Rongrong Shen, Peiyu Zhang, Jing Liu, Rong Guo, Yawei Xu
{"title":"XIENCE PRIME依维莫司洗脱冠状动脉支架系统(EECSS)植入术后五年的临床结果","authors":"Rongrong Shen, Peiyu Zhang, Jing Liu, Rong Guo, Yawei Xu","doi":"10.15212/cvia.2023.0013","DOIUrl":null,"url":null,"abstract":"\nBackground/aim: This study was aimed at evaluating 5-year effectiveness and safety in participants after XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) implantation.\n\nMaterials and methods: From December 2013 to May 2014, 108 patients (127 lesions) were treated with the XIENCE PRIME EECSS. The entire follow-up included annual assessments for 5 years after treatment or until one of the clinical endpoints was reached. We evaluated the 5-year clinical outcomes with Kaplan-Meier analysis and the Cox regression model.\n\nResults: Nearly three-quarters of the participants were men (76.8%), and the average age was 65.6 ± 10.8 years. Bifurcation lesions accounted for 96.1% (122 lesions), and left main lesions accounted for 3.9% (five lesions), with a total count of 127 lesions. The cumulative rate of major adverse cardiac events was as follows: 1 year, 1.9%; 2 year, 4.0%; and 5 year, 10.0%. No definite or probable stent thrombosis was observed, and the rate of target lesion failure was only 3.3% over 5 years. The cumulative rate of major bleeding eventually increased to only 4.4%.\n\nConclusions: The 5-year clinical outcomes were favorable in patients treated with XIENCE PRIME EECSS, and the incidence of stent thrombosis and target lesion failure was relatively low. The incidence of major bleeding gradually increased but remained moderate.","PeriodicalId":41559,"journal":{"name":"Cardiovascular Innovations and Applications","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2023-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Five-Year Clinical Outcomes After XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) Implantation\",\"authors\":\"Rongrong Shen, Peiyu Zhang, Jing Liu, Rong Guo, Yawei Xu\",\"doi\":\"10.15212/cvia.2023.0013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\nBackground/aim: This study was aimed at evaluating 5-year effectiveness and safety in participants after XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) implantation.\\n\\nMaterials and methods: From December 2013 to May 2014, 108 patients (127 lesions) were treated with the XIENCE PRIME EECSS. The entire follow-up included annual assessments for 5 years after treatment or until one of the clinical endpoints was reached. We evaluated the 5-year clinical outcomes with Kaplan-Meier analysis and the Cox regression model.\\n\\nResults: Nearly three-quarters of the participants were men (76.8%), and the average age was 65.6 ± 10.8 years. Bifurcation lesions accounted for 96.1% (122 lesions), and left main lesions accounted for 3.9% (five lesions), with a total count of 127 lesions. The cumulative rate of major adverse cardiac events was as follows: 1 year, 1.9%; 2 year, 4.0%; and 5 year, 10.0%. No definite or probable stent thrombosis was observed, and the rate of target lesion failure was only 3.3% over 5 years. The cumulative rate of major bleeding eventually increased to only 4.4%.\\n\\nConclusions: The 5-year clinical outcomes were favorable in patients treated with XIENCE PRIME EECSS, and the incidence of stent thrombosis and target lesion failure was relatively low. The incidence of major bleeding gradually increased but remained moderate.\",\"PeriodicalId\":41559,\"journal\":{\"name\":\"Cardiovascular Innovations and Applications\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2023-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Innovations and Applications\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.15212/cvia.2023.0013\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Innovations and Applications","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.15212/cvia.2023.0013","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
摘要
背景/目的:本研究旨在评估XIENCE PRIME依维莫司洗脱冠状动脉支架系统(EECSS)植入后参与者的5年有效性和安全性。材料和方法:从2013年12月到2014年5月,108名患者(127个病灶)接受了XIENCE PRIME EECSS治疗。整个随访包括治疗后5年或达到其中一个临床终点之前的年度评估。我们使用Kaplan-Meier分析和Cox回归模型评估了5年的临床结果。结果:近四分之三的参与者是男性(76.8%),平均年龄为65.6±10.8岁。分叉病变占96.1%(122个),左主干病变占3.9%(5个),总数127个。主要心脏不良事件的累计发生率如下:1年,1.9%;2年,4.0%;5年,10.0%。未观察到明确或可能的支架血栓形成,5年内靶病变失败率仅为3.3%。大出血的累积率最终仅增加到4.4%。结论:XIENCE PRIME EECSS治疗的患者5年临床结果良好,支架血栓形成和靶病变失败的发生率相对较低。大出血的发生率逐渐增加,但仍为中度。
Five-Year Clinical Outcomes After XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) Implantation
Background/aim: This study was aimed at evaluating 5-year effectiveness and safety in participants after XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) implantation.
Materials and methods: From December 2013 to May 2014, 108 patients (127 lesions) were treated with the XIENCE PRIME EECSS. The entire follow-up included annual assessments for 5 years after treatment or until one of the clinical endpoints was reached. We evaluated the 5-year clinical outcomes with Kaplan-Meier analysis and the Cox regression model.
Results: Nearly three-quarters of the participants were men (76.8%), and the average age was 65.6 ± 10.8 years. Bifurcation lesions accounted for 96.1% (122 lesions), and left main lesions accounted for 3.9% (five lesions), with a total count of 127 lesions. The cumulative rate of major adverse cardiac events was as follows: 1 year, 1.9%; 2 year, 4.0%; and 5 year, 10.0%. No definite or probable stent thrombosis was observed, and the rate of target lesion failure was only 3.3% over 5 years. The cumulative rate of major bleeding eventually increased to only 4.4%.
Conclusions: The 5-year clinical outcomes were favorable in patients treated with XIENCE PRIME EECSS, and the incidence of stent thrombosis and target lesion failure was relatively low. The incidence of major bleeding gradually increased but remained moderate.