110-330kV变压器油指标分布规律分析

IF 1.6 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Electrical Engineering & Electromechanics Pub Date : 2021-10-18 DOI:10.20998/2074-272x.2021.5.07
O. Shutenko, S. Ponomarenko
{"title":"110-330kV变压器油指标分布规律分析","authors":"O. Shutenko, S. Ponomarenko","doi":"10.20998/2074-272x.2021.5.07","DOIUrl":null,"url":null,"abstract":"Introduction. Ensuring the operational reliability of power transformers is an urgent task for the power industry in Ukraine and for most foreign countries. One of the ways to solve this problem is the correction of maximum permissible values of insulation parameters. However, such a correction is fundamentally impossible without an analysis of the laws of distribution of diagnostic indicators in the equipment with different states. The purpose of the research is to analyse the laws of distribution of the quality indicators of transformer oil with different states in 110 and 330 kV transformers. Novelty. It was found that both 330 kV autotransformers and 110 kV transformers have the displacements between the mathematical expectations of the distribution density of usable oil indicators. It caused by different service life of the analysed transformers and different values of load factors. This indicates the need to consider the influence of these factors when correcting the maximum permissible values of oil indicators. Also, the presence of displacement between the distribution densities of some indicators of usable oil in 110 kV transformers and 330 kV autotransformers has been revealed. It indicates a different intensity of oxidation reactions in transformers with different voltage class. In order to reduce the heterogeneity of initial data the procedure of statistical processing of in-service test results has been proposed as a method. This procedure combines the use of a priori information about the service life of equipment and values of load factors with the elements of statistical hypothesis testing. The results of the analysis of the distribution laws of transformer oil indicators with different states have shown that for both usable and unusable oil the values of oil indicators obey the Weibull distribution. Values of the shape and scale parameters for each of the obtained indices arrays have been obtained, as well as calculated and critical values of the goodness-of-fit criteria. Practical value. Obtained values of the distribution law parameters of the transformer oil indicators with different states, considering the service life and operating conditions allow to perform the correction of the maximum permissible values of the indicators using the statistical decision-making methods.","PeriodicalId":44198,"journal":{"name":"Electrical Engineering & Electromechanics","volume":" ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2021-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Analysis of distribution laws of transformer oil indicators in 110-330 kV transformers\",\"authors\":\"O. Shutenko, S. Ponomarenko\",\"doi\":\"10.20998/2074-272x.2021.5.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction. Ensuring the operational reliability of power transformers is an urgent task for the power industry in Ukraine and for most foreign countries. One of the ways to solve this problem is the correction of maximum permissible values of insulation parameters. However, such a correction is fundamentally impossible without an analysis of the laws of distribution of diagnostic indicators in the equipment with different states. The purpose of the research is to analyse the laws of distribution of the quality indicators of transformer oil with different states in 110 and 330 kV transformers. Novelty. It was found that both 330 kV autotransformers and 110 kV transformers have the displacements between the mathematical expectations of the distribution density of usable oil indicators. It caused by different service life of the analysed transformers and different values of load factors. This indicates the need to consider the influence of these factors when correcting the maximum permissible values of oil indicators. Also, the presence of displacement between the distribution densities of some indicators of usable oil in 110 kV transformers and 330 kV autotransformers has been revealed. It indicates a different intensity of oxidation reactions in transformers with different voltage class. In order to reduce the heterogeneity of initial data the procedure of statistical processing of in-service test results has been proposed as a method. This procedure combines the use of a priori information about the service life of equipment and values of load factors with the elements of statistical hypothesis testing. The results of the analysis of the distribution laws of transformer oil indicators with different states have shown that for both usable and unusable oil the values of oil indicators obey the Weibull distribution. Values of the shape and scale parameters for each of the obtained indices arrays have been obtained, as well as calculated and critical values of the goodness-of-fit criteria. Practical value. Obtained values of the distribution law parameters of the transformer oil indicators with different states, considering the service life and operating conditions allow to perform the correction of the maximum permissible values of the indicators using the statistical decision-making methods.\",\"PeriodicalId\":44198,\"journal\":{\"name\":\"Electrical Engineering & Electromechanics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2021-10-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Engineering & Electromechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20998/2074-272x.2021.5.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering & Electromechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2074-272x.2021.5.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 3

摘要

介绍确保电力变压器的运行可靠性是乌克兰和大多数外国电力行业的一项紧迫任务。解决这个问题的方法之一是校正绝缘参数的最大允许值。然而,如果不分析诊断指标在不同状态的设备中的分布规律,这种校正从根本上是不可能的。本研究的目的是分析110和330 kV变压器不同状态下变压器油质量指标的分布规律。新颖性研究发现,330kV自耦变压器和110kV变压器都具有在可用油指示器分布密度的数学预期之间的位移。这是由于所分析的变压器的使用寿命不同以及负载因数值不同造成的。这表明在校正机油指示器的最大允许值时需要考虑这些因素的影响。此外,还揭示了110kV变压器和330kV自耦变压器中可用油的一些指标的分布密度之间存在位移。它表明在不同电压等级的变压器中氧化反应的强度不同。为了减少初始数据的异质性,提出了在役试验结果的统计处理程序作为一种方法。该程序将有关设备使用寿命和负荷系数值的先验信息的使用与统计假设检验的元素相结合。对不同状态下变压器油指标分布规律的分析结果表明,无论是可用油还是不可用油,油指标值均服从威布尔分布。已经获得了每个所获得的索引阵列的形状和尺度参数的值,以及拟合优度标准的计算值和临界值。实用价值。得出不同状态下变压器油指标的分布规律参数值,考虑使用寿命和运行条件,可以采用统计决策方法对指标的最大允许值进行修正。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of distribution laws of transformer oil indicators in 110-330 kV transformers
Introduction. Ensuring the operational reliability of power transformers is an urgent task for the power industry in Ukraine and for most foreign countries. One of the ways to solve this problem is the correction of maximum permissible values of insulation parameters. However, such a correction is fundamentally impossible without an analysis of the laws of distribution of diagnostic indicators in the equipment with different states. The purpose of the research is to analyse the laws of distribution of the quality indicators of transformer oil with different states in 110 and 330 kV transformers. Novelty. It was found that both 330 kV autotransformers and 110 kV transformers have the displacements between the mathematical expectations of the distribution density of usable oil indicators. It caused by different service life of the analysed transformers and different values of load factors. This indicates the need to consider the influence of these factors when correcting the maximum permissible values of oil indicators. Also, the presence of displacement between the distribution densities of some indicators of usable oil in 110 kV transformers and 330 kV autotransformers has been revealed. It indicates a different intensity of oxidation reactions in transformers with different voltage class. In order to reduce the heterogeneity of initial data the procedure of statistical processing of in-service test results has been proposed as a method. This procedure combines the use of a priori information about the service life of equipment and values of load factors with the elements of statistical hypothesis testing. The results of the analysis of the distribution laws of transformer oil indicators with different states have shown that for both usable and unusable oil the values of oil indicators obey the Weibull distribution. Values of the shape and scale parameters for each of the obtained indices arrays have been obtained, as well as calculated and critical values of the goodness-of-fit criteria. Practical value. Obtained values of the distribution law parameters of the transformer oil indicators with different states, considering the service life and operating conditions allow to perform the correction of the maximum permissible values of the indicators using the statistical decision-making methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electrical Engineering & Electromechanics
Electrical Engineering & Electromechanics ENGINEERING, ELECTRICAL & ELECTRONIC-
CiteScore
2.40
自引率
50.00%
发文量
53
审稿时长
10 weeks
期刊最新文献
The mutual influence of exciting and induced currents in the circular solenoid – massive conductor system Current-voltage characteristics of single-stage semiconductor magnetic pulse generators with a distinctive structure of the conversion link in the input circuit Optimal hybrid photovoltaic distributed generation and distribution static synchronous compensators planning to minimize active power losses using adaptive acceleration coefficients particle swarm optimization algorithms Estimation of electrical resistivity of conductive materials of random shapes Modeling and research of a magnetoelectric converter for hydro and pneumo actuators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1