Naufal Arya Pratama, L. Muqmiroh, Amillia Kartika Sari, Widiana Ferriastuti, Falentina Syivasari, Muhaimin, Sidarta Prassetyo, Cong Tien Nguyen, Phan Anh Phuong, V. Luu
{"title":"冠状动脉钙化斑块体积的筛选后投影与Intelli IP - Advanced在128层ct扫描中的比较","authors":"Naufal Arya Pratama, L. Muqmiroh, Amillia Kartika Sari, Widiana Ferriastuti, Falentina Syivasari, Muhaimin, Sidarta Prassetyo, Cong Tien Nguyen, Phan Anh Phuong, V. Luu","doi":"10.7546/ijba.2023.27.1.000878","DOIUrl":null,"url":null,"abstract":"Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05. The conclusion is that IR affects the volume value of calcified plaque.","PeriodicalId":38867,"journal":{"name":"International Journal Bioautomation","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of Calcified Plaque Volume in Coronary Arteries using Filtered Back Projection and Intelli IP Advanced at CT-scan 128 Slice\",\"authors\":\"Naufal Arya Pratama, L. Muqmiroh, Amillia Kartika Sari, Widiana Ferriastuti, Falentina Syivasari, Muhaimin, Sidarta Prassetyo, Cong Tien Nguyen, Phan Anh Phuong, V. Luu\",\"doi\":\"10.7546/ijba.2023.27.1.000878\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05. The conclusion is that IR affects the volume value of calcified plaque.\",\"PeriodicalId\":38867,\"journal\":{\"name\":\"International Journal Bioautomation\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal Bioautomation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7546/ijba.2023.27.1.000878\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Agricultural and Biological Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal Bioautomation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7546/ijba.2023.27.1.000878","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 0
摘要
钙化斑块的主要作用是增加斑块体积,从而增加冠状动脉疾病(CAD)的风险。在ct扫描中使用滤波后投影(FBP)在图像质量方面仍然存在缺陷,可能导致斑块体积计算错误。Intelli IP Advanced是日立ct扫描的迭代重建(IR)类型,与FBP相比,可以改善图像质量。本研究的目的是比较FBP和Intelli IP Advanced对冠状动脉钙化斑块体积的影响。本研究使用38例钙化斑块的冠状动脉血管样本,并使用FBP重建和Intelli IP高级算法(level 1-3)进行重建。斑块计算是自动使用宝瓶直觉版应用程序在ct扫描日立SCENARIA 128切片。本研究结果发现,FBP与Intelli IP Advanced算法重建在钙化斑块体积结果上存在显著差异(p < 0.05) (level 1-3)。然而,只有在算法重构对(Intelli IP Advanced Level 1和Level 3)中发现显著差异,p < 0.05。结论:IR影响钙化斑块的体积值。
Comparison of Calcified Plaque Volume in Coronary Arteries using Filtered Back Projection and Intelli IP Advanced at CT-scan 128 Slice
Calcified plaque has a major effect on increasing plaque volume which can increase the risk of Coronary Artery Disease (CAD). The use of Filtered Back Projection (FBP) on CT-scans still has flaws in terms of image quality that can result in errors in the calculation of plaque volume. Intelli IP Advanced is hitachi CT-scan’s Iterative Reconstruction (IR) type and can improve image quality compared to FBP. The purpose of this study is to find out the comparison of calcified plaque volume in coronary arteries using FBP and Intelli IP Advanced. This study used 38 samples of coronary artery blood vessels that had calcified plaque and reconstructed using the reconstruction of FBP and Intelli IP Advanced algorithms (Levels 1-3). Plaque calculation is done automatically using aquarius intuition edition application on CT-scan Hitachi SCENARIA 128 Slice. The results in this study found significant differences (p < 0.05) in calcified plaque volume results with the use of FBP and Intelli IP Advanced algorithm reconstruction (Levels 1-3). However, significant differences are found only in algorithm reconstruction pairs (Intelli IP Advanced Level 1 and Level 3) that have a p < 0.05. The conclusion is that IR affects the volume value of calcified plaque.