖了传统的风阻技术,在风阻技术中,柱之间产生强风速度,以阻止污染物进入室内。然而,据观察,受污染的空气可以从头顶进入开发区。因此,创建了另外两个选项,一个是将送风导向开发中心,另一个是地板下送风。研究表明,在出口速度为6.5时 m/s,使用MERV13过滤器,地板下系统可以有助于减少约40%的污染,这比基线好24%以上。传统上,户外污染缓解被认为贡献不大。积极的模拟结果标志着未来户外污染缓解发展的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Development of outdoor pollution free zone by fan-assisted devices
ABSTRACT Vertical City Air Purification System was designed to reduce the aerosol counts at the playground next to a major traffic road. Columns with air grilles are arranged in circle to create a close loop system. Computational simulation is adopted to study three scenarios. The first simulation covers conventional wind block technology, where strong wind speed is created between columns to stop pollutants from entering the premise. However, it is observed that polluted air can enter the development from the head above. Hence, two other options are created, one with supply air directing to the centre of the development, the other with underfloor air supply. It is studied that at outlet velocity of 6.5 m/s, the underfloor system can contribute to around 40% pollution reduction using MERV13 filter, which is more than 24% better than the baseline. Traditionally, outdoor pollution mitigation deems to be contributing insignificantly. The positive simulation result marks a potential for future outdoor pollution mitigation development.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Transactions Hong Kong Institution of Engineers
Transactions Hong Kong Institution of Engineers Engineering-Engineering (all)
CiteScore
2.70
自引率
0.00%
发文量
22
期刊最新文献
First of its kind in Hong Kong - innovative reuse of treated effluent and enhanced energy efficiency for air-conditioning systems Class A Prediction Symposium on Debris Flow Impact Forces on Single and Dual Barriers Simulation-based quantitative methods for vehicle emissions and a CO2 charging policy Land use change in Dhaka City Corporation Area and its impact on transportation: A way forward towards integration into national policies A bibliometric study of carbon neutrality: 2001-2022
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1