基于物联网的无创血糖监测系统

Sudip Paul, Shruti Jain, Bikram Majhi, Karobi Pegu, Vinayak Majhi
{"title":"基于物联网的无创血糖监测系统","authors":"Sudip Paul, Shruti Jain, Bikram Majhi, Karobi Pegu, Vinayak Majhi","doi":"10.2174/1574362417666220524085231","DOIUrl":null,"url":null,"abstract":"\n\nDiabetes is one of the most common diseases which are major public health problem worldwide. It is also the leading high risk causes of death and disability in the world. To avoid further complications due to diabetes, regular monitoring of blood glucose levels is very important. All the current method used to measure blood glucose is the invasive way, which requires finger piercing, and this invasive method is more painful and more likely to cause infection. However, patients need to be directed towards the development of non-invasive techniques to relieve pain.\n\n\n\nIn this project we use non-invasive techniques that use Near Infrared sensor for glucose level determination from fingertip without requiring needles and test strips.\n\n\n\nNear Infrared (NIR) optical signal is transmitted through one side of the fingertip and then received from its other side through which blood glucose’s molecular count is predicted by analyzing the variation in the received signal’s intensity after its reflection. And then the signal was filtered and amplified before going into the microcontroller to be displayed on an LCD display. The glucose readings were also sent to a phone via Wi-Fi and displayed through an Android application use of IoT.\n\n\n\nThe designed hardware calibrated with regression analysis by a pre calibrated conventional blood sugar machine and the derived equation is being set with respect to voltage vs Blood sugar measurement and set in the microcontroller. Finally the device is being tested with the 5 individual subjects with 10 reading each.\n\n\n\nThe device is being designed to measure the Blood Glucose in noninvasive way and it is successfully doing the same beside that the incorporation of IoT in the device give us the freedom of measuring the Blood glucose from the distance and available through the internet.\n","PeriodicalId":10868,"journal":{"name":"Current Signal Transduction Therapy","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Non-Invasive IoT-Based Glucose Level Monitoring System\",\"authors\":\"Sudip Paul, Shruti Jain, Bikram Majhi, Karobi Pegu, Vinayak Majhi\",\"doi\":\"10.2174/1574362417666220524085231\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n\\nDiabetes is one of the most common diseases which are major public health problem worldwide. It is also the leading high risk causes of death and disability in the world. To avoid further complications due to diabetes, regular monitoring of blood glucose levels is very important. All the current method used to measure blood glucose is the invasive way, which requires finger piercing, and this invasive method is more painful and more likely to cause infection. However, patients need to be directed towards the development of non-invasive techniques to relieve pain.\\n\\n\\n\\nIn this project we use non-invasive techniques that use Near Infrared sensor for glucose level determination from fingertip without requiring needles and test strips.\\n\\n\\n\\nNear Infrared (NIR) optical signal is transmitted through one side of the fingertip and then received from its other side through which blood glucose’s molecular count is predicted by analyzing the variation in the received signal’s intensity after its reflection. And then the signal was filtered and amplified before going into the microcontroller to be displayed on an LCD display. The glucose readings were also sent to a phone via Wi-Fi and displayed through an Android application use of IoT.\\n\\n\\n\\nThe designed hardware calibrated with regression analysis by a pre calibrated conventional blood sugar machine and the derived equation is being set with respect to voltage vs Blood sugar measurement and set in the microcontroller. Finally the device is being tested with the 5 individual subjects with 10 reading each.\\n\\n\\n\\nThe device is being designed to measure the Blood Glucose in noninvasive way and it is successfully doing the same beside that the incorporation of IoT in the device give us the freedom of measuring the Blood glucose from the distance and available through the internet.\\n\",\"PeriodicalId\":10868,\"journal\":{\"name\":\"Current Signal Transduction Therapy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Signal Transduction Therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1574362417666220524085231\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Signal Transduction Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1574362417666220524085231","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

糖尿病是最常见的疾病之一,也是世界范围内的主要公共卫生问题。它也是世界上死亡和残疾的主要高风险原因。为了避免糖尿病引起的进一步并发症,定期监测血糖水平非常重要。目前所有用于测量血糖的方法都是侵入性的,需要手指穿刺,而这种侵入性的方法更痛苦,更容易引起感染。然而,需要引导患者开发非侵入性技术来缓解疼痛。在这个项目中,我们使用非侵入性技术,使用近红外传感器从指尖测定血糖水平,而不需要针头和测试条。近红外(NIR)光学信号通过指尖的一侧传输,然后从指尖的另一侧接收,通过分析接收信号反射后强度的变化来预测血糖的分子计数。然后,在进入微控制器以在LCD显示器上显示之前,对信号进行滤波和放大。葡萄糖读数也通过Wi-Fi发送到手机,并通过物联网的Android应用程序显示。设计的硬件通过预先校准的传统血糖仪进行回归分析校准,推导出的方程是关于电压与血糖测量的,并在微控制器中设置。最后,对5名受试者进行了测试,每个受试者有10个读数。该设备被设计为以非侵入性的方式测量血糖,它也成功地做到了这一点,除了在设备中加入物联网让我们可以自由地从远处测量血糖并通过互联网获得。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Non-Invasive IoT-Based Glucose Level Monitoring System
Diabetes is one of the most common diseases which are major public health problem worldwide. It is also the leading high risk causes of death and disability in the world. To avoid further complications due to diabetes, regular monitoring of blood glucose levels is very important. All the current method used to measure blood glucose is the invasive way, which requires finger piercing, and this invasive method is more painful and more likely to cause infection. However, patients need to be directed towards the development of non-invasive techniques to relieve pain. In this project we use non-invasive techniques that use Near Infrared sensor for glucose level determination from fingertip without requiring needles and test strips. Near Infrared (NIR) optical signal is transmitted through one side of the fingertip and then received from its other side through which blood glucose’s molecular count is predicted by analyzing the variation in the received signal’s intensity after its reflection. And then the signal was filtered and amplified before going into the microcontroller to be displayed on an LCD display. The glucose readings were also sent to a phone via Wi-Fi and displayed through an Android application use of IoT. The designed hardware calibrated with regression analysis by a pre calibrated conventional blood sugar machine and the derived equation is being set with respect to voltage vs Blood sugar measurement and set in the microcontroller. Finally the device is being tested with the 5 individual subjects with 10 reading each. The device is being designed to measure the Blood Glucose in noninvasive way and it is successfully doing the same beside that the incorporation of IoT in the device give us the freedom of measuring the Blood glucose from the distance and available through the internet.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
18
审稿时长
>12 weeks
期刊介绍: In recent years a breakthrough has occurred in our understanding of the molecular pathomechanisms of human diseases whereby most of our diseases are related to intra and intercellular communication disorders. The concept of signal transduction therapy has got into the front line of modern drug research, and a multidisciplinary approach is being used to identify and treat signaling disorders. The journal publishes timely in-depth reviews, research article and drug clinical trial studies in the field of signal transduction therapy. Thematic issues are also published to cover selected areas of signal transduction therapy. Coverage of the field includes genomics, proteomics, medicinal chemistry and the relevant diseases involved in signaling e.g. cancer, neurodegenerative and inflammatory diseases. Current Signal Transduction Therapy is an essential journal for all involved in drug design and discovery.
期刊最新文献
Functional Roles of Long Non-coding RNAs on Stem Cell-related Pathways in Glioblastoma Antidiabetic Advancements In Silico: Pioneering Novel Heterocyclic Derivatives through Computational Design Exploring Squalene's Impact on Epidermal Thickening and Collagen Production: Molecular Docking Insights Atopic Dermatitis and Abrocitinib: Unraveling the Therapeutic Potential Atrial Natriuretic Peptide as a Biomarker and Therapeutic Target in Cancer: A Focus on Colorectal Cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1